MR Imaging of Metal-on-Metal Hip Prostheses

被引:10
作者
Campe, Carson B. [1 ]
Palmer, William E. [1 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Div Musculoskeletal Imaging, Boston, MA 02114 USA
关键词
MR imaging; Metal artifact reduction; Hip arthroplasty; Metal-on-metal; Pseudotumor; RESURFACING ARTHROPLASTY; INFLAMMATORY PSEUDOTUMOR; ARTIFACT REDUCTION; PERIPROSTHETIC OSTEOLYSIS; ASYMPTOMATIC PATIENTS; JOINT REPLACEMENT; EARLY FAILURE; FOLLOW-UP; IMPLANTS; COMPONENTS;
D O I
10.1016/j.mric.2012.09.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Metal-on-metal (MoM) hip arthroplasty was expected to provide benefits over metal-on-polyethylene systems. After widespread placement of MoM implants, outcomes have been disappointing. MoM implants are associated with higher serum levels of metal ions, adverse periarticular soft tissue reactions, and increased long-term failure rates. In light of these findings, it is crucial that patients with MoM implants be closely monitored for adverse effects. MR imaging is ideally suited for assessment of these patients and complements standard clinical evaluation and laboratory testing. This article reviews the background of MoM implants, emerging data on complications, strategies for using MR imaging, and MR imaging findings in patients with reaction to metal.
引用
收藏
页码:155 / +
页数:15
相关论文
共 68 条
[1]   SEMAC-VAT and MSVAT-SPACE Sequence Strategies for Metal Artifact Reduction in 1.5T Magnetic Resonance Imaging [J].
Ai, Tao ;
Padua, Abraham ;
Goerner, Frank ;
Nittka, Mathias ;
Gugala, Zbigniew ;
Jadhav, Siddharth ;
Trelles, Miguel ;
Johnson, Raleigh F. ;
Lindsey, Ronald W. ;
Li, Xiaoming ;
Runge, Val M. .
INVESTIGATIVE RADIOLOGY, 2012, 47 (05) :267-276
[2]  
[Anonymous], 6 NAT JOINT REG ENGL
[3]  
Bal B Sonny, 2008, Instr Course Lect, V57, P223
[4]   Twenty-five-year survivorship of two thousand consecutive primary Charnley total hip replacements - Factors affecting survivorship of acetabular and femoral components [J].
Berry, DJ ;
Harmsen, WS ;
Cabanela, ME ;
Morrey, BF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (02) :171-177
[5]   The Epidemiology of Bearing Surface Usage in Total Hip Arthroplasty in the United States [J].
Bozic, Kevin J. ;
Kurtz, Steven ;
Lau, Edmund ;
Ong, Kevin ;
Chiu, Vanessa ;
Vail, Thomas P. ;
Rubash, Harry E. ;
Berry, Daniel J. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (07) :1614-1620
[6]  
Butts K, 2002, P INT SOC MAG RESON, P10
[7]   New MR Imaging Methods for Metallic Implants in the Knee: Artifact Correction and Clinical Impact [J].
Chen, Christina A. ;
Chen, Weitian ;
Goodman, Stuart B. ;
Hargreaves, Brian A. ;
Koch, Kevin M. ;
Lu, Wenmaio ;
Brau, Anja C. ;
Draper, Christine E. ;
Delp, Scott L. ;
Gold, Garry E. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (05) :1121-1127
[8]   TOTAL INHOMOGENEITY CORRECTION INCLUDING CHEMICAL-SHIFTS AND SUSCEPTIBILITY BY VIEW ANGLE TILTING [J].
CHO, ZH ;
KIM, DJ ;
KIM, YK .
MEDICAL PHYSICS, 1988, 15 (01) :7-11
[9]   Inflammatory pseudotumor associated with femoral nerve palsy following metal-on-metal resurfacing of the hip [J].
Clayton, Robert A. E. ;
Beggs, Ian ;
Salter, Donald M. ;
Grant, M. Helen ;
Patton, James T. ;
Porter, Daniel E. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (09) :1988-1993
[10]  
Counsell A, 2008, ACTA ORTHOP BELG, V74, P870