Non isocentric film-based intracavitary brachytherapy planning in cervical cancer: a retrospective dosimetric analysis with CT planning

被引:9
作者
Tyagi, Kirti [1 ]
Mukundan, Hari [1 ]
Mukherjee, Deboleena [1 ]
Semwal, Manoj [2 ]
Sarin, Arti [2 ]
机构
[1] INHS Asvini, Radiat Oncol Ctr, Bombay 400005, Maharashtra, India
[2] R&R Hosp, Dept Radiotherapy, Delhi, India
关键词
bladder dose; brachytherapy; cervical cancer; radiograph; rectal dose; DOSE-RATE BRACHYTHERAPY; CARCINOMA;
D O I
10.5114/jcb.2012.30678
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To compare intracavitary brachytherapy dose estimation for organs at risk (bladder and rectum) based on semi-orthogonal reconstruction of radiographs on non-isocentric X-ray unit and Computed Tomography (CT) - based volumetric planning in cervical cancer. Material and methods: Bladder and rectal points as per International Commission on Radiation Units and Measurements (ICRU) report 38, were retrospectively evaluated on 15 high dose rate intracavitary brachytherapy applications for cervical cancer cases. With the same source configuration as obtained during planning on radiographs performed on a non-isocentric X-ray unit, the mean doses to 2cc of most irradiated part of bladder and rectum were computed by CT planning and these estimates were compared with the doses at ICRU bladder and rectal points. Results: The mean ICRU point dose for bladder was 3.08 Gy (1.9-5.9 Gy) and mean dose to 2 cc (D2cc) bladder was 6.91 Gy (2.9-12.2 Gy). ICRU rectal dose was 3.8 Gy (2.4-4.45 Gy) and was comparable with D2cc rectum dose 4.2 Gy ( 2.8-5.9 Gy). Comparison of mean total dose (ICRU point vs. D2cc) for each patient was found to be significantly different for bladder (p = 0.000), but not for rectum (p = 0.08). Conclusions: On comparison of ICRU point based planning with volumetric planning on CT, it was found that bladder doses were underestimated by the film based method. However, the rectal doses were found to be similar to the D2cc doses. The results with non isocentric film based treatment planning were similar to the existing literature on orthogonal film based simulator planning.
引用
收藏
页码:129 / 134
页数:6
相关论文
共 50 条
  • [21] Dosimetric comparison of two different applicators and rectal retraction methods used in inverse optimization-based intracavitary brachytherapy for cervical cancer
    Biltekin, Fatih
    Gultekin, Melis
    Yilmaz, Melek Tugce
    Yildiz, Ferah
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2020, 12 (01) : 35 - 43
  • [22] CONE BEAM CT-BASED THREE-DIMENSIONAL PLANNING IN HIGH-DOSE-RATE BRACHYTHERAPY FOR CERVICAL CANCER
    Al-Halabi, Hani
    Portelance, Lorraine
    Duclos, Marie
    Reniers, Brigitte
    Bahoric, Boris
    Souhami, Luis
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 77 (04): : 1092 - 1097
  • [23] Inverse planning simulated annealing for magnetic resonance imaging-based intracavitary high-dose-rate brachytherapy for cervical cancer
    Kubicky, Charlotte Dai
    Yeh, Benjamin M.
    Lessard, Etienne
    Joe, Bonnie N.
    Speight, Joycelyn L.
    Pouliot, Jean
    Hsu, I-Chow
    BRACHYTHERAPY, 2008, 7 (03) : 242 - 247
  • [24] Correlation analysis of CT-based rectal planning dosimetric parameters with in vivo dosimetry of MOSkin and PTW 9112 detectors in Co-60 source HDR intracavitary cervix brachytherapy
    Jamalludin, Z.
    Malik, R. A.
    Ung, N. M.
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2021, 44 (03) : 773 - 783
  • [25] Direction Modulated Brachytherapy for Treatment of Cervical Cancer. II: Comparative Planning Study With Intracavitary and Intracavitary-Interstitial Techniques
    Han, Dae Yup
    Safigholi, Habib
    Soliman, Abraam
    Ravi, Ananth
    Leung, Eric
    Scanderbeg, Daniel J.
    Liu, Zhaowei
    Owrangi, Amir
    Song, William Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : 440 - 448
  • [26] Effect of bladder distension on dosimetry of organs at risk in computer tomography based planning of high-dose-rate intracavitary brachytherapy for cervical cancer
    Patra, Niladri B.
    Manir, Kazi S.
    Basu, Swapnendu
    Goswami, Jyotirup
    Kabasi, Apurba K.
    Sarkar, Shyamal K.
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2013, 5 (01) : 3 - 9
  • [27] Assessing cumulative dose distributions in combined external beam radiotherapy and intracavitary brachytherapy for cervical cancer by treatment planning based on deformable image registration
    Zeng, Jing
    Chen, Jie
    Zhang, Daguang
    Meng, Maobin
    Zhang, Bailin
    Qu, Pengpeng
    Pang, Qingsong
    Wang, Ping
    TRANSLATIONAL CANCER RESEARCH, 2020, 9 (10) : 6107 - 6115
  • [28] Clinical analysis of speculum-based vaginal packing for high-dose-rate intracavitary tandem and ovoid brachytherapy in cervical cancer
    Sud, Shivani
    Roth, Toni
    Jones, Ellen
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2018, 10 (01) : 32 - 39
  • [29] Different effects of bladder distention on point A-based and 3D-conformal intracavitary brachytherapy planning for cervical cancer
    Ju, Sang Gyu
    Huh, Seung Jae
    Shin, Jung Suk
    Park, Won
    Nam, Heerim
    Bae, Sunhyun
    Oh, Dongryul
    Hong, Chae-Seon
    Kim, Jin Sung
    Han, Youngyih
    Choi, Doo Ho
    JOURNAL OF RADIATION RESEARCH, 2013, 54 (02) : 349 - 356
  • [30] Change in image-guided planning strategies over time impacts oncologic and survival outcomes for intracavitary cervical cancer brachytherapy
    D'Cunha, Paul
    Gonzalez, Yesenia
    Nwachukwu, Chika
    Hrycushko, Brian
    Medin, Paul
    Owrangi, Amir
    Jia, Xun
    Albuquerque, Kevin
    BRACHYTHERAPY, 2022, 21 (05) : 668 - 677