ZnO/porous carbon composite from a mixed-ligand MOF for ultrasensitive electrochemical immunosensing of C-reactive protein

被引:76
作者
Dong, Sheying [1 ]
Zhang, Dandan [1 ]
Cui, Hao [2 ]
Huang, Tinglin [2 ]
机构
[1] Xian Univ Architecture & Technol, Sch Chem & Chem Engn, Xian 710055, Shaanxi, Peoples R China
[2] Xian Univ Architecture & Technol, Sch Environm & Municipal Engn, Xian 710055, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Pyrolysis; ZnO/MPC; Lable-free; Electrochemical immunosensor; C-reactive protein; LABEL-FREE DETECTION; HIGH-PERFORMANCE; GRAPHENE OXIDE; ZNO COMPOSITES; POROUS CARBON; BIOSENSOR; GOLD; GLUCOSE; NANOSTRUCTURES; NANOCOMPOSITE;
D O I
10.1016/j.snb.2018.12.150
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Carbon-based nano-composite materials obtained via simple thermolysis of metal-organic framework (MOF) have competitive virtues in accordance of layered porosity, controllable morphologies, and easily functionalizing with other metal/metallic oxides or hetero atoms. These make them directly as high activity catalysts or supports for various electrochemical sensor. Herein, we developed a novel ZnO/porous carbon matrix (ZnO/MPC)-based electrochemical immunosensing through thermolysis of a mixed-ligand MOF (Zn-BDC-TED) for real sample analysis of C-reactive protein. The ZnO/MPC and ionic liquid (IL) composite membrane modified electrode displayed prominent conductivity and biocompatibility for ultrasensitive detection of C-reactive protein (CRP). Subsequently, the step-by-step assembly process of the CRP immunosensor was monitored by electrochemical measurements including cyclic voltammogram (CV) and electrochemical impedance spectra (EIS). After the parameter optimization, the differential pulse voltammetry (DPV) response decreased linearly with the logarithm of CRP levels in an extensive range of 0.01-1000 ng.mL(-1), and the detection limit was as low as 5.0 pg.mL(-1). Meanwhile, the lable-free immunosensor also showed excellent selectivity, reproducibility and stability. We believe that ZnO/MPC composite and many carbon-based nano-composite materials obtained via simple thermolysis of MOF will be a prospective platform for sensitive detecting other biomarkers.
引用
收藏
页码:354 / 361
页数:8
相关论文
共 39 条
  • [1] A comprehensive biosensor integrated with a ZnO nanorod FET array for selective detection of glucose, cholesterol and urea
    Ahmad, Rafiq
    Tripathy, Nirmalya
    Park, Jin-Ho
    Hahn, Yoon-Bong
    [J]. CHEMICAL COMMUNICATIONS, 2015, 51 (60) : 11968 - 11971
  • [2] An optimised electrochemical biosensor for the label-free detection of C-reactive protein in blood
    Bryan, Thomas
    Luo, Xiliang
    Bueno, Paulo R.
    Davis, Jason J.
    [J]. BIOSENSORS & BIOELECTRONICS, 2013, 39 (01) : 94 - 98
  • [3] A new family of carbon materials: synthesis of MOF-derived nanoporous carbons and their promising applications
    Chaikittisilp, Watcharop
    Ariga, Katsuhiko
    Yamauchi, Yusuke
    [J]. JOURNAL OF MATERIALS CHEMISTRY A, 2013, 1 (01) : 14 - 19
  • [4] Inorganic/Organic Doped Carbon Aerogels As Biosensing Materials for the Detection of Hydrogen Peroxide
    Dong, Sheying
    Li, Nan
    Suo, Gaochao
    Huang, Tinglin
    [J]. ANALYTICAL CHEMISTRY, 2013, 85 (24) : 11739 - 11746
  • [5] Direct electrochemistry of glucose oxidase immobilized on Au nanoparticles-functionalized 3D hierarchically ZnO nanostructures and its application to bioelectrochemical glucose sensor
    Fang, Linxia
    Liu, Bing
    Liu, Lulu
    Li, Yuehua
    Huang, Kejing
    Zhang, Qiuyu
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2016, 222 : 1096 - 1102
  • [6] Dual signal amplification strategy of Au nanopaticles/ZnO nanorods hybridized reduced graphene nanosheet and multienzyme functionalized Au@ZnO composites for ultrasensitive electrochemical detection of tumor biomarker
    Fang, Xian
    Liu, Junfeng
    Wang, Jing
    Zhao, Hong
    Ren, Hongxuan
    Li, Zengxi
    [J]. BIOSENSORS & BIOELECTRONICS, 2017, 97 : 218 - 225
  • [7] Comparing label free electrochemical impedimetric and capacitive biosensing architectures
    Fernandes, Flavio C. B.
    Santos, Adriano
    Martins, Denise C.
    Goes, Marcio S.
    Bueno, Paulo R.
    [J]. BIOSENSORS & BIOELECTRONICS, 2014, 57 : 96 - 102
  • [8] An electrochemical immunosensor for ultrasensitive detection of carbohydrate antigen 199 based on Au@CuxOS yolk-shell nanostructures with porous shells as labels
    Guo, Aiping
    Li, Yueyun
    Cao, Wei
    Meng, Xianchao
    Wu, Dan
    Wei, Qin
    Du, Bin
    [J]. BIOSENSORS & BIOELECTRONICS, 2015, 63 : 39 - 46
  • [9] Label-free detection of C-reactive protein using a carbon nanofiber based biosensor
    Gupta, Rakesh K.
    Periyakaruppan, Adaikkappan
    Meyyappan, M.
    Koehne, Jessica E.
    [J]. BIOSENSORS & BIOELECTRONICS, 2014, 59 : 112 - 119
  • [10] A multi-virus detectable microfluidic electrochemical immunosensor for simultaneous detection of H1N1, H5N1, and H7N9 virus using ZnO nanorods for sensitivity enhancement
    Han, Ji-Hoon
    Lee, Dongyoung
    Chew, Charleson Hong Chuang
    Kim, Taeheon
    Pak, James Jungho
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2016, 228 : 36 - 42