Unwanted detachment of the Solitaire device during mechanical thrombectomy in acute ischemic stroke

被引:14
作者
Castano, C. [1 ]
Dorado, L. [2 ]
Remollo, S. [1 ]
Garcia-Bermejo, P. [3 ]
Gomis, M. [2 ]
de la Ossa, N. Perez [2 ]
Millan, M. [2 ]
Garcia-Sort, M. R. [1 ]
Hidalgo, C. [1 ]
Lopez-Cancio, E. [2 ]
Cubells, C. [4 ]
Davalos, A. [2 ]
机构
[1] Hosp Badalona Germans Trias & Pujol, Intervent Neuroradiol Unit, Badalona, Barcelona, Spain
[2] Hosp Badalona Germans Trias & Pujol, Acute Stroke Unit, Serv Neurol, Dept Neurosci, Badalona, Barcelona, Spain
[3] Hamad Gen Hosp, Acad Hlth Syst, Departament Neurol, Doha, Qatar
[4] Univ Autonoma Barcelona, Hosp Univ Germans Trias & Pujol, Dept Anesthesiol, Badalona, Barcelona, Spain
关键词
ENDOVASCULAR TREATMENT; AB DEVICE; STENT; RETRIEVER; EXPERIENCE; TRIAL;
D O I
10.1136/neurintsurg-2015-012156
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Background The use of retrievable stents for endovascular clot retrieval has dramatically improved successful revascularization and clinical outcome in selected patients with acute stroke. Objective To describe the rate and clinical consequences of unwanted spontaneous detachment of these devices during mechanical thrombectomy. Methods We studied 262 consecutive patients treated with the retrievable stent, Solitaire, for acute ischemic stroke between November 2008 and April 2015. Clinical, procedural, and outcome variables were compared between patients with and without unexpected detachment of this device. Detachment was classified as proximal to the stent proximal marker (type A) or distal to the marker (type B). Poor functional outcome was defined as modified Rankin scale score >2 at 90 days. Results Unwanted detachment occurred in 6/262 (2.3%) cases, four of type A and two of type B. Stent recovery was possible in three patients, all of 'type A', but in none of 'type B'. The number of prior passes was higher in patients with undesired detachment (3 (2-5) vs 2 (1-3), p=0.007). Detachment was associated with higher rate of symptomatic intracranial hemorrhage (SICH) (33.3% vs 4.3%, p=0.001), poorer outcome (100% vs 54.8%, p=0.028), and higher mortality rate at 90 days (50% vs 17%, p=0.038). Conclusions Unwanted detachment of a Solitaire is an uncommon complication during mechanical thrombectomy in patients with acute ischemic stroke and is associated with the clot retrieval attempts, SICH, poor outcome, and higher mortality.
引用
收藏
页码:1226 / +
页数:6
相关论文
共 18 条
[1]  
[Anonymous], 2008, CEREBROVASC DIS, V25, P257
[2]  
[Anonymous], 2012, TR08072 COV INT TEST
[3]  
[Anonymous], 2012, TRNV10558B COV INT T
[4]  
[Anonymous], 2009, PROT NEUR TRAT TROMB
[5]   A Randomized Trial of Intraarterial Treatment for Acute Ischemic Stroke [J].
Berkhemer, O. A. ;
Fransen, P. S. S. ;
Beumer, D. ;
van den Berg, L. A. ;
Lingsma, H. F. ;
Yoo, A. J. ;
Schonewille, W. J. ;
Vos, J. A. ;
Nederkoorn, P. J. ;
Wermer, M. J. H. ;
van Walderveen, M. A. A. ;
Staals, J. ;
Hofmeijer, J. ;
van Oostayen, J. A. ;
Nijeholt, G. J. Lycklama A. ;
Boiten, J. ;
Brouwer, P. A. ;
Emmer, B. J. ;
de Bruijn, S. F. ;
van Dijk, L. C. ;
Kappelle, L. J. ;
Lo, R. H. ;
Van Dijk, E. J. ;
de Vries, J. ;
de Kort, P. L. M. ;
van Rooij, W. J. J. ;
van den Berg, J. S. P. ;
van Hasselt, B. A. A. M. ;
Aerden, L. A. M. ;
Dallinga, R. J. ;
Visser, M. C. ;
Bot, J. C. J. ;
Vroomen, P. C. ;
Eshghi, O. ;
Schreuder, T. H. C. M. L. ;
Heijboer, R. J. J. ;
Keizer, K. ;
Tielbeek, A. V. ;
den Hertog, H. M. ;
Gerrits, D. G. ;
van den Berg-Vos, R. M. ;
Karas, G. B. ;
Steyerberg, E. W. ;
Flach, H. Z. ;
Marquering, H. A. ;
Sprengers, M. E. S. ;
Jenniskens, S. F. M. ;
Beenen, L. F. M. ;
van den Berg, R. ;
Koudstaal, P. J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2015, 372 (01) :11-20
[6]   Endovascular Therapy for Ischemic Stroke with Perfusion-Imaging Selection [J].
