Energy Selective X-Ray Imaging with Medipix

被引:0
作者
Procz, S. [1 ]
Luebke, J. [2 ]
Zwerger, A. [1 ]
Fauler, A. [1 ]
Pichotka, M. [1 ]
Mix, M. [2 ]
Fiederle, M. [1 ]
机构
[1] Freiburger Mat Forschungszentrum FMF, Stefan Meier Str 21, D-79104 Freiburg, Germany
[2] Univ Freiburg, D-79104 Freiberg, Germany
来源
2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC) | 2010年
关键词
PIXEL READOUT CHIP; SINGLE; WORKING; SYSTEM;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Pixelated photon counting semiconductor X-ray detectors like the Medipix feature adjustable energy thresholds allowing selective counting of photons of a specified energy. This enables energy selective X-ray imaging with advanced material information. Furthermore the photon counting function principle of these detectors enables almost noiseless X-ray imaging providing a high contrast in low contrast objects. The aim of this study is to analyze the stability of the new Medipix3 detector especially in relation to flatfield correction for X-ray imaging applications and to present its use for high resolution low contrast X-ray imaging, and for energy selective X-ray imaging as well.
引用
收藏
页码:3846 / 3851
页数:6
相关论文
共 10 条
  • [1] The medipix3 prototype, a pixel readout chip working in single photon counting mode with improved spectrometric performance
    Ballabriga, R.
    Campbell, M.
    Heijne, E. H. M.
    Llopart, X.
    Tlustos, L.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (05) : 1824 - 1829
  • [2] Bio-medical X-ray imaging with spectroscopic pixel detectors
    Butler, A. P. H.
    Anderson, N. G.
    Tipples, R.
    Cook, N.
    Watts, R.
    Meyer, J.
    Bell, A. J.
    Melzer, T. R.
    Butler, P. H.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 591 (01) : 141 - 146
  • [3] The influence of energy weighting on X-ray imaging quality
    Giersch, J
    Niederlöhner, D
    Anton, G
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 531 (1-2) : 68 - 74
  • [4] Medipix2:: a 64-k pixel readout chip with 55 μm square elements working in single photon counting mode
    Llopart, X
    Campbell, M
    Dinapoli, R
    Segundo, DS
    Pemigotti, E
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) : 2279 - 2283
  • [5] X-ray energy selected imaging with Medipix II
    Ludwig, J
    Zwerger, A
    Benz, KW
    Fiederle, M
    Braml, H
    Fauler, A
    Konrath, JP
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 531 (1-2) : 209 - 214
  • [6] Characterisation of a single photon counting pixel system for imaging of low-contrast objects
    Mikulec, B
    Campbell, M
    Dipasquale, G
    Schwarz, C
    Watt, J
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2) : 352 - 359
  • [7] Optimization of Medipix-2 Threshold Masks for Spectroscopic X-Ray Imaging
    Procz, Simon
    Luebke, Joerdis
    Zwerger, Andreas
    Mix, Michael
    Fiederle, Michael
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (04) : 1795 - 1799
  • [8] Imaging properties of the Medipix2 system exploiting single and dual energy thresholds
    Tlustos, L
    Ballabriga, R
    Campbell, M
    Heijne, E
    Kincade, K
    Llopart, X
    Stejskal, P
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) : 367 - 372
  • [9] Signal variations in high-granularity Si pixel detectors
    Tlustos, L
    Campbell, M
    Heijne, E
    Llopart, X
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (06) : 3006 - 3012
  • [10] Dose reductions in dental X-ray imaging using Medipix
    Watt, J
    Davidson, DW
    Johnston, C
    Smith, C
    Tlustos, L
    Mikulec, B
    Smith, KM
    Rahman, M
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 513 (1-2) : 65 - 69