980-Nm Diode Laser Vaporization versus Transurethral Resection of the Prostate for Benign Prostatic Hyperplasia: Randomized Controlled Study

被引:6
作者
Cetinkaya, Mehmet [1 ]
Onem, Kadir [2 ]
Rifaioglu, Mehmet Murat [3 ]
Yalcin, Veli [4 ]
机构
[1] Mugla Sitki Kocman Univ, Sch Med, Dept Urol, Mugla, Turkey
[2] Ondokuz Mayis Univ, Ondokuz Mayis Med Fac, Dept Urol, Samsun, Turkey
[3] Mustafa Kemal Univ, Fac Med, Dept Urol, Antakya, Turkey
[4] Istanbul Univ, Cerrahpasa Med Fac, Dept Urol, Istanbul, Turkey
关键词
ablation techniques; lasers; semiconductor; therapeutic use; prostatic neoplasms; surgery; transurethral resection of prostate; urinary bladder neck obstruction; urinary catheterization; PHOTOSELECTIVE VAPORIZATION; KTP LASER; ABLATION; TRIAL; HYPERTROPHY; PREVALENCE;
D O I
暂无
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: We compared the effectiveness and complications of 980-nm diode laser vaporization and transurethral resection of the prostate (TURP) in patients with benign prostatic hyperplasia (BPH). Materials and Methods: In total, 72 consecutive patients with BPH entered the study. All patients underwent general and urological evaluations. The primary outcome was improvement in the International Prostate Symptom Score (IPSS). The secondary outcomes were IPSS quality of life (QoL), maximum urinary flow rate (Qmax), residual volume, and complications. Patients were allocated randomly to the TURP and laser groups. The Ceralas HPD120, a diode laser system emitting at a wavelength of 980 nm, was used for photoselective vaporization of the prostate (PVP). TURP was performed with a monopolar 26 French resectoscope. Preoperative and operative parameters and surgical outcomes were compared. Results: In total, 36 patients in each group underwent PVP and TURP. The mean age standard deviation was 63.1 +/- 9.1 years and 64.7 +/- 10.2 years in the PVP and TURP groups, respectively. There were no statistically significant differences in age, prostate size, prostate-specific antigen concentration, Qmax, preoperative IPSS, or preoperative Qmax between the two groups. The operation duration was also similar between the groups (P =.36). The catheterization time was 1.45 +/- 0.75 and 2.63 +/- 0.49 days in the PVP and TURP groups, respectively (P <.01). The PVP group had a shorter hospital stay than the TURP group. The 3-month postoperative Qmax increased to 9.90 +/- 3.61 and 6.59 +/- 6.06 mL/s from baseline in the TURP and PVP groups, respectively; there was no difference in the increases between the groups (P =.08). The IPSS and IPSS-QoL were significantly improved with the operation (P <.01), and this improvement was similar in both groups P=.3 and P=.8, respectively. The complication rate was also similar between the two groups. Conclusions: PVP with a diode laser is as safe and effective as TURP in the treatment of BPH, and the techniques have similar complication rates and functional results. PVP has the advantage of shorter hospitalization and catheter indwelling times and no need for discontinuation of anticoagulant therapy.
引用
收藏
页码:2355 / 2361
页数:7
相关论文
共 50 条
  • [41] Comparison of Hiraoka's Transurethral Detachment Prostatectomy and Transurethral Resection of the Prostate Effects on Postoperative Erectile Function in Patients With Benign Prostatic Hyperplasia: A Prospective Randomized Controlled Study
    Pan, Chunyu
    Zhan, Yunhong
    Zhao, Yueyang
    Wu, Bin
    Bai, Song
    JOURNAL OF SEXUAL MEDICINE, 2020, 17 (11) : 2181 - 2190
  • [42] The Effect of Transurethral Resection of the Prostate on Erectile Function in Patients with Benign Prostatic Hyperplasia
    Choi, Seong Beom
    Zhao, Chen
    Park, Jong Kwan
    KOREAN JOURNAL OF UROLOGY, 2010, 51 (08) : 557 - 560
  • [43] Efficacy and safety of bipolar plasma vaporization of the prostate with "button-type" electrode compared with transurethral resection of prostate for benign prostatic hyperplasia
    Zhang Shi-ying
    Hu Hao
    Zhang Xiao-peng
    Wang Dong
    Xu Ke-xin
    Na Yan-qun
    Huang Xiao-bo
    Wang Xiao-feng
    CHINESE MEDICAL JOURNAL, 2012, 125 (21) : 3811 - 3814
  • [44] A systematic review and meta-analysis of efficacy and safety comparing greenlight laser vaporization with transurethral resection of the prostate for benign prostatic hyperplasia with prostate volume less than 80 ml
    Liu, Shangjing
    Liu, Hongquan
    Yao, Huibao
    Sun, Fengze
    Wu, Jitao
    Zhou, Zhongbao
    LASERS IN MEDICAL SCIENCE, 2023, 38 (01)
  • [45] Holmium laser enucleation versus transurethral resection of the prostate: Results from a 2-center, prospective, randomized trial in patients with obstructive benign prostatic hyperplasia
    Montorsi, F
    Naspro, R
    Salonia, A
    Suardi, N
    Briganti, A
    Zanoni, M
    Valenti, S
    Vavassori, I
    Rigatti, P
    JOURNAL OF UROLOGY, 2004, 172 (05) : 1926 - 1929
  • [46] Influence of 980-nm Diode Laser Vaporization on Sexual Function: A Short-Term Follow-Up Study
    Huang, Lin
    He, Juan
    Fan, Yongyi
    Wu, Minggui
    JOURNAL OF ENDOUROLOGY, 2018, 32 (11) : 1065 - 1070
  • [47] Randomized, controlled trial of laser vs. bipolar plasma vaporization treatment of benign prostatic hyperplasia
    Skinner, Thomas A. A.
    Leslie, Robert J.
    Steele, Stephen S.
    Nickel, J. Curtis
    CUAJ-CANADIAN UROLOGICAL ASSOCIATION JOURNAL, 2017, 11 (06): : 194 - 198
  • [48] Mean time of catheter removal in bipolar versus monopolar diathermy in transurethral resection of prostate for benign prostatic hyperplasia
    Soomro, Muhammad Imran
    Shaikh, Aamir Ali
    Soomro, Muhammad Iqbal
    Mirani, Azizullah
    Shaikh, Nisar Ahmed
    Jalbani, Malik Hussain
    RAWAL MEDICAL JOURNAL, 2021, 46 (01): : 83 - 86
  • [49] The Effect of Transurethral Resection of the Prostate on Erectile and Ejaculatory Functions in Patients with Benign Prostatic Hyperplasia
    Al Demour, Saddam H.
    Abuhamad, Mohannad
    Santarisi, Abdallah Nader
    Al-Zubi, Mohammad
    Al-Rawashdah, Samer Fathi
    Halalsheh, Omar
    Carbone, Antonio
    Pastore, Antonio Luigi
    Ahmad, Muayyad M.
    UROLOGIA INTERNATIONALIS, 2022, 106 (10) : 997 - 1004
  • [50] Thulium laser VapoResection of the prostate versus traditional transurethral resection of the prostate or transurethral plasmakinetic resection of prostate for benign prostatic obstruction: a systematic review and meta-analysis
    Deng, Zheng
    Sun, Menghao
    Zhu, Yiping
    Zhuo, Jian
    Zhao, Fujun
    Xia, Shujie
    Han, Bangmin
    Herrmann, Thomas R. W.
    WORLD JOURNAL OF UROLOGY, 2018, 36 (09) : 1355 - 1364