Correlating Optical Bench Performance With Clinical Defocus Curves in Varifocal and Trifocal Intraocular Lenses

被引:33
作者
Plaza-Puche, Ana B. [1 ]
Alio, Jorge L. [1 ,2 ]
MacRae, Scott [3 ,4 ]
Zheleznyak, Len [3 ,4 ]
Sala, Esperanza [1 ]
Yoon, Geunyoung [3 ,4 ]
机构
[1] Vissum Corp, Alicante, Spain
[2] Univ Miguel Hernandez, Div Ophthalmol, Alicante, Spain
[3] Univ Rochester, Flaum Eye Inst, Rochester, NY USA
[4] Univ Rochester, Inst Opt, Rochester, NY USA
关键词
VISUAL OUTCOMES; BILATERAL IMPLANTATION; IMAGE QUALITY; FOCUS; PRESBYOPIA; DESIGN; ABERRATIONS; SENTENCES; DISTANCE; RESTOR;
D O I
10.3928/1081597X-20150423-03
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To investigate the correlations existing between a trifocal intraocular lens (IOL) and a varifocal IOL using the "ex vivo" optical bench through-focus image quality analysis and the clinical visual performance in real patients by study of the defocus curves. METHODS: This prospective, consecutive, nonrandomized, comparative study included a total of 64 eyes of 42 patients. Three groups of eyes were differentiated according to the IOL implanted: 22 eyes implanted with the varifocal Lentis Mplus LS-313 IOL (Oculentis GmbH, Berlin, Germany); 22 eyes implanted with the trifocal FineVision IOL (Physiol, Liege, Belgium), and 20 eyes implanted with the monofocal Acrysof SA60AT IOL (Alcon Laboratories, Inc., Fort Worth, TX). Visual outcomes and defocus curve were evaluated postoperatively. Optical bench through-focus performance was quantified by computing an image quality metric and the cross-correlation coefficient between an unaberrated reference image and captured retinal images from a model eye with a 3.0-mm artificial pupil. RESULTS: Statistically significant differences among defocus curves of different IOLs were detected for the levels of defocus from -4.00 to -1.00 diopters (D) (P < .01). Significant correlations were found between the optical bench image quality metric results and logMAR visual acuity scale in all groups (Lentis Mplus group: r = -0.97, P < .01; FineVision group: r = -0.82, P < .01; Acrysof group: r = -0.99, P < .01). Linear predicting models were obtained. CONCLUSIONS: Significant correlations were found between logMAR visual acuity and image quality metric for the multifocal and monofocal IOLs analyzed. This finding enables surgeons to predict visual outcomes from the optical bench analysis.
引用
收藏
页码:300 / +
页数:9
相关论文
共 35 条
[1]   Visual function comparison of 2 aspheric multifocal intraocular lenses [J].
Alfonso, Jose F. ;
Fernandez-Vega, Luis ;
Blazquez, Jose I. ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (02) :242-248
[2]   Clinical outcomes and intraocular optical quality of a diffractive multifocal intraocular lens with asymmetrical light distribution [J].
Alio, Jorge L. ;
Elkady, Bassarn ;
Ortiz, Dolores ;
Bernabeu, Gonzalo .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (06) :942-948
[3]   Design of short Spanish sentences for measuring reading performance:: Radner-Vissum test [J].
Alio, Jorge L. ;
Radner, Wolfgang ;
Plaza-Puche, Ana B. ;
Ortiz, Dolores ;
Carmen Neipp, M. ;
Jose Quiles, M. ;
Rodriguez-Marin, Jesus .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (04) :638-642
[4]   Visual Outcomes of a Trifocal Aspheric Diffractive Intraocular Lens With Microincision Cataract Surgery [J].
Alio, Jorge L. ;
Montalban, Raul ;
Pena-Garcia, Pablo ;
Soria, Felipe A. ;
Vega-Estrada, Alfredo .
JOURNAL OF REFRACTIVE SURGERY, 2013, 29 (11) :756-761
[5]   Clinical and Optical Intraocular Performance of Rotationally Asymmetric Multifocal IOL Plate-Haptic Design Versus C-Loop Haptic Design [J].
Alio, Jorge L. ;
Plaza-Puche, Ana B. ;
Javaloy, Jaime ;
Jose Ayala, Maria ;
Vega-Estrada, Alfredo .
JOURNAL OF REFRACTIVE SURGERY, 2013, 29 (04) :252-259
[6]   Rotationally Asymmetric Multifocal IOL Implantation With and Without Capsular Tension Ring: Refractive and Visual Outcomes and Intraocular Optical Performance [J].
Alio, Jorge L. ;
Plaza-Puche, Ana B. ;
Pinero, David P. .
JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (04) :253-258
[7]   Comparison of a New Refractive Multifocal Intraocular Lens with an Inferior Segmental Near Add and a Diffractive Multifocal Intraocular Lens [J].
Alio, Jorge L. ;
Plaza-Puche, Ana B. ;
Javaloy, Jaime ;
Jose Ayala, Maria ;
Moreno, Luis J. ;
Pinero, David P. .
OPHTHALMOLOGY, 2012, 119 (03) :555-563
[8]   Visual outcomes and optical performance of a monofocal intraocular lens and a new-generation multifocal intraocular lens [J].
Alio, Jorge L. ;
Pinero, David P. ;
Plaza-Puche, Ana B. ;
Joanna Rodriguez, Maria .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (02) :241-250
[9]   Evidence for delayed presbyopia after photorefractive keratectomy for myopia [J].
Artola, A ;
Patel, S ;
Schimchak, P ;
Ayala, MJ ;
Ruiz-Moreno, JM ;
Alió, JL .
OPHTHALMOLOGY, 2006, 113 (05) :735-741
[10]   Evaluation of image quality after implantation of 2 diffractive multifocal intraocular lens models [J].
Castillo-Gomez, Alfredo ;
Carmona-Gonzalez, David ;
Maria Martinez-de-la-Casa, Jose ;
Palomino-Bautista, Carlos ;
Garcia-Feijoo, Julian .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (07) :1244-1250