The position of the common facial vein in neonates: An alternate route for central venous catheter placement

被引:2
作者
van Tonder, Daniel J. [1 ]
Keough, Natalie [1 ,2 ]
van Niekerk, Martin L. [3 ]
van Schoor, Albert N. [1 ]
机构
[1] Univ Pretoria, Fac Hlth Sci, Sch Med, Dept Anat, Pretoria, South Africa
[2] Khalifa Univ, Coll Med & Hlth Sci, Dept Anat & Cellular Biol, Abu Dhabi, U Arab Emirates
[3] Univ Pretoria, Fac Hlth Sci, Sch Med, Dept Paediat Surg, Pretoria, South Africa
关键词
anatomy; catheter; facial nerve; intravenous; medical education; neonate; newborn; parenteral nutrition; surface anatomy; surgery; vascular access; veins; COMPLICATIONS; CHILDREN; ACCESS;
D O I
10.1002/ca.23685
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
Introduction We determine the location of the common facial vein (CFV) in a sample of neonates and assess the safety of this vein as an alternative access route for a central venous catheter (CVC). Materials and Methods We dissected both the left and right sides of the neck region in 24 neonatal, formalin-fixed cadavers, exposing the underlying soft tissues and neurovascular structures. We identified the CFV, which we then pinned together with the internal jugular vein, cervical branch of facial nerve, marginal mandibular branch of the facial nerve, the cricoid cartilage, brachiocephalic vein, and the mastoid and sternal attachments of the sternocleidomastoid muscle. We measured the CFV and the related pinned structures. Results In neonates, the CFV intersected the anterior border of sternocleidomastoid on average 19.53 mm (left) and 21.73 mm (right) from its sternal attachment. Conclusion We found the CFV inferior to the upper one third and just superior to half of the length of the sternocleidomastoid muscle, indicating a possible "safe-zone" where a skin incision could be made over the anteromedial border of sternocleidomastoid. The CFV is easily identified from surrounding landmarks. It could be used as a safe, alternative route for inserting a CVC if its average length (8.72 mm) and diameter (1.50 mm) are taken into account.
引用
收藏
页码:644 / 650
页数:7
相关论文
共 16 条
  • [11] Efficacy and safety of ultrasound-guided internal jugular vein catheterization in low birth weight newborn
    Montes-Tapia, Fernando
    Rodriguez-Tamez, Antonio
    Cura-Esquivel, Idalia
    Barreto-Arroyo, Itzel
    Hernandez-Garduno, Adolfo
    Rodriguez-Balderrama, Isaias
    Quero, Jose
    de la O-Cavazos, Manuel
    [J]. JOURNAL OF PEDIATRIC SURGERY, 2016, 51 (10) : 1700 - 1703
  • [12] VENTRICULO-ATRIAL SHUNT
    PUDENZ, RH
    [J]. JOURNAL OF NEUROSURGERY, 1966, 25 (05) : 602 - &
  • [13] Complications of vascular catheters in the neonatal intensive care unit
    Ramasethu, Jayashree
    [J]. CLINICS IN PERINATOLOGY, 2008, 35 (01) : 199 - +
  • [14] Vascular access in neonates
    Rocha, Gustavo
    Soares, Paulo
    Pissarra, Susana
    Soares, Henrique
    Costa, Sandra
    Henriques-Coelho, Tiago
    Guimaraes, Hercilia
    [J]. MINERVA PEDIATRICA, 2017, 69 (01) : 72 - 82
  • [15] Catheter management in neonates with bloodstream infection and a percutaneously inserted central venous catheter in situ: Removal or not?
    Tsai, Ming-Horng
    Hsu, Jen-Fu
    Lien, Reyin
    Huang, Hsuan-Rong
    Chiang, Chiao-Ching
    Chu, Shih-Ming
    Liang, Hwey-Fang
    Huang, Yhu-Chering
    [J]. AMERICAN JOURNAL OF INFECTION CONTROL, 2012, 40 (01) : 59 - 64
  • [16] CENTRAL VENOUS CATHETER PLACEMENT UTILIZING COMMON FACIAL VEIN - TECHNIQUE USEFUL IN HYPERALIMENTATION AND VENOUS-PRESSURE MONITORING
    ZUMBRO, GL
    MULLIN, MJ
    NELSON, TG
    [J]. AMERICAN JOURNAL OF SURGERY, 1973, 125 (05) : 654 - 656