In vitro assessment of combined Doppler ultrasound and CFD modeling in arterial blood flow quantification

被引:3
作者
Susanto, Swandito [1 ]
Skote, M. [1 ]
Chauhan, S. [2 ]
机构
[1] Nanyang Technol Univ, Sch Mech & Aerosp Engn, Singapore 639798, Singapore
[2] Monash Univ, Sch Mech & Aerosp Engn, Clayton, Vic 3800, Australia
关键词
Computational fluid dynamics (CFD); Doppler ultrasound; Flow quantification; In vitro experimentation; PULSATILE FLOW; VOLUME FLOW; VELOCITY; PRESSURE;
D O I
10.1016/j.flowmeasinst.2013.07.013
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Spatiotemporal quantification of the blood flow in the human vasculature has been greatly aided with the non-invasive proposition offered by Doppler ultrasound. However, relatively large deviation of the blood flow measurement from the actual value is expected, owing to a number of contributing factors. The research work expounded here attempts to ameliorate the accuracy of the blood flow output quantification by combining the Doppler measurement with the computational fluid dynamics modeling based on Navier-Stokes equation. In vitro assessment of the integrated approach was carried out with custom made phantom and probe positioning Mechatronic system. Analysis of the experimental results showed that, compared to the stand alone Doppler ultrasound measurement, the integrated model gives better accuracy in quantifying the volume flow rate. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:218 / 227
页数:10
相关论文
共 38 条
[1]   Modelling the circle of Willis to assess the effects of anatomical variations and occlusions on cerebral flows [J].
Alastruey, J. ;
Parker, K. H. ;
Peiro, J. ;
Byrd, S. M. ;
Sherwin, S. J. .
JOURNAL OF BIOMECHANICS, 2007, 40 (08) :1794-1805
[2]  
Ansys Inc, 2013, ANS FLUENT
[3]  
Antonisamy B., 2010, Biostatistics: Principles and Practice
[4]  
BEACH KW, 1996, J VASC INVEST, V2, P155
[5]   TOWARD NONINVASIVE BLOOD PRESSURE ASSESSMENT IN ARTERIES BY USING ULTRASOUND [J].
Beulen, Bart W. A. M. M. ;
Bijnens, Nathalie ;
Koutsouridis, Gregory G. ;
Brands, Peter J. ;
Rutten, Marcel C. M. ;
van de Vosse, Frans N. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2011, 37 (05) :788-797
[6]   NEW ULTRASOUND TISSUE-EQUIVALENT MATERIAL [J].
BURLEW, MM ;
MADSEN, EL ;
ZAGZEBSKI, JA ;
BANJAVIC, RA ;
SUM, SW .
RADIOLOGY, 1980, 134 (02) :517-520
[7]   Colour velocity flow measurement: In vitro validation and application to human carotid arteries [J].
Deane, CR ;
Markus, HS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (03) :447-452
[8]   Study of arterial blood pressure by a Windkessel-type model:: influence of arterial functional properties [J].
Diourté, B ;
Siché, JP ;
Comparat, V ;
Baguet, JP ;
Mallion, JM .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1999, 60 (01) :11-22
[9]  
Edmund K, 2009, P SPIE, V7372
[10]   EFFECT OF PULSATILE ARTERIAL DIAMETER VARIATIONS ON BLOOD-FLOW ESTIMATED BY DOPPLER ULTRASOUND [J].
ERIKSEN, M .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1992, 30 (01) :46-50