Chemometric Strategies for Fully Automated Interpretive Method Development in Liquid Chromatography

被引:27
作者
Bos, Tijmen S. [1 ,2 ]
Boelrijk, Jim [2 ,3 ,4 ]
Molenaar, Stef R. A. [2 ,5 ]
Veer, Brian van 't [2 ,5 ]
Niezen, Leon E. [2 ,5 ]
van Herwerden, Denice [2 ,5 ]
Samanipour, Saer [2 ,5 ]
Stoll, Dwight R. [6 ]
Forre, Patrick [3 ,4 ]
Ensing, Bernd [4 ,7 ]
Somsen, Govert W. [1 ,2 ]
Pirok, Bob W. J. [2 ,4 ,5 ,6 ]
机构
[1] Vrije Univ Amsterdam, Amsterdam Inst Mol & Life Sci, Div Bioanalyt Chem, NL-1081 HV Amsterdam, Netherlands
[2] Ctr Analyt Sci Amsterdam CASA, NL-1098 XH Amsterdam, Netherlands
[3] Univ Amsterdam, Informat Inst, AMLab, NL-1098 XH Amsterdam, Netherlands
[4] Univ Amsterdam, AI4Sci Lab, NL-1098 XH Amsterdam, Netherlands
[5] Univ Amsterdam, Vant Hoff Inst Mol Sci, Analyt Chem Grp, NL-1098 XH Amsterdam, Netherlands
[6] Gustavus Adolphus Coll, Dept Chem, St Peter, MN 56082 USA
[7] Univ Amsterdam, Vant Hoff Inst Mol Sci, Computat Chem Grp, NL-1098 XH Amsterdam, Netherlands
基金
荷兰研究理事会;
关键词
MULTIOBJECTIVE OPTIMIZATION; CLOSED-LOOP; PERFORMANCE; SPECTROMETRY; SIMULATION; SEPARATION; SERUM; TIME;
D O I
10.1021/acs.analchem.2c03160
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The majority of liquid chromatography (LC) methods are still developed in a conventional manner, that is, by analysts who rely on their knowledge and experience to make method development decisions. In this work, a novel, open-source algorithm was developed for automated and interpretive method development of LC(-mass spectrometry) separations ("AutoLC"). A closed-loop workflow was constructed that interacted directly with the LC system and ran unsupervised in an automated fashion. To achieve this, several challenges related to peak tracking, retention modeling, the automated design of candidate gradient profiles, and the simulation of chromatograms were investigated. The algorithm was tested using two newly designed method development strategies. The first utilized retention modeling, whereas the second used a Bayesianoptimization machine learning approach. In both cases, the algorithm could arrive within 4-10 iterations (i.e., sets of method parameters) at an optimum of the objective function, which included resolution and analysis time as measures of performance. Retention modeling was found to be more efficient while depending on peak tracking, whereas Bayesian optimization was more flexible but limited in scalability. We have deliberately designed the algorithm to be modular to facilitate compatibility with previous and future work (e.g., previously published data handling algorithms).
引用
收藏
页码:16060 / 16068
页数:9
相关论文
共 41 条
[1]  
[Anonymous], 2015, ACDLC GC SIMULATOR
[2]  
[Anonymous], 2015, CHROMSWORD OFF LINE
[3]   Bayesian optimization of comprehensive two-dimensional liquid chromatography separations [J].
Boelrijk, Jim ;
Pirok, Bob ;
Ensing, Bernd ;
Forre, Patrick .
JOURNAL OF CHROMATOGRAPHY A, 2021, 1659
[4]   Reducing the influence of geometry-induced gradient deformation in liquid chromatographic retention modelling [J].
Bos, Tijmen S. ;
Niezen, Leon E. ;
den Uijl, Mimi J. ;
Molenaar, Stef R. A. ;
Lege, Sascha ;
Schoenmakers, Peter J. ;
Somsen, Govert W. ;
Pirok, Bob W. J. .
JOURNAL OF CHROMATOGRAPHY A, 2021, 1635
[5]   Recent applications of chemometrics in one- and two-dimensional chromatography [J].
Bos, Tijmen S. ;
Knol, Wouter C. ;
Molenaar, Stef R. A. ;
Niezen, Leon E. ;
Schoenmakers, Peter J. ;
Somsen, Govert W. ;
Pirok, Bob W. J. .
JOURNAL OF SEPARATION SCIENCE, 2020, 43 (9-10) :1678-1727
[6]   MUSCLE: automated multi-objective evolutionary optimization of targeted LC-MS/MS analysis [J].
Bradbury, James ;
Genta-Jouve, Gregory ;
Allwood, J. William ;
Dunn, Warwick B. ;
Goodacre, Royston ;
Knowles, Joshua D. ;
He, Shan ;
Viant, Mark R. .
BIOINFORMATICS, 2015, 31 (06) :975-977
[7]   Measuring and using scanning-gradient data for use in method optimization for liquid chromatography [J].
den Uijl, Mimi J. ;
Schoenmakers, Peter J. ;
Schulte, Grace K. ;
Stoll, Dwight R. ;
van Bommel, Maarten R. ;
Pirok, Bob W. J. .
JOURNAL OF CHROMATOGRAPHY A, 2021, 1636
[8]   Geometry-independent plate height representation methods for the direct comparison of the kinetic performance of LC supports with a different size or morphology [J].
Desmet, G ;
Clicq, D ;
Gzil, P .
ANALYTICAL CHEMISTRY, 2005, 77 (13) :4058-4070
[9]   COMPUTER-SIMULATION AS A MEANS OF DEVELOPING AN OPTIMIZED REVERSED-PHASE GRADIENT-ELUTION SEPARATION [J].
DOLAN, JW ;
SNYDER, LR ;
QUARRY, MA .
CHROMATOGRAPHIA, 1987, 24 :261-276
[10]   Reducing Dilution and Analysis Time in Online Comprehensive Two-Dimensional Liquid Chromatography by Active Modulation [J].
Gargano, Andrea F. G. ;
Duffin, Mike ;
Navarro, Pablo ;
Schoenmakers, Peter J. .
ANALYTICAL CHEMISTRY, 2016, 88 (03) :1785-1793