MRI-based treatment plan simulation and adaptation for ion radiotherapy using a classification-based approach

被引:54
|
作者
Rank, Christopher M. [1 ]
Tremmel, Christoph [1 ]
Huenemohr, Nora [1 ]
Nagel, Armin M. [2 ]
Jaekel, Oliver [1 ,3 ]
Greilich, Steffen [1 ]
机构
[1] German Canc Res Ctr, Div Med Phys Radiat Oncol, D-69120 Heidelberg, Germany
[2] German Canc Res Ctr, Div Med Phys Radiol, D-69120 Heidelberg, Germany
[3] Univ Heidelberg Hosp, Dept Radiat Oncol, D-69120 Heidelberg, Germany
关键词
Magnetic resonance imaging; Ion radiotherapy; Ion beam therapy; Treatment planning; Simulation; Plan adaptation; Pseudo CT; Classification; Ultrashort echo time; MAGNETIC-RESONANCE; ATTENUATION-CORRECTION; TISSUE SEGMENTATION; PET/MRI; RELAXATION; THERAPY; SYSTEMS; IMAGES; MODEL; BONE;
D O I
10.1186/1748-717X-8-51
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: In order to benefit from the highly conformal irradiation of tumors in ion radiotherapy, sophisticated treatment planning and simulation are required. The purpose of this study was to investigate the potential of MRI for ion radiotherapy treatment plan simulation and adaptation using a classification-based approach. Methods: Firstly, a voxelwise tissue classification was applied to derive pseudo CT numbers from MR images using up to 8 contrasts. Appropriate MR sequences and parameters were evaluated in cross-validation studies of three phantoms. Secondly, ion radiotherapy treatment plans were optimized using both MRI-based pseudo CT and reference CT and recalculated on reference CT. Finally, a target shift was simulated and a treatment plan adapted to the shift was optimized on a pseudo CT and compared to reference CT optimizations without plan adaptation. Results: The derivation of pseudo CT values led to mean absolute errors in the range of 81 - 95 HU. Most significant deviations appeared at borders between air and different tissue classes and originated from partial volume effects. Simulations of ion radiotherapy treatment plans using pseudo CT for optimization revealed only small underdosages in distal regions of a target volume with deviations of the mean dose of PTV between 1.4 - 3.1% compared to reference CT optimizations. A plan adapted to the target volume shift and optimized on the pseudo CT exhibited a comparable target dose coverage as a non-adapted plan optimized on a reference CT. Conclusions: We were able to show that a MRI-based derivation of pseudo CT values using a purely statistical classification approach is feasible although no physical relationship exists. Large errors appeared at compact bone classes and came from an imperfect distinction of bones and other tissue types in MRI. In simulations of treatment plans, it was demonstrated that these deviations are comparable to uncertainties of a target volume shift of 2 mm in two directions indicating that especially applications for adaptive ion radiotherapy are interesting.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] MRI-based treatment plan simulation and adaptation for ion radiotherapy using a classification-based approach
    Christopher M Rank
    Christoph Tremmel
    Nora Hünemohr
    Armin M Nagel
    Oliver Jäkel
    Steffen Greilich
    Radiation Oncology, 8
  • [2] MRI-based simulation of treatment plans for ion radiotherapy in the brain region
    Rank, Christopher M.
    Huenemohr, Nora
    Nagel, Armin M.
    Roethke, Matthias C.
    Jaekel, Oliver
    Greilich, Steffen
    RADIOTHERAPY AND ONCOLOGY, 2013, 109 (03) : 414 - 418
  • [3] MRI-based treatment planning with pseudo CT generated through atlas registration
    Uha, Jinsoo
    Merchant, Thomas E.
    Li, Yimei
    Li, Xingyu
    Hua, Chiaho
    MEDICAL PHYSICS, 2014, 41 (05)
  • [4] Assessment of MRI-Based Attenuation Correction for MRI-Only Radiotherapy Treatment Planning of the Brain
    Ranta, Iiro
    Teuho, Jarmo
    Linden, Jani
    Klen, Riku
    Teras, Mika
    Kapanen, Mika
    Keyrilainen, Jani
    DIAGNOSTICS, 2020, 10 (05)
  • [5] Comparative Approach of MRI-Based Brain Tumor Segmentation and Classification Using Genetic Algorithm
    Bahadure, Nilesh Bhaskarrao
    Ray, Arun Kumar
    Thethi, Har Pal
    JOURNAL OF DIGITAL IMAGING, 2018, 31 (04) : 477 - 489
  • [6] Towards abdominal MRI-based treatment planning using population-based Hounsfield units for bulk density assignment
    Hsu, Shu-Hui
    Zawisza, Irene
    O'Grady, Kyle
    Peng, Qi
    Tome, Wolfgang A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (15):
  • [7] Segmentation precision of abdominal anatomy for MRI-based radiotherapy
    Noel, Camille E.
    Zhu, Fan
    Lee, Andrew Y.
    Hu, Yanle
    Parikh, Parag J.
    MEDICAL DOSIMETRY, 2014, 39 (03) : 212 - 217
  • [8] Pseudo-CT Generation by Conditional Inference Random Forest for MRI-based Radiotherapy Treatment Planning
    Largent, Axel
    Nunes, Jean-Claude
    Saint-Jalmes, Herve
    Simon, Antoine
    Perichon, Nicolas
    Barateau, Anais
    Herve, Chloe
    Lafond, Caroline
    Greer, Peter B.
    Dowling, Jason A.
    de Crevoisier, Renaud
    Acosta, Oscar
    2017 25TH EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO), 2017, : 46 - 50
  • [9] Comparative Approach of MRI-Based Brain Tumor Segmentation and Classification Using Genetic Algorithm
    Nilesh Bhaskarrao Bahadure
    Arun Kumar Ray
    Har Pal Thethi
    Journal of Digital Imaging, 2018, 31 : 477 - 489
  • [10] Attenuation Correction for PET/MRI Using MRI-based Pseudo CT
    Wang, Tonghe
    Lei, Yang
    Dong, Xue
    Higgins, Kristin
    Liu, Tian
    Curran, Walter J.
    Mao, Hui
    Nye, Jonathon A.
    Yang, Xiaofeng
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312