Calibrations of a high-suction tensiometer

被引:31
作者
Lourenco, S. D. N. [1 ]
Gallipoli, D. [3 ]
Toll, D. G. [2 ]
Augarde, C. E. [2 ]
Evans, F. D. [4 ]
Medero, G. M. [5 ]
机构
[1] Geotech Observat Ltd, Egham, Surrey, England
[2] Univ Durham, Sch Engn, Durham DH1 3HP, England
[3] Univ Glasgow, Dept Civil Engn, Glasgow G12 8QQ, Lanark, Scotland
[4] Controls Testing Equipment Ltd, Wykeham Farrance Div, Tring, Italy
[5] Heriot Watt Univ, Sch Built Environm, Edinburgh, Midlothian, Scotland
来源
GEOTECHNIQUE | 2008年 / 58卷 / 08期
基金
英国工程与自然科学研究理事会;
关键词
laboratory equipment; laboratory testing; partial saturation; suction;
D O I
10.1680/geot.2008.58.8.659
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
High-suction tensiometers are able to measure suctions up to 2 MPa. Direct calibration at such high suctions requires the imposition of negative water pressures, which are difficult to achieve using facilities commonly available in soil mechanics laboratories. For this reason, tensiometers are usually calibrated in the positive pressure range, and such calibration is subsequently extrapolated to negative pressures. This paper examines different experimental techniques to assess the accuracy of such extrapolation. Any error in the calibration process would be directly reflected in the measured values of suction, and might be particularly significant (in relative terms) for the measurement of low suctions. In addition, the results of this study show that calibration in the positive range is affected both by the physical configuration of the tensiometer during calibration and by aspects of its design. The paper concludes that linear extrapolation of the calibration from the positive to the negative range is sufficiently accurate provided that calibration is done under conditions that closely match the conditions in which the tensiometer will be used. Owing to structural differences between tensiometers, and also to suction-induced 'calibration hysteresis', at least one check on the accuracy of the extrapolated calibration equation over a range of negative pressure should be performed, even if at low values of suction.
引用
收藏
页码:659 / 668
页数:10
相关论文
共 23 条
[1]   INFLUENCE OF PORE-WATER TENSION ON STRENGTH OF CLAY [J].
BISHOP, AW ;
KUMAPLEY, NK ;
ELRUWAYIH, A .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 1975, 278 (1286) :511-+
[2]  
DONOGHUE M, 2006, PERFORMANCE EFFECTS
[3]   Use of the tensile strength of water for the direct measurement of high soil suction [J].
Guan, Y ;
Fredlund, DG .
CANADIAN GEOTECHNICAL JOURNAL, 1997, 34 (04) :604-614
[4]   A SIMPLE PIEZOMETER PROBE FOR THE ROUTINE MEASUREMENT OF PORE PRESSURE IN TRIAXIAL TESTS ON SATURATED SOILS [J].
HIGHT, DW .
GEOTECHNIQUE, 1982, 32 (04) :396-401
[5]  
JAQUIN PA, 2008, GEOTECHNIQU IN PRESS
[6]   The development of a suction control system for a triaxial apparatus [J].
Jotisankasa, A. ;
Coop, M. ;
Ridley, A. .
GEOTECHNICAL TESTING JOURNAL, 2007, 30 (01) :69-75
[7]  
Jotisankasa A., 2005, THESIS IMPERIAL COLL
[8]  
Lourenco S, 2007, SPRINGER PROC PHYS, V112, P95
[9]  
LOURENO SDN, 2006, P 14 INT C UNS SOILS, V2, P1875
[10]   Mini suction probe for matric suction measurements [J].
Meilani, I ;
Rahardjo, H ;
Leong, EC ;
Fredlund, DG .
CANADIAN GEOTECHNICAL JOURNAL, 2002, 39 (06) :1427-1432