Metrological challenges of Synchrotron Radiation Optics

被引:18
作者
Sostero, G [1 ]
Cocco, D [1 ]
Qian, SN [1 ]
机构
[1] Sincrotrone Trieste, I-34012 Trieste, Italy
来源
OPTICAL FABRICATION AND TESTING | 1999年 / 3739卷
关键词
profilometry; optical metrology; surface metrology; x-ray optics; LTP;
D O I
10.1117/12.360158
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Modern third generation storage rings, require state-of-the-art grazing incidence x-ray optics, in order to monochromate the Synchrotron Radiation (SR) source photons, and focus them into the experimental stations. Slope error tolerances in the order of 0.5 mu Rad RMS, and surface roughness well below 5 Angstrom RMS, are frequently specified for mirrors and gratings exceeding 300 mm in length. Non-contact scanning instruments were developed, in order to characterise SR optical surfaces, of spherical and aspherical shape. Among these, the Long Trace Profiler (LTP), a double pencil slope measuring interferometer, has proved to be particularly reliable, and was adopted by several SR optics metrology laboratories. The ELETTRA soft x-rays and optics metrology laboratory, has operated an LTP since 1992. We review the basic operating principles of this instrument, and some major instrumental and environmental improvements, that were developed in order to detect slope errors lower than 1 mu Rad RMS on optical surfaces up to one metre in length. A comparison among measurements made on the same reference flat, by different interferometers (most of them were LTPs) can give some helpful indications in order to optimise the quality of measurement.
引用
收藏
页码:310 / 316
页数:7
相关论文
共 50 条
  • [41] New focusing mirror system for synchrotron radiation infrared beamlines\
    Chen, SJ
    Kuan, CK
    Perng, SY
    Wang, DJ
    Ho, HC
    Tseng, TC
    Lo, YC
    Chen, CT
    OPTICAL ENGINEERING, 2004, 43 (12) : 3077 - 3082
  • [42] Synchrotron Radiation Research on Diffraction Efficiency of Multilayer Coated Grating
    Luo Junyao
    Guo Zhi
    Huang Hao
    Ou Xin
    Zhang Xiangzhi
    ACTA OPTICA SINICA, 2021, 41 (14)
  • [43] Coherence of a near diffraction limited undulator synchrotron radiation source
    Thomas, Cyrille
    Dudin, Pavel
    Hoesch, Moritz
    OPTICS COMMUNICATIONS, 2016, 359 : 171 - 176
  • [44] A double-pass Fizeau interferometer system for measuring the figure error of large synchrotron optics
    Ludbrook, Geoff D.
    Alcock, Simon G.
    Scott, Stewart
    ADVANCES IN METROLOGY FOR X-RAY AND EUV OPTICS III, 2010, 7801
  • [45] Hard X-ray ptychography for optics characterization using a partially coherent synchrotron source
    Moxham, Thomas E. J.
    Parsons, Aaron
    Zhou, Tunhe
    Alianelli, Lucia
    Wang, Hongchang
    Laundy, David
    Dhamgaye, Vishal
    Fox, Oliver J. L.
    Sawhney, Kawal
    Korsunsky, Alexander M.
    JOURNAL OF SYNCHROTRON RADIATION, 2020, 27 : 1688 - 1695
  • [46] SHADOW3: a new version of the synchrotron X-ray optics modelling package
    del Rio, Manuel Sanchez
    Canestrari, Niccolo
    Jiang, Fan
    Cerrina, Franco
    JOURNAL OF SYNCHROTRON RADIATION, 2011, 18 : 708 - 716
  • [47] Optimizing monocapillary optics for synchrotron x-ray diffraction, fluorescence imaging, and spectroscopy applications
    Bilderback, Donald H.
    Kazimirov, Alexander
    Gillilan, Richard
    Cornaby, Sterling
    Woll, Arthur
    Zha, Chang-Sheng
    Huang, Rong
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 758 - +
  • [48] Thermally stable, silicon carbide mirror material for synchrotron x-ray beamline optics
    Robichaud, JL
    Anapol, M
    HIGH HEAT FLUX ENGINEERING III, 1996, 2855 : 147 - 152
  • [49] Time-differential Mossbauer total external reflection of synchrotron radiation
    Andreeva, MA
    PHYSICS LETTERS A, 1996, 210 (4-5) : 359 - 363
  • [50] X-ray fluorescence analysis using synchrotron radiation (SYXRF)
    Haller, M
    Knochel, A
    JOURNAL OF TRACE AND MICROPROBE TECHNIQUES, 1996, 14 (03): : 461 - 488