Insulation Characteristics of 1100 kV GIS under Very Fast Transient Overvoltage and Lightning Impulse

被引:22
|
作者
Zhang, Lu [1 ,2 ]
Zhang, Qiaogen [1 ,2 ]
Liu, Shi [1 ,2 ]
Liu, Fenglian [1 ,2 ]
Li, Long [1 ,2 ]
Yin, Yu [3 ]
Shi, Weidong [3 ]
Chen, Weijiang [4 ]
机构
[1] Xi An Jiao Tong Univ, Sch Elect Engn, Xian 710049, Peoples R China
[2] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Peoples R China
[3] China Elect Power Res Inst, Beijing 100192, Peoples R China
[4] State Grid Corp China, Beijing 100031, Peoples R China
关键词
GIS; VFTO; lightning impulse; breakdown voltage; space charge; BREAKDOWN CHARACTERISTICS; WAVE-FORMS; SF6; GAS; SWITCHGEARS; PROTRUSION; STREAMER; VOLTAGE; FIELD; TIME;
D O I
10.1109/TDEI.2012.6215109
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Very fast transient overvoltage (VFTO) in gas insulated switchgear (GIS) is of great concern at the higher rated voltages because the difference between the rated lightning impulse (LI) and the VFTO withstand voltage decreases. In order to clarify VFTO withstand level of 1100 kV GIS, a simulation system was designed for generation of VFTO. The breakdown characteristics of sphere-plane gap and rod-plane gap in SF6 under VFTO and LI were investigated for different gas pressures. Experimental results show that the breakdown voltages in slightly inhomogeneous field gaps under VFTO are higher than that under LI. However, for the rod-plane gaps, the breakdown voltages and voltage-time curves under VFTO fall below that of LI at higher pressure in the case of negative polarity. The polarity effect of rod-plane gaps under LI is reversed at a certain pressure. Based on the analyses, it is concluded that the different breakdown characteristics of SF6 gaps may be attribute to the difference between space charge behaviors during the discharge development under the impulse with different wave front and oscillation tail of VFTO and LI.
引用
收藏
页码:1029 / 1036
页数:8
相关论文
共 50 条
  • [11] Simulation and Test Study on Very Fast Transient Overvoltage in 1000kV GIS Substation
    Han, Bin
    Lin, Jiming
    Ban, Liangeng
    Wang, Hao
    Li, Zhibing
    Xiang, Zutao
    2017 2ND ASIA CONFERENCE ON POWER AND ELECTRICAL ENGINEERING (ACPEE 2017), 2017, 199
  • [12] Research on Very Fast Transient Overvoltage During Switching of Disconnector in 550kV GIS
    Zhao, Lin
    Ye, Liya
    Wang, Shaoan
    Yang, Yong
    Jiang, Peng
    Zou, Xiaofeng
    2018 3RD IEEE INTERNATIONAL CONFERENCE ON INTEGRATED CIRCUITS AND MICROSYSTEMS (ICICM), 2018, : 114 - 118
  • [13] Experimental Research on Very-Fast Transient Overvoltage in 1100-kV Gas-Insulated Switchgear
    Shu, Yinbiao
    Chen, Weijiang
    Li, Zhibing
    Dai, Min
    Li, Chengrong
    Liu, Weidong
    Yan, Xianglian
    IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (01) : 458 - 466
  • [14] Research on Voltage Distributions Characteristics in 800 kV GIS Under Oscillating Lightning Impulse
    Kang, Jun
    Qu, Quanlei
    Xie, Pengsheng
    He, Cong
    Li, Junhao
    Hu, Mengchen
    Li, Yuan
    Chen, Wenqiang
    2018 12TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS (ICPADM 2018), 2018, : 558 - 561
  • [15] Frequency characteristics of very fast transient currents in a 245-kV GIS
    Rao, AM
    Thomas, MJ
    Singh, BP
    IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (04) : 2450 - 2457
  • [16] Research on transient insulation numerical analysis method of circuit breaker in GIS under lightning impulse voltage
    Wu Qi
    Liu Xiaoming
    Yang Tian
    Li Longnv
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 3320 - 3324
  • [17] Overvoltage and insulation coordination for ±1100 kV UHVDC converter station
    Zhou, H. (zhouhao_ee@zju.edu.cn), 2013, Science Press (39):
  • [18] Accumulative Insulation Characteristics of 110kV GIS Spacer Under Repeated Impulse Voltages
    Wang, Zengbin
    Lv, Hong
    Wang, Liuhuo
    Chen, Yilong
    Tang, Ying
    Rao, Zhangquan
    Wu, Ji
    Liu, Shupin
    Zhou, Hongyang
    Ma, Guoming
    Zheng, Shusheng
    Li, Chengrong
    2017 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENON (CEIDP), 2017, : 185 - 188
  • [19] Insulation characteristics of GIS under nonstandard lightning impulse oscillations: Insulation characteristics under double-frequency oscillations with various frequencies and damping ratios
    Yuasa, S
    Kato, K
    Okabe, S
    ELECTRICAL ENGINEERING IN JAPAN, 2004, 146 (02) : 11 - 19
  • [20] Voltage Distribution of 220 kV GIS under Different Lightning Impulse
    Wang Si si
    Xiong Jun
    Li Zhi ning
    Jin Yuhui
    Che Bin
    Zhang Liang
    Wu Bang
    Li Jun-hao
    2016 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2016, : 558 - 561