Impact of Coronary Plaque Characteristics on Late Stent Malapposition after Drug-Eluting Stent Implantation

被引:3
|
作者
Hong, Sung-Jin [1 ]
Kim, Byeong-Keuk [2 ,3 ]
Shin, Dong-Ho [2 ,3 ]
Kim, Jung-Sun [2 ,3 ]
Ko, Young-Guk [2 ,3 ]
Choi, Donghoon [2 ,3 ]
Jang, Yangsoo [2 ,3 ,4 ]
Hong, Myeong-Ki [2 ,3 ,4 ]
机构
[1] Inje Univ, Coll Med, Sanggye Paik Hosp, Dept Internal Med,Div Cardiol, Seoul, South Korea
[2] Yonsei Univ, Coll Med, Severance Cardiovasc Hosp, Div Cardiol, Seoul 03722, South Korea
[3] Yonsei Univ, Coll Med, Cardiovasc Inst, Seoul 03722, South Korea
[4] Yonsei Univ, Coll Med, Severance Biomed Sci Inst, Seoul 03722, South Korea
关键词
Drug-eluting stent; intravascular ultrasound; optical coherence tomography; OPTICAL COHERENCE TOMOGRAPHY; INTRAVASCULAR ULTRASOUND ANALYSIS; ADVERSE CLINICAL-OUTCOMES; STRUT COVERAGE; FOLLOW-UP; APPOSITION; THROMBOSIS; PREDICTORS; MECHANISMS;
D O I
10.3349/ymj.2015.56.6.1538
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To evaluate the impact of pre-procedural coronary plaque composition assessed by virtual histology intravascular ultrasound (VH-IVUS) on late stent malapposition assessed by optical coherence tomography (OCT) following drug-eluting stent (DES) implantation. Materials and Methods: The study population consisted of 121 patients (121 lesions) who underwent both pre-procedural VH-IVUS and follow-up OCT after DES implantation. The association between pre-procedural plaque composition [necrotic core (NC), dense calcium (DC), fibrotic (FT), and fibro-fatty (FF) volumes] assessed by VH-IVUS and late stent malapposition (percent malapposed struts) or strut coverage (percent uncovered struts) assessed by follow-up OCT was evaluated. Results: Pre-procedural absolute total NC, DC, FT, and FF plaque volumes were 22.9 +/- 19.0, 7.9 +/- 9.6, 63.8 +/- 33.8, and 16.5 +/- 12.4 mm(3), respectively. At 6.3 +/- 3.1 months post-intervention, percent malapposed and uncovered struts were 0.8 +/- 2.5% and 15.3 +/- 16.7%, respectively. Pre-procedural absolute total NC and DC plaque volumes were positively correlated with percent malapposed struts (r=0.44, p<0.001 and r=0.45, p<0.001, respectively), while pre-procedural absolute total FT plaque volume was weakly associated with percent malapposed struts (r=0.220, p=0.015). Pre-procedural absolute total DC plaque volume was the only independent predictor of late stent malapposition on multivariate analysis (beta=1.12, p=0.002). There were no significant correlations between pre-intervention plaque composition and percent uncovered struts. Conclusion: Pre-procedural plaque composition was associated with late stent malapposition but not strut coverage after DES implantation. Larger pre-procedural absolute total DC plaque volumes were associated with greater late stent malapposition.
引用
收藏
页码:1538 / 1544
页数:7
相关论文
共 50 条
  • [32] Late stent malapposition and marked positive vessel remodeling after sirolimus-eluting coronary stent implantation
    Zhang, F
    Qian, JY
    Ge, JB
    CHINESE MEDICAL JOURNAL, 2006, 119 (04) : 349 - 350
  • [33] Speculative Mechanisms for Very Late Stent Thrombosis After Drug-Eluting Stent Implantation
    Nakagawa, Yoshihisa
    CIRCULATION JOURNAL, 2011, 75 (04) : 779 - 780
  • [34] In-Stent Thin-Cap Fibroatheroma After Drug-Eluting Stent Implantation
    Fujii, Kenichi
    Hao, Hiroyuki
    Imanaka, Takahiro
    Kawano, Taro
    Takayama, Tadateru
    Hirayama, Atsushi
    Yamada, Tsutomu
    Ishibashi-Ueda, Hatsue
    Hirota, Seiichi
    Masuyama, Tohru
    JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (04) : 446 - 447
  • [35] Very late stent thrombosis in-late stent malapposition after sirohmus-eluting stent implantation
    Zhang, Feng
    Qian, Juying
    Ge, Junbo
    INTERNATIONAL HEART JOURNAL, 2007, 48 (05) : 591 - 596
  • [36] Pathobiology of Stent Thrombosis after Drug-Eluting Stent Implantation
    Vorpahl, Marc
    Yazdani, Saami K.
    Nakano, Masataka
    Ladich, Elena
    Kolodgie, Frank D.
    Finn, Aloke V.
    Virmani, Renu
    CURRENT PHARMACEUTICAL DESIGN, 2010, 16 (36) : 4064 - 4071
  • [37] The Incidence and Predictors of Postprocedural Incomplete Stent Apposition After Angiographically Successful Drug-Eluting Stent Implantation
    Kim, Yong-Seok
    Koo, Bon-Kwon
    Seo, Jae-Bin
    Park, Kyung Woo
    Suh, Jung-Won
    Lee, Hae-Young
    Park, Jin-Shik
    Kang, Hyun-Jae
    Cho, Young-Seok
    Chung, Woo-Young
    Chae, In-Ho
    Choi, Dong-Ju
    Kim, Hyo-Soo
    Oh, Byung-Hee
    Park, Young-Bae
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2009, 74 (01) : 58 - 63
  • [38] Major determinants for the uncovered stent struts on optical coherence tomography after drug-eluting stent implantation
    Kim, Byeong-Keuk
    Kim, Jung-Sun
    Oh, Changmyung
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (04) : 705 - 714
  • [39] Local aneurysmal dilatation mimicking stent malapposition and concurrent vulnerable plaque within neointima of normal lumen after drug-eluting stent implantation: primary new findings from optical coherence tomography
    Guo Yuan-lin
    Yang Yue-jin
    Gao Zhan
    Qian Jie
    CHINESE MEDICAL JOURNAL, 2012, 125 (06) : 1186 - 1188
  • [40] The late-phase inflammatory response after drug-eluting stent implantation
    Taguchi, Isao
    Yoneda, Shuichi
    Abe, Shichiro
    Toyoda, Shigeru
    Nasuno, Takahisa
    Nishino, Setsu
    Kageyama, Michiya
    Tokura, Michiaki
    Ogawa, Mikie
    Node, Koichi
    Inoue, Teruo
    HEART AND VESSELS, 2014, 29 (02) : 213 - 219