Optinuzing design of over voltage protector for HV power cable metallic shield grounding

被引:0
作者
Luo, Junhua [1 ]
Zhou, Zuochun [2 ]
Luo, Min [3 ]
机构
[1] Wuhan High Voltage Res Inst, Wuhan 430074, Hubei, Peoples R China
[2] Beijing Elect Power Corp, Beijing PT-100031, Peoples R China
[3] Huazhong Univ Sci & Technol, Wuhan PT-430074, Peoples R China
来源
2008 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3 | 2008年
关键词
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Operation faults of HV power cable lines have been increasing because of multi-points grounding of cable sheath which caused by over voltage breakdown. Cable metallic shield grounding and over voltage protecting techniques have been noticeably along with more and more underground power cable lines applied in urban transmission and distribution system. It is the key for us to design and optimize the technical parameters of over voltage protector used for single-core power cable metallic shield grounding and over voltage protecting. But neither international nor national standards have defined the rules of how to choose the parameters until today. In this paper, the rules and methods of design and optimization of over voltage protector for cable metallic shield grounding and over voltage protecting were discussed based on national standards of China such as GB 50217 Code for Design of Cables of Electric Work, DL/T401 Guide to the Selection of High Voltage Cables and DL/T5221 Technical Rule for Design of Urban Power Cables as well as practical experience of long-term operation of power cable lines. Furthermore, lightning impulse test and large impulse current test were used for validating reliability and preponderance of the protector design in the paper. The results of theory analysis and tests proved that the over voltage protector for cable metallic shield grounding and over voltage protecting designed by the rules can satisfy the technical requirements of the standards and meet the practical demands of power cable lines operating safely and reliably.
引用
收藏
页码:1542 / +
页数:2
相关论文
共 10 条
[1]   Adaptive improving forward-link soft handoff performance in power-controlled DS-CDMA cellular networks [J].
Chen, Wen ;
Lei, Feiyu ;
Wang, Weinong .
COMPUTERS & ELECTRICAL ENGINEERING, 2006, 32 (1-3) :37-49
[2]  
DONG ZG, 1997, VOLTAGE ELECT POWER
[3]  
GUO XL, 2003, J ELECT POWER, V18
[4]  
JIANG RO, 1997, XLPE POWER CABLE LIN
[5]  
[李锦鹏 Li Jinpeng], 2004, [高电压技术, High Voltage Engineering], V30, P28
[6]  
LUO JH, 2000, HIGH VOLTAGE ENG, V26, P68
[7]  
Niu Haiqing, 2005, High Voltage Engineering, V31, P15
[8]  
PING C, 2004, HIGH VOLTAGE ENG, V30, P6
[9]  
XU Y, 2003, LIGHTNING PROTECTION, P4
[10]  
Zhang Quansheng, 2005, High Voltage Engineering, V31, P71