Design and Performance Evaluation of a PN1 Sensor for Real-Time Measurement of Indoor Aerosol Size Distribution

被引:5
作者
Hyun, Junho [1 ]
Han, Jangseop [2 ]
Lee, Sang-Gu [1 ]
Hwang, Jungho [1 ,2 ]
机构
[1] Yonsei Univ, Grad Program Clean Technol, Seoul 03722, South Korea
[2] Yonsei Univ, Dept Mech Engn, Seoul 03722, South Korea
关键词
PN1; sensor; Virtual impactor; Corona charger; Aerosol electrometer; Particle size distribution; VIRTUAL IMPACTORS; PARTICLE SOURCES; FINE; EFFICIENCY; EXPOSURE; COOKING; MONITOR; OUTDOOR; MASS;
D O I
10.4209/aaqr.2017.08.0263
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Airborne particulate matter is an important factor in the quality of an indoor environment. In this study, a miniaturized particle sensor was developed to detect submicron-sized aerosols based on number counting. This particle number (PN) sensor was designed and fabricated for real-time measurement of total aerosol number concentration and geometric mean diameter. The sensor (hereafter called as PN1 sensor) comprised a particle-classification unit, a particle-charging unit, and a particle-detection unit. After integrating all the three units, the total number concentration and the geometric mean diameter of test aerosol particles were determined and the results were compared with those obtained using commercial instruments. First, the PN1 sensor was compared with a condensation particle counter (CPC) in lab-test. For this, different groups of monodisperse sodium chloride particles between 20 and 700 nm in diameter were used. Then the PN1 sensor was compared with a scanning mobility particle sizer (SMPS) and an aerodynamic particle sizer (APS). For this, the PN1 sensor data were obtained by varying the combination of two corona voltage and test particles (sodium chloride and polystyrene latex) size distribution. In addition to lab-test, field test was carried out with indoor aerosols in different places. The number concentration and geometric mean diameter of indoor aerosols were measured by PN1 sensor and compared with SMPS data. The number concentration was also compared with the results of CPC and Pegasor AQ Indoor (Pegasor, Finland) measurements.
引用
收藏
页码:285 / 300
页数:16
相关论文
共 28 条
[1]   Relative contribution of outdoor and indoor particle sources to indoor concentrations [J].
Abt, E ;
Suh, HH ;
Catalano, P ;
Koutrakis, P .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (17) :3579-3587
[2]  
[Anonymous], 2008011179 SAE
[3]   Comparability of Portable Nanoparticle Exposure Monitors [J].
Asbach, Christof ;
Kaminski, Heinz ;
Von Barany, Daniel ;
Kuhlbusch, Thomas A. J. ;
Monz, Christian ;
Dziurowitz, Nico ;
Pelzer, Johannes ;
Vossen, Katja ;
Berlin, Knut ;
Dietrich, Silvio ;
Goetz, Uwe ;
Kiesling, Heinz-Juergen ;
Schierl, Rudolf ;
Dahmann, Dirk .
ANNALS OF OCCUPATIONAL HYGIENE, 2012, 56 (05) :606-621
[4]   DEFINITIVE EQUATIONS FOR THE FLUID RESISTANCE OF SPHERES [J].
DAVIES, CN .
PROCEEDINGS OF THE PHYSICAL SOCIETY OF LONDON, 1945, 57 (322) :259-270
[5]   Development of a dichotomous slit nozzle virtual impactor [J].
Ding, YM ;
Koutrakis, P .
JOURNAL OF AEROSOL SCIENCE, 2000, 31 (12) :1421-1431
[6]   Design, Calibration, and Field Performance of a Miniature Diffusion Size Classifier [J].
Fierz, M. ;
Houle, C. ;
Steigmeier, P. ;
Burtscher, H. .
AEROSOL SCIENCE AND TECHNOLOGY, 2011, 45 (01) :1-10
[7]   Rationale and principle of an instrument measuring lung deposited nanoparticle surface area [J].
Fissan, H. ;
Neumann, S. ;
Trampe, A. ;
Pui, D. Y. H. ;
Shin, W. G. .
JOURNAL OF NANOPARTICLE RESEARCH, 2007, 9 (01) :53-59
[8]   Characteristics of aerosol charge neutralizers for highly charged particles [J].
Ji, JH ;
Bae, GN ;
Hwang, J .
JOURNAL OF AEROSOL SCIENCE, 2004, 35 (11) :1347-1358
[9]   Characterization of aerosol surface instruments in transition regime [J].
Jung, HJ ;
Kittelson, DB .
AEROSOL SCIENCE AND TECHNOLOGY, 2005, 39 (09) :902-911
[10]  
Kaiser K.L., 2006, ELECTROSTATIC DISCHA