Visual and Refractive Outcomes of Femtosecond Lenticule Extraction and Small-Incision Lenticule Extraction for Myopia

被引:133
|
作者
Kamiya, Kazutaka [1 ]
Shimizu, Kimiya [1 ]
Igarashi, Akihito [1 ]
Kobashi, Hidenaga [1 ]
机构
[1] Kitasato Univ, Sch Med, Dept Ophthalmol, Kanagawa, Japan
关键词
LASER; SURGERY; KERATOMILEUSIS; ASTIGMATISM; EFFICACY;
D O I
10.1016/j.ajo.2013.08.011
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the visual and refractive outcomes of femtosecond lenticule extraction (FLEx) and small-incision lenticule extraction (SMILE) in eyes with myopia. DESIGN: Prospective, randomized, masked clinical trial with intraindividual comparison. METHODS: This study evaluated 52 eyes of 26 consecutive patients with spherical equivalents of -4.19 +/- 1.65 diopters (D) (mean standard +/- deviation) who underwent FLEx in 1 eye and SMILE in the other eye by randomized assignment. Before surgery, and 1 week and 1, 3, and 6 months after surgery, we assessed safety, efficacy, predictability, stability, and adverse events of the 2 surgical techniques. RESULTS: LogMAR uncorrected and corrected distance visual acuity was, respectively, -0.17 +/- 0.10, -0.20 +/- 0.07 in the FLEx group and -0.15 +/- 0.10, -0.19 +/- 0.07 in the SMILE group 6 months postoperatively. In the FLEx and SMILE groups 6 months postoperatively, 96% and 100% of eyes, respectively, were within 0.5 D of the targeted spherical equivalent correction. Changes of -0.02 +/- 0.39 D and 0.00 +/- 0.30 D occurred in manifest refraction from 1 week to 6 months in the FLEx and SMILE groups, respectively. No clinically significant complications occurred in the FLEx or the SMILE group. CONCLUSIONS: Both FLEx and SMILE performed well in the correction of myopia throughout the 6-month observation period. FLEx may be essentially equivalent to SMILE in terms of safety, efficacy, predictability, and stability, suggesting that the presence or absence of lifting the flap does not significantly affect these visual and refractive outcomes. (C) 2014 by Elsevier Inc. All rights reserved.
引用
收藏
页码:128 / 134
页数:7
相关论文
共 50 条
  • [31] Small-incision lenticule extraction for correction of refractive error after 2 years of follow-up
    Shuber, Hassenien S.
    Alhamami, Hussein A.
    Alasadi, Salah Z.
    AFRICAN VISION AND EYE HEALTH JOURNAL, 2021, 80 (01):
  • [32] Influence of intraocular astigmatism on the correction of myopic astigmatism by femtosecond laser small-incision lenticule extraction
    Qian, Yishan
    Huang, Jia
    Chu, Renyuan
    Zhao, Jing
    Li, Meiyan
    Zhou, Xingtao
    Olszewski, Emily
    Wang, Yutung
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (05) : 1057 - 1064
  • [33] Long-Term Refractive Outcome of Small Incision Lenticule Extraction in Very High Myopia
    Elmassry, Ahmed
    Ibrahim, Osama
    Osman, Ihab
    Said, Amr
    Sabry, Moataz
    Seifelnasr, Mohammed
    Gaballah, Karim
    Abdalla, Moones
    CORNEA, 2020, 39 (06) : 669 - 673
  • [34] Comparison of corneal aberrations and refractive outcomes after small-incision lenticule extraction and femtosecond-assisted laser-assisted in situ keratomileusis
    Zhang, Riping
    Wei, Heng
    Jhanji, Vishal
    Sun, Lixia
    Li, Jinyu
    Jiang, Jingjing
    Zhuang, Suoqing
    Zhang, Mingzhi
    INTERNATIONAL OPHTHALMOLOGY, 2021, 41 (07) : 2521 - 2531
  • [35] Outcomes of bioptics with small-incision lenticule extraction as a sequential treatment after implantable collamer lens for management of extreme myopia
    Brar, Sheetal
    Batra, Akanksha
    Shah, Mamta Lakhana
    Ganesh, Sri
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (06) : 741 - 747
  • [36] One-Year Results of Small Incision Lenticule Extraction (SMILE) in Myopia
    Kunert, K. S.
    Melle, J.
    Sekundo, W.
    Dawczynski, J.
    Blum, M.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2015, 232 (01) : 67 - 71
  • [37] Enhancement of femtosecond lenticule extraction for visual symptomatic eye after myopia correction
    Zhao, Jing
    Yao, Peijun
    Chen, Zhi
    Li, Meiyan
    Shen, Yang
    Miao, Huamao
    Zhou, Xingtao
    BMC OPHTHALMOLOGY, 2014, 14
  • [38] Comparison of corneal sensitivity between FS-LASIK and femtosecond lenticule extraction (ReLEx flex) or small-incision lenticule extraction (ReLEx smile) for myopic eyes
    Wei, Shengsheng
    Wang, Yan
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (06) : 1645 - 1654
  • [39] Combined Bacterial and Herpes Simplex Virus Keratitis following Small-Incision Lenticule Extraction for the Correction of Myopia
    Ramirez-Miranda, Arturo
    Mangwani-Mordani, Simran
    Quiroz-Casian, Natalia
    Oliva-Bienzobas, Valeria
    Cabral-Macias, Jesus
    Navas, Alejandro
    Graue-Hernandez, Enrique O.
    CASE REPORTS IN OPHTHALMOLOGY, 2021, 12 (01): : 227 - 231
  • [40] Effect of location of opening incision on astigmatic correction after small-incision lenticule extraction
    Chan, Tommy C. Y.
    Ng, Alex L. K.
    Cheng, George P. M.
    Wang, Zheng
    Woo, Victor C. P.
    Jhanji, Vishal
    SCIENTIFIC REPORTS, 2016, 6