Two-body wear and surface hardness of occlusal splint materials

被引:17
|
作者
Gibreel, Mona [1 ,2 ]
Perea-Lowery, Leila [1 ,2 ]
Vallittu, Pekka K. [1 ,2 ,3 ]
Garoushi, Sufyan [1 ,2 ]
Lassila, Lippo [1 ,2 ]
机构
[1] Univ Turku, Dept Biomat Sci, Inst Dent, Itainen Pitkakatu 48, FI-20520 Turku, Finland
[2] Univ Turku, Turku Clin Biomat Ctr TCBC, Inst Dent, Itainen Pitkakatu 48, FI-20520 Turku, Finland
[3] City Turku, Welf Div, Lemminkaisenkatu 2, FI-20520 Turku, Finland
关键词
Two-body wear; Occlusal splints; 3D printing; CAD/CAM; Surface hardness; IN-VITRO WEAR; TEMPOROMANDIBULAR DISORDER; MECHANICAL-PROPERTIES; FLEXURAL PROPERTIES; SOFT; CHALLENGES; MANAGEMENT; APPLIANCES; RESISTANCE; POLYMERS;
D O I
10.4012/dmj.2022-100
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this in vitro study was to evaluate the wear and surface hardness of nine materials for conventional manufacturing, subtractive milling, and 3D printing of occlusal splints, as well as to evaluate the differences in wear and surface hardness between rigid and flexible 3D-printed occlusal splint materials. Two-body wear and Vickers hardness tests were performed. The vertical wear depth and Vickers hardness values were statistically analyzed. Vertical wear depth and surface hardness values were statistically significant among the investigated materials (p<0.05). The lowest vertical wear depth was observed for the heat-cured resin (27.5 +/- 2.4 mu m), PMMA-based milled material (30.5 +/- 2.8 mu m), and autopolymerizing resin (36.7 +/- 6.3 mu m), with no statistical difference (p<0.05). Flexible 3D-printed and CAD-CAM milled polycarbonate-based splint materials displayed lower surface hardness and higher wear than the PMMA-based materials. PMMA-based splint materials displayed the most consistent surface hardness and wear resistance regardless of the manufacturing technology.
引用
收藏
页码:916 / 922
页数:7
相关论文
共 50 条
  • [31] Wear resistance and flexural properties of low force SLA- and DLP-printed splint materials in different printing orientations: An in vitro study
    Simeon, Philipp
    Unkovskiy, Alexey
    Sarmadi, Bardia Saadat
    Nicic, Robert
    Koch, Petra Julia
    Beuer, Florian
    Schmidt, Franziska
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2024, 152
  • [32] Influence of different surface treatments on two-body wear and fracture load of monolithic CAD/CAM ceramics
    Wiedenmann, Felicitas
    Boehm, Denise
    Eichberger, Marlis
    Edelhoff, Daniel
    Stawarczyk, Bogna
    CLINICAL ORAL INVESTIGATIONS, 2020, 24 (09) : 3049 - 3060
  • [33] Wear, strength, modulus and hardness of CAD/CAM restorative materials
    Lawson, Nathaniel C.
    Bansal, Ritika
    Burgess, John O.
    DENTAL MATERIALS, 2016, 32 (11) : E275 - E283
  • [34] Residual TPO Content of Photopolymerized Additively Manufactured Dental Occlusal Splint Materials
    Messer-Hannemann, Philipp
    Wienhold, Max
    Esbak, Hoda
    Brunner, Alexander
    Schoenebaum, Andreas
    Schwendicke, Falk
    Effenberger, Susanne
    BIOMEDICINES, 2025, 13 (01)
  • [35] Characterization of occlusal splint materials: CAD-CAM versus conventional resins
    Gibreel, Mona
    Perea-Lowery, Leila
    Vallittu, Pekka K.
    Lassila, Lippo
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2021, 124
  • [36] Wear and Hardness of Different Core Build-Up Materials
    Schmage, Petra
    Nergiz, Ibrahim
    Sito, Fekry
    Platzer, Ursula
    Rosentritt, Martin
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2009, 91B (01) : 71 - 79
  • [37] In vitro wear characteristics of a nano-hydroxyapatite filled dental resin composite under two-body wear condition
    Yadav, Sukriti
    Gangwar, Swati
    JOURNAL OF MATERIALS SCIENCE, 2020, 55 (23) : 10202 - 10220
  • [38] Two-Body Wear of CoCr Fabricated by Selective Laser Melting Compared with Different Dental Alloys
    Schwindling, Franz Sebastian
    Seubert, Maren
    Rues, Stefan
    Koke, Ulrich
    Schmitter, Marc
    Stober, Thomas
    TRIBOLOGY LETTERS, 2015, 60 (02)
  • [39] A study of the flexural strength and surface hardness of different materials and technologies for occlusal device fabrication
    Prpic, Vladimir
    Slacanin, Ivan
    Schauperl, Zdravko
    Catic, Amir
    Dulcic, Niksa
    Cimic, Samir
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (06) : 955 - 959
  • [40] Two-body wear of monolithic, veneered and glazed zirconia and their corresponding enamel antagonists
    Stawarczyk, Bogna
    Oezcan, Mutlu
    Schmutz, Felix
    Trottmann, Albert
    Roos, Malgorzata
    Haemmerle, Christoph H. F.
    ACTA ODONTOLOGICA SCANDINAVICA, 2013, 71 (01) : 102 - 112