Investigation on the Use of Pumps in HVAC Systems for Providing Ancillary Services in Smart Grids

被引:12
作者
Wang, Huilong [1 ]
Wang, Shengwei [1 ]
Tang, Rui [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Hong Kong, Peoples R China
来源
RENEWABLE ENERGY INTEGRATION WITH MINI/MICROGRID | 2019年 / 159卷
关键词
Ancillary services; HVAC; Demand response; Smart Grid; Microgrid; CHILLER CONTROL; BUILDINGS; MODELS;
D O I
10.1016/j.egypro.2018.12.054
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The proportion of electric generation from renewable resource has been growing rapidly in recent years, especially in Microgrids in remote areas. However, the intermitted nature of the renewable energy resource has posed a great pressure on the reliability of power grids and asked a great amount of ancillary services, especially for frequency regulation (FR). Heating, ventilation, and airconditioning (HVAC) systems are promising resources to solve this challenge because they can take full use of thermal storage capacity of buildings. In this paper, a pump in HVAC system in a hotel is employed to provide the frequency regulation by adjusting its frequency to follow the automatic generation control (AGC) signals, RegA and RegD signals from Pennsylvania-New Jersey- Maryland (PJM). Performance scores are adopted to assess the control performance. In addition, the thermal capacity of the cooling coil is considered to evaluate its side-effect when providing this service. The results indicate that the pump can provide nearly 30kW total capacity with a relatively high average performance score. Moreover, the impact to indoor air temperature is almost neglectable with the thermal capacity of the cooling coil and indoor air hedging against the fluctuation of pump frequency. (C) 2019 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:219 / 224
页数:6
相关论文
共 13 条
[1]  
Ashrae, 2008, ASHRAE HDB HVAC SYST
[2]  
He Hao AK, 2013, AM CONTR C
[3]  
He Hao TM, 2012, ALL C
[4]   Electricity demand response in China: Status, feasible market schemes and pilots [J].
Li, Weilin ;
Xu, Peng ;
Lu, Xing ;
Wang, Huilong ;
Pang, Zhihong .
ENERGY, 2016, 114 :981-994
[5]   Supervisory and optimal control of central chiller plants using simplified adaptive models and genetic algorithm [J].
Ma, Zhenjun ;
Wang, Shengwei .
APPLIED ENERGY, 2011, 88 (01) :198-211
[6]   Operational Impacts of Wind Generation on California Power Systems [J].
Makarov, Yuri V. ;
Loutan, Clyde ;
Ma, Jian ;
de Mello, Phillip .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2009, 24 (02) :1039-1050
[7]   Demonstration of HVAC chiller control for power grid frequency regulation-Part 2: Discussion of results and considerations for broader deployment [J].
Su, Leo ;
Norford, Leslie K. .
SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2015, 21 (08) :1143-1153
[8]   Demonstration of HVAC chiller control for power grid frequency regulation-Part 1: Controller development and experimental results [J].
Su, Leo ;
Norford, Leslie K. .
SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2015, 21 (08) :1134-1142
[9]  
Walling R.A., 2008, ANAL WIND GENERATION
[10]   Supply-based feedback control strategy of air-conditioning systems for direct load control of buildings responding to urgent requests of smart grids [J].
Wang, Shengwei ;
Tang, Rui .
APPLIED ENERGY, 2017, 201 :419-432