Compressive strength equation for GFRP square tube columns
被引:67
作者:
Cardoso, Daniel C. T.
[1
,2
,3
]
Harries, Kent A.
[1
]
Batista, Eduardo de M.
[2
]
机构:
[1] Univ Pittsburgh, Dept Civil & Environm Engn, Pittsburgh, PA 15261 USA
[2] Univ Fed Rio de Janeiro, COPPE, Civil Engn Program, BR-21945972 Rio De Janeiro, Brazil
[3] CAPES Fdn, Minist Educ Brazil, BR-70040020 Brasilia, DF, Brazil
关键词:
Buckling;
Strength;
Analytical modeling;
Pultrusion;
COMPOSITE COLUMNS;
FRP COLUMNS;
PREDICTION;
BEHAVIOR;
DESIGN;
D O I:
10.1016/j.compositesb.2013.10.057
中图分类号:
T [工业技术];
学科分类号:
08 ;
摘要:
In this paper, the development of a rational and comprehensive equation to determine the strength of glass fiber reinforced polymer (GFRP) pultruded square tube columns under concentric compression is presented. Material characterization and compression tests on stubs and columns were carried out in order to establish in situ properties. Square tube columns having different lengths and sections, resulting in a range of combinations of global and sectional slenderness, were tested. Material properties, critical loads, compressive strengths and failure modes are reported and comments are made on observed post-buckling behavior and interaction between crushing, local and global buckling. Column and wall imperfections are estimated and used as inputs to the proposed equation. The strength curve is plotted along with the test results, showing good agreement. Finally, a step-by-step example is presented. (C) 2013 Elsevier Ltd. All rights reserved.