Estimation of the two-dimensional presampled modulation transfer function of digital radiography devices using one-dimensional test objects

被引:5
作者
Wells, Jered R. [1 ,2 ]
Dobbins, James T., III [1 ,2 ,3 ,4 ,5 ]
机构
[1] Duke Univ, Med Ctr, Carl E Ravin Adv Imaging Labs, Durham, NC 27705 USA
[2] Duke Univ, Med Phys Grad Program, Durham, NC 27705 USA
[3] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27705 USA
[4] Duke Univ, Dept Biomed Engn, Durham, NC 27705 USA
[5] Duke Univ, Dept Phys, Durham, NC 27705 USA
基金
美国国家卫生研究院;
关键词
modulation transfer function (MTF); digital radiography; resolution; edge spread function; line spread function; DETECTIVE QUANTUM EFFICIENCY; IMAGE QUALITY CHARACTERIZATION; ACQUISITION DEVICES; SPREAD FUNCTION; SYSTEMS; MTF; NOISE; PERFORMANCE; LINE;
D O I
10.1118/1.4752442
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The modulation transfer function (MTF) of medical imaging devices is commonly reported in the form of orthogonal one-dimensional (1D) measurements made near the vertical and horizontal axes with a slit or edge test device. A more complete description is found by measuring the two-dimensional (2D) MTF. Some 2D test devices have been proposed, but there are some issues associated with their use: (1) they are not generally available; (2) they may require many images; (3) the results may have diminished accuracy; and (4) their implementation may be particularly cumbersome. This current work proposes the application of commonly available 1D test devices for practical and accurate estimation of the 2D presampled MTF of digital imaging systems. Methods: Theory was developed and applied to ensure adequate fine sampling of the system line spread function for 1D test devices at orientations other than approximately vertical and horizontal. Methods were also derived and tested for slit nonuniformity correction at arbitrary angle. Techniques were validated with experimental measurements at ten angles using an edge test object and three angles using a slit test device on an indirect-detection flat-panel system [GE Revolution XQ/i (GE Healthcare, Waukesha, WI)]. The 2D MTF was estimated through a simple surface fit with interpolation based on Delaunay triangulation of the ID edge-based MTF measurements. Validation by synthesis was also performed with simulated images from a hypothetical direct-detection flat-panel device. Results: The 2D MTF derived from physical measurements yielded an average relative precision error of 0.26% for frequencies below the cutoff (2.5 mm(-1)) and approximate circular symmetry at frequencies below 4 mm(-1). While slit analysis generally agreed with the results of edge analysis, the two showed subtle differences at frequencies above 4 mm(-1). Slit measurement near 45 degrees revealed radial asymmetry in the MTF resulting from the square pixel aperture (0.2 mm x 0.2 mm), a characteristic which was not necessarily appreciated with the orthogonal 1D MTF measurements. In simulation experiments, both slit- and edge-based measurements resolved the radial asymmetries in the 2D MTF. The average absolute relative accuracy error in the 2D MTF between the DC and cutoff (2.5 mm(-1)) frequencies was 0.13% with average relative precision error of 0.11%. Other simulation results were similar to those derived from physical data. Conclusions: Overall, the general availability, acceptance, accuracy, and ease of implementation of ID test devices for MTF assessment make this a valuable technique for 2D MTF estimation. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4752442]
引用
收藏
页码:6148 / 6160
页数:13
相关论文
共 50 条
  • [1] Measurement of the presampled two-dimensional modulation transfer function of digital imaging systems
    Fetterly, KA
    Hangiandreou, NJ
    Schueler, BA
    Ritenour, ER
    MEDICAL PHYSICS, 2002, 29 (05) : 913 - 921
  • [2] Method for determining the two-dimensional presampling modulation transfer function in digital radiography
    Båth, M
    Sund, P
    Månsson, LG
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 268 - 279
  • [3] Two-dimensional modulation transfer function: a new perspective
    Marom, Emanuel
    Milgrom, Benjamin
    Konforti, Naim
    APPLIED OPTICS, 2010, 49 (35) : 6749 - 6755
  • [4] Use of Wiener filtering in the measurement of the two-dimensional modulation transfer function
    Reimann, DA
    Jacobs, HA
    Samei, E
    MEDICAL IMAGING 2000: PHYSICS OF MEDICAL IMAGING, 2000, 3977 : 670 - 680
  • [5] A method for the determination of the two-dimensional MTF of digital radiography systems using only the noise response
    Kuhls-Gilcrist, Andrew
    Bednarek, Daniel R.
    Rudin, Stephen
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [6] Analysis of One-Dimensional Inviscid and Two-Dimensional Viscous Flows Using Entropy Preserving Method
    Javadi, Ali
    Pasandideh-Fard, Mahmoud
    Malek-Jafarian, Majid
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2014, 39 (10) : 7315 - 7325
  • [8] Likelihood of total resolution in liquid chromatography: Evaluation of one-dimensional, comprehensive two-dimensional, and selective comprehensive two-dimensional liquid chromatography
    Davis, Joe M.
    Stoll, Dwight R.
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1360 : 128 - 142
  • [9] New types of one-dimensional discrete breathers in a two-dimensional lattice
    Semenov, A. S.
    Murzaev, R. T.
    Bebikhov, Yu, V
    Kudreyko, A. A.
    Dmitriev, S., V
    LETTERS ON MATERIALS, 2020, 10 (02): : 185 - 188
  • [10] Two-dimensional materials and one-dimensional carbon nanotube composites for microwave absorption
    Mu, Congpu
    Song, Jiefang
    Wang, Bochong
    Zhang, Can
    Xiang, Jianyong
    Wen, Fusheng
    Liu, Zhongyuan
    NANOTECHNOLOGY, 2018, 29 (02)