Campbell, B. C. V. ;
Mitchell, P. J. ;
Kleinig, T. J. ;
Dewey, H. M. ;
Churilov, L. ;
Yassi, N. ;
Yan, B. ;
Dowling, R. J. ;
Parsons, M. W. ;
Oxley, T. J. ;
Wu, T. Y. ;
Brooks, M. ;
Simpson, M. A. ;
Miteff, F. ;
Levi, C. R. ;
Krause, M. ;
Harrington, T. J. ;
Faulder, K. C. ;
Steinfort, B. S. ;
Priglinger, M. ;
Ang, T. ;
Scroop, R. ;
Barber, P. A. ;
McGuinness, B. ;
Wijeratne, T. ;
Phan, T. G. ;
Chong, W. ;
Chandra, R. V. ;
Bladin, C. F. ;
Badve, M. ;
Rice, H. ;
de Villiers, L. ;
Ma, H. ;
Desmond, P. M. ;
Donnan, G. A. ;
Davis, S. M. .
NEW ENGLAND JOURNAL OF MEDICINE, 2015, 372 (11) :1009-1018
[7]   Use of the New Solitaire™ AB Device for Mechanical Thrombectomy when Merci Clot Retriever Has Failed to Remove the Clot A Case Report [J].
Castano, C. ;
Serena, J. ;
Davalos, A. .
INTERVENTIONAL NEURORADIOLOGY, 2009, 15 (02) :209-214
[8]   Mechanical Thrombectomy With the Solitaire AB Device in Large Artery Occlusions of the Anterior Circulation A Pilot Study [J].
Castano, Carlos ;
Dorado, Laura ;
Guerrero, Cristina ;
Millan, Monica ;
Gomis, Meritxell ;
Perez de la Ossa, Natalia ;
Castellanos, Mar ;
Rosa Garcia, M. ;
Domenech, Sira ;
Davalos, Antoni .
STROKE, 2010, 41 (08) :1836-1840
[9]   Hemorrhagic Risk of Emergent Endovascular Treatment Plus Stenting in Patients with Acute Ischemic Stroke [J].
Dorado, Laura ;
Castano, Carlos ;
Millan, Monica ;
Aleu, Aitziber ;
Perez de la Ossa, Natalia ;
Gomis, Meritxell ;
Lopez-Cancio, Elena ;
Vivas, Elio ;
Rodriguez-Campello, Ana ;
Castellanos, Mar ;
Davalos, Antoni .
JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2013, 22 (08) :1326-1331
[10]   Randomized Assessment of Rapid Endovascular Treatment of Ischemic Stroke [J].
Goyal, M. ;
Demchuk, A. M. ;
Menon, B. K. ;
Eesa, M. ;
Rempel, J. L. ;
Thornton, J. ;
Roy, D. ;
Jovin, T. G. ;
Willinsky, R. A. ;
Sapkota, B. L. ;
Dowlatshahi, D. ;
Frei, D. F. ;
Kamal, N. R. ;
Montanera, W. J. ;
Poppe, A. Y. ;
Ryckborst, K. J. ;
Silver, F. L. ;
Shuaib, A. ;
Tampieri, D. ;
Williams, D. ;
Bang, O. Y. ;
Baxter, B. W. ;
Burns, P. A. ;
Choe, H. ;
Heo, J. -H. ;
Holmstedt, C. A. ;
Jankowitz, B. ;
Kelly, M. ;
Linares, G. ;
Mandzia, J. L. ;
Shankar, J. ;
Sohn, S. -I. ;
Swartz, R. H. ;
Barber, P. A. ;
Coutts, S. B. ;
Smith, E. E. ;
Morrish, W. F. ;
Weill, A. ;
Subramaniam, S. ;
Mitha, A. P. ;
Wong, J. H. ;
Lowerison, M. W. ;
Sajobi, T. T. ;
Hill, M. D. .
NEW ENGLAND JOURNAL OF MEDICINE, 2015, 372 (11) :1019-1030