摘要
This paper presents an approximate formula for the peak value of the lightning-induced voltages in an aerial line over high resistivity soils. In its derivation, it is considered the transmission line return stroke model (TL) and a trapezoidal current waveform. The formula is an improved version of a previously expression presented by the authors, whereas its validity range is extended from 1000 Ohms.m to 10000 Ohms.m. The paper also illustrates the formula application in the assessment of the indirect lightning performance of overhead distribution lines.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 50 条
  • [1] An Approximate Formula for the Peak Value of Lightning-Induced Voltages in Overhead Lines
    Saldanha Paulino, Jose Osvaldo
    Barbosa, Celio Fonseca
    Lopes, Ivan J. S.
    Boaventura, Wallace do Couto
    IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (02) : 843 - 851
  • [2] On Lightning-Induced Voltages in Overhead Lines Over High-Resistivity Ground
    Saldanha Paulino, Jose Osvaldo
    Barbosa, Cello Fonseca
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2019, 61 (05) : 1499 - 1506
  • [3] The Peak Value of Lightning-Induced Voltages in Overhead Lines Considering the Ground Resistivity and Typical Return Stroke Parameters
    Paulino, Jose Osvaldo S.
    Barbosa, Celio Fonseca
    Lopes, Ivan J. S.
    Boaventura, Wallace do Couto
    IEEE TRANSACTIONS ON POWER DELIVERY, 2011, 26 (02) : 920 - 927
  • [4] LIGHTNING-INDUCED VOLTAGES ON OVERHEAD LINES
    NUCCI, CA
    RACHIDI, F
    IANOZ, MV
    MAZZETTI, C
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1993, 35 (01) : 75 - 86
  • [5] LIGHTNING-INDUCED VOLTAGES ON MULTICONDUCTOR OVERHEAD LINES
    CHOWDHURI, P
    IEEE TRANSACTIONS ON POWER DELIVERY, 1990, 5 (02) : 658 - 667
  • [6] ANALYSIS OF LIGHTNING-INDUCED VOLTAGES ON OVERHEAD LINES
    CHOWDHURI, P
    IEEE TRANSACTIONS ON POWER DELIVERY, 1989, 4 (01) : 479 - 492
  • [7] Analysis of Lightning-Induced Voltages in Overhead Transmission Lines
    Boumaiza, Mostefa
    Labed, Djamel
    TECHNOLOGIES AND MATERIALS FOR RENEWABLE ENERGY, ENVIRONMENT AND SUSTAINABILITY (TMREES14 - EUMISD), 2014, 50 : 41 - 49
  • [8] Influence of a lossy ground on lightning-induced voltages on overhead lines
    Swiss Federal Inst of Technology, Lausanne, Switzerland
    IEEE Trans Electromagn Compat, 3 (250-264):
  • [9] Influence of a lossy ground on lightning-induced voltages on overhead lines
    Rachidi, F
    Nucci, CA
    Ianoz, M
    Mazzetti, C
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1996, 38 (03) : 250 - 264
  • [10] Lightning-induced voltages on overhead lines over irregular terrains
    Soto, Edison
    Perez, Ernesto
    ELECTRIC POWER SYSTEMS RESEARCH, 2019, 176