MRI-based treatment plan simulation and adaptation for ion radiotherapy using a classification-based approach

被引:54
|
作者
Rank, Christopher M. [1 ]
Tremmel, Christoph [1 ]
Huenemohr, Nora [1 ]
Nagel, Armin M. [2 ]
Jaekel, Oliver [1 ,3 ]
Greilich, Steffen [1 ]
机构
[1] German Canc Res Ctr, Div Med Phys Radiat Oncol, D-69120 Heidelberg, Germany
[2] German Canc Res Ctr, Div Med Phys Radiol, D-69120 Heidelberg, Germany
[3] Univ Heidelberg Hosp, Dept Radiat Oncol, D-69120 Heidelberg, Germany
关键词
Magnetic resonance imaging; Ion radiotherapy; Ion beam therapy; Treatment planning; Simulation; Plan adaptation; Pseudo CT; Classification; Ultrashort echo time; MAGNETIC-RESONANCE; ATTENUATION-CORRECTION; TISSUE SEGMENTATION; PET/MRI; RELAXATION; THERAPY; SYSTEMS; IMAGES; MODEL; BONE;
D O I
10.1186/1748-717X-8-51
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: In order to benefit from the highly conformal irradiation of tumors in ion radiotherapy, sophisticated treatment planning and simulation are required. The purpose of this study was to investigate the potential of MRI for ion radiotherapy treatment plan simulation and adaptation using a classification-based approach. Methods: Firstly, a voxelwise tissue classification was applied to derive pseudo CT numbers from MR images using up to 8 contrasts. Appropriate MR sequences and parameters were evaluated in cross-validation studies of three phantoms. Secondly, ion radiotherapy treatment plans were optimized using both MRI-based pseudo CT and reference CT and recalculated on reference CT. Finally, a target shift was simulated and a treatment plan adapted to the shift was optimized on a pseudo CT and compared to reference CT optimizations without plan adaptation. Results: The derivation of pseudo CT values led to mean absolute errors in the range of 81 - 95 HU. Most significant deviations appeared at borders between air and different tissue classes and originated from partial volume effects. Simulations of ion radiotherapy treatment plans using pseudo CT for optimization revealed only small underdosages in distal regions of a target volume with deviations of the mean dose of PTV between 1.4 - 3.1% compared to reference CT optimizations. A plan adapted to the target volume shift and optimized on the pseudo CT exhibited a comparable target dose coverage as a non-adapted plan optimized on a reference CT. Conclusions: We were able to show that a MRI-based derivation of pseudo CT values using a purely statistical classification approach is feasible although no physical relationship exists. Large errors appeared at compact bone classes and came from an imperfect distinction of bones and other tissue types in MRI. In simulations of treatment plans, it was demonstrated that these deviations are comparable to uncertainties of a target volume shift of 2 mm in two directions indicating that especially applications for adaptive ion radiotherapy are interesting.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Classification-Based Parameter Optimization Approach of the Turning Process
    Yang, Lei
    Jiang, Yibo
    Yang, Yawei
    Zeng, Guowen
    Zhu, Zongzhi
    Chen, Jiaxi
    MACHINES, 2024, 12 (11)
  • [22] A Classification-based Approach to Question Answering in Discussion Boards
    Hong, Liangjie
    Davison, Brian D.
    PROCEEDINGS 32ND ANNUAL INTERNATIONAL ACM SIGIR CONFERENCE ON RESEARCH AND DEVELOPMENT IN INFORMATION RETRIEVAL, 2009, : 171 - 178
  • [23] MRI-based treatment planning for proton radiotherapy: dosimetric validation of a deep learning-based liver synthetic CT generation method
    Liu, Yingzi
    Lei, Yang
    Wang, Yinan
    Wang, Tonghe
    Ren, Lei
    Lin, Liyong
    McDonald, Mark
    Curran, Walter J.
    Liu, Tian
    Zhou, Jun
    Yang, Xiaofeng
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (14):
  • [24] MRI-based treatment planning for liver stereotactic body radiotherapy: validation of a deep learning-based synthetic CT generation method
    Liu, Yingzi
    Lei, Yang
    Wang, Tonghe
    Kayode, Oluwatosin
    Tian, Sibo
    Liu, Tian
    Patel, Pretesh
    Curran, Walter J.
    Ren, Lei
    Yang, Xiaofeng
    BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1100):
  • [25] A classification-based fault detection and isolation scheme for the ion implanter
    Lin, Shin-Yeu
    Horng, Shih-Cheng
    IEEE TRANSACTIONS ON SEMICONDUCTOR MANUFACTURING, 2006, 19 (04) : 411 - 424
  • [26] A patch-based pseudo-CT approach for MRI-only radiotherapy in the pelvis
    Andreasen, Daniel
    Van Leemput, Koen
    Edmund, Jens M.
    MEDICAL PHYSICS, 2016, 43 (08) : 4742 - 4752
  • [27] A quantitative MRI-based approach to estimate the permeation and retention of nanomedicines in tumors
    Nomani, Alireza
    Yousefi, Siavash
    Sargsyan, Davit
    Hatefi, Arash
    JOURNAL OF CONTROLLED RELEASE, 2024, 368 : 728 - 739
  • [28] Management of traffic congestion in adaptive traffic signals using a novel classification-based approach
    Sadollah, Ali
    Gao, Kaizhou
    Zhang, Yicheng
    Zhang, Yi
    Su, Rong
    ENGINEERING OPTIMIZATION, 2019, 51 (09) : 1509 - 1528
  • [29] Multimodal MRI-based classification of migraine: using deep learning convolutional neural network
    Yang, Hao
    Zhang, Junran
    Liu, Qihong
    Wang, Yi
    BIOMEDICAL ENGINEERING ONLINE, 2018, 17
  • [30] MRI-BASED CLASSIFICATION OF BRAIN TUMOR TYPE AND GRADE USING SVM-RFE
    Zacharaki, Evangelia I.
    Wang, Sumei
    Chawla, Sanjeev
    Yoo, Dong Soo
    Wolf, Ronald
    Melhem, Elias R.
    Davatzikos, Christos
    2009 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1 AND 2, 2009, : 1035 - 1038