Evaluation of lung tumor perfusion by dynamic contrast-enhanced MRI

被引:17
作者
Pauls, Sandra [1 ]
Mottaghy, Felix M. [2 ]
Schmidt, Stefan A. [1 ]
Krueger, Stefan [3 ]
Moeller, Peter [4 ]
Brambs, Hans-Juergen [1 ]
Wunderlich, Arthur [1 ]
机构
[1] Univ Hosp Ulm, Dept Diagnost & Intervent Radiol, D-89081 Ulm, Germany
[2] Katholieke Univ Leuven, Univ Hosp Gasthuisberg, Dept Nucl Med, B-3000 Louvain, Belgium
[3] Univ Hosp Aachen, Dept Internal Med 1, D-52057 Aachen, Germany
[4] Univ Hosp Ulm, Dept Pathol, D-89081 Ulm, Germany
关键词
Magnetic resonance imaging; (MRI); Lung tumor; Carcinoma; Perfusion;
D O I
10.1016/j.mri.2008.04.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The characterization of solid pulmonary lesions with imaging methods remains a diagnostic challenge. The ann of this study was to correlate kinetic parameters of dynamic perfusion magnetic resonance imaging (MRI) with histological tumor classification. Dynamic contrast-enhanced MRI of 31 patients With pulmonary masses (five benign lesions, 26 malignant tumors) was acquired in the tumor areas every 20 s for a mean duration of 124 s. Contrast uptake (CU) was measured by signal analysis in re-ions of interest (ROIs). The beginning and duration of CU, maximum CU (MCU, % of baseline), maximum contrast upslope (%/s) and the delay to the maximum contrast upslope (s) were calculated. All lesions were classified histologically. The beginning of CU correlated significantly with the MCU delay in all lesions (P=.033). The frequency of a plateau phase was higher in malignant tumours compared to benign lesions (P=.031). Masses with a high MCU showed more frequently a washout of contrast Medium after a plateau phase (P=.006) and a higher maximum contrast upslope (P<.001). The MCU delay time was shorter in adenocarcinoma than in squamous cell carcinoma (P=.004). These results indicate that dynamic contrast enhanced MRI might become instrumental in differentiating benign from malignant intrapulmonary tumours and distinguishing adenocarcinoma from squamous cell carcinoma. (C) 2008 Elsevier Inc. All rights reserved.
引用
收藏
页码:1334 / 1341
页数:8
相关论文
共 30 条
[1]  
Brix G, 2005, J NUCL MED, V46, P608
[2]   Clinical relevance of imaging proliferative activity in lung nodules [J].
Buck, AK ;
Hetzel, M ;
Schirrmeister, H ;
Halter, G ;
Möller, P ;
Kratochwil, C ;
Wahl, A ;
Glatting, G ;
Mottaghy, FM ;
Mattfeldt, T ;
Neumaier, B ;
Reske, SN .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 (05) :525-533
[3]  
Cai WB, 2006, J NUCL MED, V47, P2048
[4]   Breast disease: Dynamic spiral MR imaging [J].
Daniel, BL ;
Yen, YF ;
Glover, GH ;
Ikeda, DM ;
Birdwell, RL ;
Sawyer-Glover, AM ;
Black, JW ;
Plevritis, SK ;
Jeffrey, SS ;
Herfkens, RJ .
RADIOLOGY, 1998, 209 (02) :499-509
[5]   CLINICAL VENTILATION-PERFUSION SCINTIGRAPHY [J].
FAZIO, F ;
WOLLMER, P .
CLINICAL PHYSIOLOGY, 1981, 1 (04) :323-337
[7]  
GRESS H, 2001, ROFO FORTSCHR RONTG, V173, P466
[8]   Dynamic positron emission tomography with F-18 fluorodeoxyglucose imaging in differentiation of benign from malignant lung/mediastinal lesions [J].
Gupta, N ;
Gill, H ;
Graeber, G ;
Bishop, H ;
Hurst, J ;
Stephens, T .
CHEST, 1998, 114 (04) :1105-1111
[9]  
Hintze C, 2006, RADIOLOGE, V46, P251, DOI 10.1007/s00117-005-1334-7
[10]   Differentiating benign from malignant lung lesions using ''quantitative'' parameters of FDG PET images [J].
Hubner, KF ;