Impact of Coronary Plaque Characteristics on Late Stent Malapposition after Drug-Eluting Stent Implantation

被引:3
作者
Hong, Sung-Jin [1 ]
Kim, Byeong-Keuk [2 ,3 ]
Shin, Dong-Ho [2 ,3 ]
Kim, Jung-Sun [2 ,3 ]
Ko, Young-Guk [2 ,3 ]
Choi, Donghoon [2 ,3 ]
Jang, Yangsoo [2 ,3 ,4 ]
Hong, Myeong-Ki [2 ,3 ,4 ]
机构
[1] Inje Univ, Coll Med, Sanggye Paik Hosp, Dept Internal Med,Div Cardiol, Seoul, South Korea
[2] Yonsei Univ, Coll Med, Severance Cardiovasc Hosp, Div Cardiol, Seoul 03722, South Korea
[3] Yonsei Univ, Coll Med, Cardiovasc Inst, Seoul 03722, South Korea
[4] Yonsei Univ, Coll Med, Severance Biomed Sci Inst, Seoul 03722, South Korea
关键词
Drug-eluting stent; intravascular ultrasound; optical coherence tomography; OPTICAL COHERENCE TOMOGRAPHY; INTRAVASCULAR ULTRASOUND ANALYSIS; ADVERSE CLINICAL-OUTCOMES; STRUT COVERAGE; FOLLOW-UP; APPOSITION; THROMBOSIS; PREDICTORS; MECHANISMS;
D O I
10.3349/ymj.2015.56.6.1538
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To evaluate the impact of pre-procedural coronary plaque composition assessed by virtual histology intravascular ultrasound (VH-IVUS) on late stent malapposition assessed by optical coherence tomography (OCT) following drug-eluting stent (DES) implantation. Materials and Methods: The study population consisted of 121 patients (121 lesions) who underwent both pre-procedural VH-IVUS and follow-up OCT after DES implantation. The association between pre-procedural plaque composition [necrotic core (NC), dense calcium (DC), fibrotic (FT), and fibro-fatty (FF) volumes] assessed by VH-IVUS and late stent malapposition (percent malapposed struts) or strut coverage (percent uncovered struts) assessed by follow-up OCT was evaluated. Results: Pre-procedural absolute total NC, DC, FT, and FF plaque volumes were 22.9 +/- 19.0, 7.9 +/- 9.6, 63.8 +/- 33.8, and 16.5 +/- 12.4 mm(3), respectively. At 6.3 +/- 3.1 months post-intervention, percent malapposed and uncovered struts were 0.8 +/- 2.5% and 15.3 +/- 16.7%, respectively. Pre-procedural absolute total NC and DC plaque volumes were positively correlated with percent malapposed struts (r=0.44, p<0.001 and r=0.45, p<0.001, respectively), while pre-procedural absolute total FT plaque volume was weakly associated with percent malapposed struts (r=0.220, p=0.015). Pre-procedural absolute total DC plaque volume was the only independent predictor of late stent malapposition on multivariate analysis (beta=1.12, p=0.002). There were no significant correlations between pre-intervention plaque composition and percent uncovered struts. Conclusion: Pre-procedural plaque composition was associated with late stent malapposition but not strut coverage after DES implantation. Larger pre-procedural absolute total DC plaque volumes were associated with greater late stent malapposition.
引用
收藏
页码:1538 / 1544
页数:7
相关论文
共 22 条
[1]   Late incomplete stent apposition after sirolimus-eluting stent implantation - A serial intravascular ultrasound analysis [J].
Ako, J ;
Morino, Y ;
Honda, Y ;
Hassan, A ;
Sonoda, S ;
Yock, PG ;
Leon, MB ;
Moses, JW ;
Bonneau, HN ;
Fitzgerald, PJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (06) :1002-1005
[2]   Quantitative analysis of intracoronary optical coherence tomography measurements of stent strut apposition and tissue coverage [J].
Barlis, Peter ;
Dimopoulos, Konstantinos ;
Tanigawa, Jun ;
Dzielicka, Ewa ;
Ferrante, Giuseppe ;
Del Furia, Francesca ;
Di Mario, Carlo .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 141 (02) :151-156
[3]   Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation [J].
Cook, Stephane ;
Wenaweser, Peter ;
Togni, Mario ;
Billinger, Michael ;
Morger, Cyrill ;
Seiler, Christian ;
Vogel, Rolf ;
Hess, Otto ;
Meier, Bernhard ;
Windecker, Stephan .
