Prognostic importance of defibrillator shocks in patients with heart failure

被引:1094
|
作者
Poole, Jeanne E. [1 ]
Johnson, George W. [2 ]
Hellkamp, Anne S. [3 ]
Anderson, Jill [2 ]
Callans, David J. [4 ]
Raitt, Merritt H. [5 ,6 ]
Reddy, Ramakota K. [7 ]
Marchlinski, Francis E. [4 ]
Yee, Raymond [8 ]
Guarnieri, Thomas [9 ]
Talajic, Mario [10 ]
Wilber, David J. [11 ]
Fishbein, Daniel P. [1 ]
Packer, Douglas L. [12 ]
Mark, Daniel B. [3 ]
Lee, Kerry L. [3 ]
Bardy, Gust H. [1 ,2 ]
机构
[1] Univ Washington, Sch Med, Div Cardiol, Seattle, WA 98195 USA
[2] Seattle Inst Cardiac Res, Seattle, WA USA
[3] Duke Clin Res Inst, Durham, NC USA
[4] Univ Penn, Philadelphia, PA 19104 USA
[5] Portland VA Med Ctr, Portland, OR USA
[6] Oregon Hlth & Sci Univ, Portland, OR 97201 USA
[7] Oregon Cardiol Assoc, Eugene, OR USA
[8] Univ Western Ontario, Univ Hosp, London, ON N6A 5A5, Canada
[9] Johns Hopkins Univ, Baltimore, MD USA
[10] Univ Montreal, Inst Cardiol Montreal, Montreal, PQ, Canada
[11] Loyola Univ, Med Ctr, Maywood, IL 60153 USA
[12] Mayo Clin, Rochester, MN USA
来源
NEW ENGLAND JOURNAL OF MEDICINE | 2008年 / 359卷 / 10期
关键词
D O I
10.1056/NEJMoa071098
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Patients with heart failure who receive an implantable cardioverter-defibrillator (ICD) for primary prevention (i.e., prevention of a first life-threatening arrhythmic event) may later receive therapeutic shocks from the ICD. Information about long-term prognosis after ICD therapy in such patients is limited. Methods: Of 829 patients with heart failure who were randomly assigned to ICD therapy, we implanted the ICD in 811. ICD shocks that followed the onset of ventricular tachycardia or ventricular fibrillation were considered to be appropriate. All other ICD shocks were considered to be inappropriate. Results: Over a median follow-up period of 45.5 months, 269 patients (33.2%) received at least one ICD shock, with 128 patients receiving only appropriate shocks, 87 receiving only inappropriate shocks, and 54 receiving both types of shock. In a Cox proportional-hazards model adjusted for baseline prognostic factors, an appropriate ICD shock, as compared with no appropriate shock, was associated with a significant increase in the subsequent risk of death from all causes (hazard ratio, 5.68; 95% confidence interval [CI], 3.97 to 8.12; P<0.001). An inappropriate ICD shock, as compared with no inappropriate shock, was also associated with a significant increase in the risk of death (hazard ratio, 1.98; 95% CI, 1.29 to 3.05; P=0.002). For patients who survived longer than 24 hours after an appropriate ICD shock, the risk of death remained elevated (hazard ratio, 2.99; 95% CI, 2.04 to 4.37; P<0.001). The most common cause of death among patients who received any ICD shock was progressive heart failure. Conclusions: Among patients with heart failure in whom an ICD is implanted for primary prevention, those who receive shocks for any arrhythmia have a substantially higher risk of death than similar patients who do not receive such shocks.
引用
收藏
页码:1009 / 1017
页数:9
相关论文
共 50 条
  • [21] A multicenter study of heart failure as a predictor for internal cardioverter defibrillator shocks
    Whang, W
    Mittleman, MA
    Wang, PJ
    Merlan, JC
    Rich, D
    Muller, JE
    Ruskin, JN
    Albert, CM
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 95A - 96A
  • [22] Relation of advanced heart failure symptoms to risk of inappropriate defibrillator shocks
    Hreybe, H
    Ezzeddine, R
    Barrington, W
    Bazaz, R
    Jain, S
    Ngwu, O
    Saba, S
    AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (04): : 544 - 546
  • [23] The prognostic importance of subclinical heart failure in stable coronary heart disease patients
    Konig, Petr
    Mayer, Otto
    Bruthans, Jan
    Seidlerova, Jitka
    Materankova, Marketa
    Gelzinsky, Julius
    Rychecka, Martina
    Karnosova, Petra
    Wohlfahrt, Peter
    Cifkova, Renata
    Filipovsky, Jan
    ACTA CARDIOLOGICA, 2020, 75 (04) : 329 - 336
  • [24] The extent of late gadolinium enhancement predicts defibrillator shocks in patients with non-ischaemic heart failure
    Aimo, A.
    Barison, A.
    Mirizzi, G.
    Castiglione, V.
    Ripoli, A.
    Panchetti, L.
    Rossi, A.
    Startari, U.
    Emdin, M.
    Aquaro, G. D.
    Piacenti, M.
    EUROPEAN HEART JOURNAL, 2019, 40 : 590 - 590
  • [25] Prevalence and prognostic impact of comorbidities in heart failure patients with implantable cardioverter-defibrillator
    Bruch, Christian
    Bruch, Chahrebanu
    Sindermann, Juergen
    Breithardt, Guenter
    Gradaus, Rainer
    EUROPACE, 2007, 9 (08): : 681 - 686
  • [26] Prognostic Significance of Hyperkalemia in Chronic Heart Failure Patients With Implantable Cardioverter-Defibrillator
    Kishihara, Makoto
    Hattori, Hidetoshi
    Suzuki, Atsushi
    Kikuchi, Noriko
    Minami, Yuichiro
    Shoda, Morio
    Hagiwara, Nobuhisa
    CIRCULATION, 2021, 144
  • [27] Association between Neutrophil/lymphocyte ratio and suitable shocks in heart failure patients with implantable cardiac defibrillator
    Yucel, H.
    Beton, O.
    Zorlu, A.
    Dogdu, O.
    Turgut, O. O.
    Yilmaz, M. B.
    EUROPEAN JOURNAL OF HEART FAILURE, 2014, 16 : 55 - 55
  • [28] RISK FACTORS FOR APPROPRIATE CARDIOVERTER-DEFIBRILLATOR SHOCKS, INAPPROPRIATE CARDIOVERTER-DEFIBRILLATOR SHOCKS, AND MORTALITY IN 549 PATIENTS WITH HEART FAILURE AND IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS
    Aronow, Wilbert S.
    Desai, Harit
    Gandhi, Kaushang
    Ahn, Chul
    Hussain, Sadaf
    Lai, Hoang M.
    Sharma, Mala
    Frishman, William H.
    Cohen, Martin
    Sorbera, Carmine
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [29] Prognostic importance of weight loss in patients with heart failure and different pre heart failure body mass
    Rozentryt, P.
    Nowak, J. U.
    Von Heahling, S.
    Sikora, J.
    John, A.
    Wilczek, U.
    Polonski, L.
    Anker, S. D.
    CIRCULATION, 2008, 118 (12) : E324 - E324
  • [30] Prognostic importance of emotional support for elderly patients hospitalized with heart failure
    Krumholz, HM
    Butler, J
    Miller, J
    Vaccarino, V
    Williams, CS
    de Leon, CFM
    Seeman, TE
    Kasl, SV
    Berkman, LF
    CIRCULATION, 1998, 97 (10) : 958 - 964