Photoacoustic Spectroscopy for the Determination of Lung Cancer Biomarkers-A Preliminary Investigation

被引:27
作者
Saalberg, Yannick [1 ,2 ]
Bruhns, Henry [1 ]
Wolff, Marcus [1 ]
机构
[1] Hamburg Univ Appl Sci, Heinrich Blasius Inst Phys Technol, Berliner Tor 21, D-20099 Hamburg, Germany
[2] Univ West Scotland, High St, Paisley PA1 2BE, Renfrew, Scotland
关键词
photoacoustic spectroscopy; PAS; volatile organic compound; VOC; IR spectra; lung cancer; biomarker; breath analysis; OPO; optical-parametric oscillator; VOLATILE ORGANIC-COMPOUNDS; NONINVASIVE DETECTION; EXHALED BREATH; MARKERS; SPECTROMETRY; ALDEHYDES; TEDLAR;
D O I
10.3390/s17010210
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
With 1.6 million deaths per year, lung cancer is one of the leading causes of death worldwide. One reason for this high number is the absence of a preventive medical examination method. Many diagnoses occur in a late cancer stage with a low survival rate. An early detection could significantly decrease the mortality. In recent decades, certain substances in human breath have been linked to certain diseases. Different studies show that it is possible to distinguish between lung cancer patients and a healthy control group by analyzing the volatile organic compounds (VOCs) in their breath. We developed a sensor based on photoacoustic spectroscopy for six of the most relevant VOCs linked to lung cancer. As a radiation source, the sensor uses an optical-parametric oscillator (OPO) in a wavelength region from 3.2 mu m to 3.5 mu m. The limits of detection for a single substance range between 5 ppb and 142 ppb. We also measured high resolution absorption spectra of the biomarkers compared to the data currently available from the National Institute of Standards and Technology (NIST) database, which is the basis of any selective spectroscopic detection. Future lung cancer screening devices could be based on the further development of this sensor.
引用
收藏
页数:9
相关论文
共 44 条
[1]  
[Anonymous], 2010, DISCRETE TIME SIGNAL
[2]  
[Anonymous], 2010, Photoacoustic IR Spectroscopy: Instrumentation, Applications and Data Analysis
[3]   Noninvasive detection of lung cancer by analysis of exhaled breath [J].
Bajtarevic, Amel ;
Ager, Clemens ;
Pienz, Martin ;
Klieber, Martin ;
Schwarz, Konrad ;
Ligor, Magdalena ;
Ligor, Tomasz ;
Filipiak, Wojciech ;
Denz, Hubert ;
Fiegl, Michael ;
Hilbe, Wolfgang ;
Weiss, Wolfgang ;
Lukas, Peter ;
Jamnig, Herbert ;
Hackl, Martin ;
Haidenberger, Alfred ;
Buszewski, Boguslaw ;
Miekisch, Wolfram ;
Schubert, Jochen ;
Amann, Anton .
BMC CANCER, 2009, 9 :348
[4]   On the use of Tedlar® bags for breath-gas sampling and analysis [J].
Beauchamp, Jonathan ;
Herbig, Jens ;
Gutmann, Rene ;
Hansel, Armin .
JOURNAL OF BREATH RESEARCH, 2008, 2 (04)
[5]  
Bell A.G., 1881, PHILOS MAG, V11, P150
[6]   Photoacoustic Spectroscopy Using a MEMS Microphone with Inter-IC Sound Digital Output [J].
Bruhns, H. ;
Marianovich, A. ;
Wolff, M. .
INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2014, 35 (12) :2292-2301
[7]  
Bruhns H., 2012, P 14 INT M CHEM SENS, P1217
[8]  
Bruhns H., 2015, SENS TRANSDUCERS, V188, P40
[9]   Identification of volatile lung cancer markers by gas chromatography-mass spectrometry: comparison with discrimination by canines [J].
Buszewski, Boguslaw ;
Ligor, Tomasz ;
Jezierski, Tadeusz ;
Wenda-Piesik, Anna ;
Walczak, Marta ;
Rudnicka, Joanna .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 404 (01) :141-146
[10]   A study of the volatile organic compounds exhaled by lung cancer cells in vitro for breath diagnosis [J].
Chen, Xing ;
Xu, Fengjuan ;
Wang, Yule ;
Pan, Yuefeng ;
Lu, Deji ;
Wang, Ping ;
Ying, Kejing ;
Chen, Enguo ;
Zhang, Weimin .
CANCER, 2007, 110 (04) :835-844