Influence of the amino acid sequence and nature of the cyclodextrin on the separation of small peptide enantiomers by capillary electrophoresis using α-, β-, and γ-cyclodextrin and the corresponding hydroxypropyl derivatives

被引:0
作者
Sidamonidze, N
Süss, F
Poppitz, W
Scriba, GKE
机构
[1] Univ Jena, Sch Pharm, Dept Pharmaceut Chem, D-07743 Jena, Germany
[2] Univ Jena, Dept Inorgan & Analyt Chem, D-07743 Jena, Germany
关键词
chiral separation; peptides; cyclodextrins; capillary electrophoresis; electrospray ionization mass spectrometry;
D O I
10.1002/1615-9314(20010901)24:9<777::AID-JSSC777>3.0.CO;2-V
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The separation of the LL and DD enantiomers of dipeptides and tripeptides using alpha-, beta-, and gamma -cyclodextrins as well as the corresponding hydroxypropyl derivatives was studied with respect to the amino acid sequence of the peptides and the nature of the cyclodextrins Standardized conditions regarding buffer pH and molarity, cyclodextrin concentration, and separation voltage were applied. a-Cyclodextrin, hydroxypropyl-alpha -cyclodextrin, P-cyclodextrin, and hydroxypropyl-p-cyclodextrin were the more universal cyclodextrins for enantioseparations of the investigated set of peptides compared to gamma -cyclodextrin and hydroxypropyl-gamma -cyclodextrin. The enantiomer migration order depended both on the cyclodextrin and on the amino acid sequence of the peptide. Reversal of the enantiomer migration order upon increasing the buffer pH from 2.5 to 3.5 was observed in some cases using beta -cyclodextrin.
引用
收藏
页码:777 / 783
页数:7
相关论文
共 40 条
[1]  
Bodanszky M., 1994, PRACTICE PEPTIDE SYN, P110, DOI 10.1007/978-3-642-85055-4.
[2]  
Chankvetadze B, 2000, ENANTIOMER, V5, P313
[3]   Determination of enantiomers in a synthetic argininal peptide using capillary zone electrophoresis and high-performance liquid chromatography [J].
Dan, N ;
Ganesan, R ;
Flood, KG ;
Tsai, D ;
Reif, VD .
JOURNAL OF CHROMATOGRAPHY A, 2000, 891 (01) :115-127
[4]   CHIRAL SEPARATION OF NAPHTHALENE-2,3-DIALDEHYDE LABELED PEPTIDES BY CYCLODEXTRIN-MODIFIED ELECTROKINETIC CHROMATOGRAPHY [J].
DESILVA, K ;
JIANG, Q ;
KUWANA, T .
BIOMEDICAL CHROMATOGRAPHY, 1995, 9 (06) :295-301
[5]   Electrokinetic chromatography in suppressed electroosmotic flow environment: Use of a charged cyclodextrin for the separation of enantiomers and geometric isomers [J].
Janini, GM ;
Muschik, GM ;
Issaq, HJ .
ELECTROPHORESIS, 1996, 17 (10) :1575-1583
[6]  
Kasicka V, 1999, ELECTROPHORESIS, V20, P3084, DOI 10.1002/(SICI)1522-2683(19991001)20:15/16<3084::AID-ELPS3084>3.0.CO
[7]  
2-4
[8]   EVALUATION OF AN OPTICALLY-ACTIVE CROWN-ETHER FOR THE CHIRAL SEPARATION OF DIPEPTIDES AND TRIPEPTIDES [J].
KUHN, R ;
RIESTER, D ;
FLECKENSTEIN, B ;
WIESMULLER, KH .
JOURNAL OF CHROMATOGRAPHY A, 1995, 716 (1-2) :371-379
[9]  
Li JJ, 1999, ELECTROPHORESIS, V20, P171, DOI 10.1002/(SICI)1522-2683(19990101)20:1<171::AID-ELPS171>3.3.CO
[10]  
2-Y