Design of a Cyclic Pressure Bioreactor for the Ex Vivo Study of Aortic Heart Valves

被引:1
|
作者
Schipke, Kimberly J. [1 ]
To, S. D. Filip [1 ]
Warnock, James N. [1 ]
机构
[1] Mississippi State Univ, Dept Agr & Biol Engn, Mississippi State, MS 39762 USA
来源
关键词
Bioengineering; Issue; 54; Mechanobiology; Bioreactor; Aortic Heart Valve; Organ Culture; POSTOPERATIVE ARRHYTHMIAS; DISEASE; SURGERY;
D O I
10.3791/3316
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The aortic valve, located between the left ventricle and the aorta, allows for unidirectional blood flow, preventing backflow into the ventricle. Aortic valve leaflets are composed of interstitial cells suspended within an extracellular matrix (ECM) and are lined with an endothelial cell monolayer. The valve withstands a harsh, dynamic environment and is constantly exposed to shear, flexion, tension, and compression. Research has shown calcific lesions in diseased valves occur in areas of high mechanical stress as a result of endothelial disruption or interstitial matrix damage(1-3). Hence, it is not surprising that epidemiological studies have shown high blood pressure to be a leading risk factor in the onset of aortic valve disease(4). The only treatment option currently available for valve disease is surgical replacement of the diseased valve with a bioprosthetic or mechanical valve(5). Improved understanding of valve biology in response to physical stresses would help elucidate the mechanisms of valve pathogenesis. In turn, this could help in the development of non-invasive therapies such as pharmaceutical intervention or prevention. Several bioreactors have been previously developed to study the mechanobiology of native or engineered heart valves(6-9). Pulsatile bioreactors have also been developed to study a range of tissues including cartilage(10), bone(11) and bladder(12). The aim of this work was to develop a cyclic pressure system that could be used to elucidate the biological response of aortic valve leaflets to increased pressure loads. The system consisted of an acrylic chamber in which to place samples and produce cyclic pressure, viton diaphragm solenoid valves to control the timing of the pressure cycle, and a computer to control electrical devices. The pressure was monitored using a pressure transducer, and the signal was conditioned using a load cell conditioner. A LabVIEW program regulated the pressure using an analog device to pump compressed air into the system at the appropriate rate. The system mimicked the dynamic transvalvular pressure levels associated with the aortic valve; a saw tooth wave produced a gradual increase in pressure, typical of the transvalvular pressure gradient that is present across the valve during diastole, followed by a sharp pressure drop depicting valve opening in systole. The LabVIEW program allowed users to control the magnitude and frequency of cyclic pressure. The system was able to subject tissue samples to physiological and pathological pressure conditions. This device can be used to increase our understanding of how heart valves respond to changes in the local mechanical environment.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Design of a sterile organ culture system for the ex vivo study of aortic heart valves
    Warnock, JN
    Konduri, S
    He, ZM
    Yoganathan, AP
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (05): : 857 - 861
  • [2] An Ex Vivo Study of the Biological Properties of Porcine Aortic Valves in Response to Circumferential Cyclic Stretch
    Kartik Balachandran
    Suchitra Konduri
    Philippe Sucosky
    Hanjoong Jo
    Ajit P. Yoganathan
    Annals of Biomedical Engineering, 2006, 34 : 1655 - 1665
  • [3] An ex vivo study of the biological properties of porcine aortic valves in response to circumferential cyclic stretch
    Balachandran, Kartik
    Konduri, Suchitra
    Sucosky, Philippe
    Jo, Hanjoong
    Yoganathan, Ajit P.
    ANNALS OF BIOMEDICAL ENGINEERING, 2006, 34 (11) : 1655 - 1665
  • [4] Automated Aortic Pressure Regulation in ex vivo Heart Perfusion
    Xin, Liming
    Yao, Weiran
    Peng, Yan
    Qi, Naiming
    Badiwala, Mitesh
    Sun, Yu
    2019 INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2019, : 4241 - 4246
  • [5] Normal physiological conditions maintain the biological characteristics of porcine aortic heart valves:: An Ex vivo organ culture study
    Konduri, S
    Xing, Y
    Warnock, JN
    He, ZM
    Yoganathan, AP
    ANNALS OF BIOMEDICAL ENGINEERING, 2005, 33 (09) : 1158 - 1166
  • [6] Normal Physiological Conditions Maintain the Biological Characteristics of Porcine Aortic Heart Valves: An Ex Vivo Organ Culture Study
    Suchitra Konduri
    Yun Xing
    James N. Warnock
    Zhaoming He
    Ajit P. Yoganathan
    Annals of Biomedical Engineering, 2005, 33 : 1158 - 1166
  • [7] Controlled cyclic stretch bioreactor for tissue-engineered heart valves
    Syedain, Zeeshan H.
    Tranquillo, Robert T.
    BIOMATERIALS, 2009, 30 (25) : 4078 - 4084
  • [8] The influence of bicuspid aortic valves on the dynamic pressure distribution in the ascending aorta: a porcine ex vivo model
    Juraszek, Andrzej
    Dziodzio, Tomasz
    Stoiber, Martin
    Fechtig, Daniel
    Gschlad, Verena
    Aigner, Philipp
    Czerny, Martin
    Schima, Heinrich
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2014, 46 (03) : 349 - 355
  • [9] IN VITRO TESTING OF LIVING AORTIC HEART VALVES USING A PULSATILE BIOREACTOR
    Sierad, Leslie N.
    Simionescu, Dan
    Proceedings of the 3rd Frontiers in Biomedical Devices Conference - 2008, 2008, : 89 - 90
  • [10] A study of extracellular matrix remodeling in aortic heart valves using a novel biaxial stretch bioreactor
    Lei, Ying
    Masjedi, Shirin
    Ferdous, Zannatul
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2017, 75 : 351 - 358