CIRCULATION, 2007, 115 (18) :2426-2434
[4]   An optical coherence tomography study of two new generation stents with biodegradable polymer carrier, eluting paclitaxel vs. biolimus-A9 [J].
Davlouros, Periklis A. ;
Mavronasiou, Eleni ;
Xanthopoulou, Ioanna ;
Karantalis, Vasileios ;
Tsigkas, Grigorios ;
Hahalis, George ;
Alexopoulos, Dimitrios .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2012, 157 (03) :341-346
[5]   Examination of the In Vivo Mechanisms of Late Drug-Eluting Stent Thrombosis Findings From Optical Coherence Tomography and Intravascular Ultrasound Imaging [J].
Guagliumi, Giulio ;
Sirbu, Vasile ;
Musumeci, Giuseppe ;
Gerber, Robert ;
Biondi-Zoccai, Giuseppe ;
Ikejima, Hideyuki ;
Ladich, Elena ;
Lortkipanidze, Nikoloz ;
Matiashvili, Aleksandre ;
Valsecchi, Orazio ;
Virmani, Renu ;
Stone, Gregg W. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (01) :12-20
[6]   Incidence, Mechanisms, Predictors, and Clinical Impact of Acute and Late Stent Malapposition After Primary Intervention in Patients With Acute Myocardial Infarction An Intravascular Ultrasound Substudy of the Harmonizing Outcomes With Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) Trial [J].
Guo, Ning ;
Maehara, Akiko ;
Mintz, Gary S. ;
He, Yong ;
Xu, Kai ;
Wu, Xiaofan ;
Lansky, Alexandra J. ;
Witzenbichler, Bernhard ;
Guagliumi, Giulio ;
Brodie, Bruce ;
Kellett, Mirle A., Jr. ;
Dressler, Ovidiu ;
Parise, Helen ;
Mehran, Roxana ;
Stone, Gregg W. .
CIRCULATION, 2010, 122 (11) :1077-1084
[7]   Vascular Tissue Reaction to Acute Malapposition in Human Coronary Arteries Sequential Assessment With Optical Coherence Tomography [J].
Gutierrez-Chico, Juan Luis ;
Wykrzykowska, Joanna ;
Nueesch, Eveline ;
van Geuns, Robert Jan ;
Koch, Karel T. ;
Koolen, Jacques J. ;
di Mario, Carlo ;
Windecker, Stephan ;
van Es, Gerrit-Anne ;
Gobbens, Pierre ;
Jueni, Peter ;
Regar, Evelyn ;
Serruys, Patrick W. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (01) :20-U81
[8]   Late stent malapposition risk is higher after drug-eluting stent compared with bare-metal stent implantation and associates with late stent thrombosis [J].
Hassan, Ayman K. M. ;
Bergheanu, Sandrin C. ;
Stijnen, Theo ;
van der Hoeven, Bas L. ;
Snoep, Jaapjan D. ;
Plevier, Josepha W. M. ;
Schalij, Martin J. ;
Jukema, J. Wouter .
EUROPEAN HEART JOURNAL, 2010, 31 (10) :1172-1180
[9]   Late stent malapposition after drug-eluting stent implantation - An intravascular ultrasound analysis with long-term follow-up [J].
Hong, MK ;
Mintz, GS ;
Lee, CW ;
Park, DW ;
Park, KM ;
Lee, BK ;
Kim, YH ;
Song, JM ;
Han, KH ;
Kang, DH ;
Cheong, SS ;
Song, JK ;
Kim, JJ ;
Park, SW ;
Park, SJ .
CIRCULATION, 2006, 113 (03) :414-419
[10]   Relation between poststenting peristent plaque components and late stent malapposition after drug-eluting stent implantation: Virtual histology-intravascular ultrasound analysis [J].
Hong, Young Joon ;
Jeong, Myung Ho ;
Choi, Yun Ha ;
Song, Jin A. ;
Jang, Su Young ;
Yoo, Jong Hyun ;
Song, Ji Eun ;
Lee, Ki Hong ;
Yamanaka, Futoshi ;
Lee, Min Goo ;
Park, Keun Ho ;
Sim, Doo Sun ;
Yoon, Nam Sik ;
Yoon, Hyun Ju ;
Kim, Kye Hun ;
Park, Hyung Wook ;
Kim, Ju Han ;
Ahn, Youngkeun ;
Cho, Jeong Gwan ;
Park, Jong Chun ;
Kang, Jung Chaee .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 167 (05) :1882-1887