摘要
Recent demonstration of highly integrated, solid-state, time-correlated single photon counting (TCSPC) systems in CMOS technology is set to provide significant increases in performance over existing bulky, expensive hardware. Arrays of single photon single photon avalanche diode (SPAD) detectors, timing channels, and signal processing can be integrated on a single silicon chip with a degree of parallelism and computational speed that is unattainable by discrete photomultiplier tube and photon counting card solutions. New multi-channel, multi-detector TCSPC sensor architectures with greatly enhanced throughput due to minimal detector transit (dead) time or timing channel dead time are now feasible. In this paper, we study the potential for future integrated, solid-state TCSPC sensors to exceed the photon pile-up limit through analytic formula and simulation. The results are validated using a 10% fill factor SPAD array and an 8-channel, 52 ps resolution time-to-digital conversion architecture with embedded lifetime estimation. It is demonstrated that pile-up insensitive acquisition is attainable at greater than 10 times the pulse repetition rate providing over 60 dB of extended dynamic range to the TCSPC technique. Our results predict future CMOS TCSPC sensors capable of live-cell transient observations in confocal scanning microscopy, improved resolution of near-infrared optical tomography systems, and fluorescence lifetime activated cell sorting. (C) 2013 AIP Publishing LLC.
引用
收藏
页数:10
相关论文
共 18 条
[1]  
[Anonymous], 2012, DIGEST TECHNICAL PAP
[2]  
BECKER W, 2005, SPRINGER SERIES CHEM, V81, P1, DOI 10.1007/3-540-28882-1
[3]   Fast-Acquisition Multispectral FLIM by Parallel TCSPC [J].
Becker, Wolfgang ;
Su, Bertram ;
Bergmann, Axel .
MULTIPHOTON MICROSCOPY IN THE BIOMEDICAL SCIENCES IX, 2009, 7183
[4]   Fluorescence lifetime standards for time and frequency domain fluorescence spectroscopy [J].
Boens, Noel ;
Qin, Wenwu ;
Basaric, Nikola ;
Hofkens, Johan ;
Ameloot, Marcel ;
Pouget, Jacques ;
Lefevre, Jean-Pierre ;
Valeur, Bernard ;
Gratton, Enrico ;
vandeVen, Martin ;
Silva, Norberto D., Jr. ;
Engelborghs, Yves ;
Willaert, Katrien ;
Sillen, Alain ;
Rumbles, Garry ;
Phillips, David ;
Visser, Antonie J. W. G. ;
van Hoek, Arie ;
Lakowicz, Joseph R. ;
Malak, Henryk ;
Gryczynski, Ignacy ;
Szabo, Arthur G. ;
Krajcarski, Don T. ;
Tamai, Naoto ;
Miura, Atsushi .
ANALYTICAL CHEMISTRY, 2007, 79 (05) :2137-2149
[5]   CORRECTION FOR PHOTON PILE-UP IN MEASUREMENT OF RADIATIVE LIFETIMES [J].
COATES, PB .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1968, 1 (08) :878-&
[6]   Ultra high-throughput single molecule spectroscopy with a 1024 pixel SPAD [J].
Colyer, Ryan A. ;
Scalia, Giuseppe ;
Villa, Federica A. ;
Guerrieri, Fabrizio ;
Tisa, Simone ;
Zappa, Franco ;
Cova, Sergio ;
Weiss, Shimon ;
Michalet, Xavier .
SINGLE MOLECULE SPECTROSCOPY AND IMAGING IV, 2011, 7905
[7]   CORRECTION METHODS FOR PHOTON PILE-UP IN LIFETIME DETERMINATION BY SINGLE-PHOTON COUNTING [J].
DAVIS, CC ;
KING, TA .
JOURNAL OF PHYSICS PART A GENERAL, 1970, 3 (01) :101-&
[8]  
Gerritsen H. C., 1997, J FLUORESC, V7, P11, DOI [10.1007/BF02764572, DOI 10.1007/BF02764572]
[9]  
Katsoulidou V, 2007, P SPIE, V6771
[10]   Video-rate fluorescence lifetime imaging camera with CMOS single-photon avalanche diode arrays and high-speed imaging algorithm [J].
Li, David D. -U. ;
Arlt, Jochen ;
Tyndall, David ;
Walker, Richard ;
Richardson, Justin ;
Stoppa, David ;
Charbon, Edoardo ;
Henderson, Robert K. .
JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (09)