Decontamination of Streptococci biofilms and Bacillus cereus spores on plastic surfaces with DC and pulsed corona discharges
被引:28
|
作者:
Kovalova, Zuzana
论文数: 0引用数: 0
h-index: 0
机构:
Comenius Univ, Fac Math Phys & Informat, Div Environm Phys, Bratislava 84248, SlovakiaComenius Univ, Fac Math Phys & Informat, Div Environm Phys, Bratislava 84248, Slovakia
Kovalova, Zuzana
[1
]
Tarabova, Katarina
论文数: 0引用数: 0
h-index: 0
机构:
Comenius Univ, Fac Math Phys & Informat, Div Biomed Phys, Bratislava 84248, SlovakiaComenius Univ, Fac Math Phys & Informat, Div Environm Phys, Bratislava 84248, Slovakia
Tarabova, Katarina
[2
]
Hensel, Karol
论文数: 0引用数: 0
h-index: 0
机构:
Comenius Univ, Fac Math Phys & Informat, Div Environm Phys, Bratislava 84248, SlovakiaComenius Univ, Fac Math Phys & Informat, Div Environm Phys, Bratislava 84248, Slovakia
Hensel, Karol
[1
]
Machala, Zdenko
论文数: 0引用数: 0
h-index: 0
机构:
Comenius Univ, Fac Math Phys & Informat, Div Environm Phys, Bratislava 84248, SlovakiaComenius Univ, Fac Math Phys & Informat, Div Environm Phys, Bratislava 84248, Slovakia
Machala, Zdenko
[1
]
机构:
[1] Comenius Univ, Fac Math Phys & Informat, Div Environm Phys, Bratislava 84248, Slovakia
[2] Comenius Univ, Fac Math Phys & Informat, Div Biomed Phys, Bratislava 84248, Slovakia
Cold air plasmas of DC and pulsed corona discharges: positive streamers and negative Trichel pulses were used for bio-decontamination of Streptococci biofilm and Bacillus cereus spores on polypropylene plastic surfaces. The reduction of bacterial population (evaluated as log(10)) in the biofilm on plastic surfaces treated by DC corona reached 2.4 logs with 10 min treatment time and 3.3 logs with 2 min treatment time with water spraying. The enhancement of plasma biocidal effects on the biofilm by electro-spraying of water through a hollow needle high-voltage electrode was investigated. No significant polarity effect was found with DC corona. Pulsed corona was demonstrated slightly more bactericidal for spores, especially in the negative polarity where the bacterial population reduction reached up to 2.2 logs at 10 min exposure time.
Yanju LI Neng ZHUHaiquan JIAJinhui WUYing YIJiancheng QI School of Environmental Science and EngineeringTianjin UniversityTianjin ChinaNational Biological Protection Engineering CenterTianjin China
论文数: 0引用数: 0
h-index: 0
Yanju LI Neng ZHUHaiquan JIAJinhui WUYing YIJiancheng QI School of Environmental Science and EngineeringTianjin UniversityTianjin ChinaNational Biological Protection Engineering CenterTianjin China