The Applicability of Ganglion Cell Complex Parameters Determined From SD-OCT Images to Detect Glaucomatous Eyes

被引:51
作者
Arintawati, Paramastri [1 ]
Sone, Takashi [1 ]
Akita, Tomoyuki [2 ]
Tanaka, Junko [2 ]
Kiuchi, Yoshiaki [1 ]
机构
[1] Hiroshima Univ, Dept Ophthalmol & Visual Sci, Grad Sch Biomed Sci, Hiroshima 7348551, Japan
[2] Hiroshima Univ, Dept Epidemiol Infect Dis Control & Prevent, Grad Sch Biomed Sci, Hiroshima 7348551, Japan
关键词
GCC; RNFL; preperimetric-perimetric glaucoma; OPTICAL COHERENCE TOMOGRAPHY; RETINAL NERVE-FIBER; LAYER THICKNESS; MACULAR VOLUME; VISUAL-FIELD; DOMAIN;
D O I
10.1097/IJG.0b013e318259b2e1
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:To determine whether the thicknesses of the different parameters of the ganglion cell complex (GCC) and peripapillary retinal nerve fiber layer can be used to differentiate eyes with glaucoma from normal eyes.Methods:Two hundred sixty-one eyes, including 68 normal eyes and 32 preperimetric glaucoma, 81 early glaucoma, and 80 advanced glaucoma were analyzed in the present study. The thicknesses of the GCC and retinal nerve fiber layer were measured using RTVue spectral-domain optical coherence tomographic (SD-OCT) images. The area under the receiver operating characteristic (AUROC) curve and sensitivities at fixed specificities were calculated for each parameter. A logistic regression analysis was used to determine the risk factors for glaucoma.Results:The 2 largest AUROC curves for all glaucoma stages were those for the GCC parameters. The global loss volume (GLV) was always one of the 2 highest values of the AUROC curve. The GLV also had the highest sensitivity at a fixed specificity to identify glaucoma at early and advanced stage. The focal loss volume (FLV) had the largest AUROC curve value and the highest sensitivity at a fixed specificity for advanced glaucoma. The logistic regression analysis showed that the GLV was one of the factors that predicted preperimetric glaucoma [odds ratio (OR)=1.74] and early glaucoma (OR=1.22), whereas the FLV was useful for detecting advanced glaucoma (OR=2.32).Conclusions:The SD-OCT-derived macular GCC parameters can be used to detect preperimetric and perimetric glaucoma. The new GCC parameters, GLV and FLV, performed well in discriminating glaucomatous eyes from normal eyes.
引用
收藏
页码:713 / 718
页数:6
相关论文
共 19 条
  • [1] Relationship between visual field sensitivity and retinal nerve fiber layer thickness as measured by optical coherence tomography
    Ajtony, Csilla
    Balla, Zsolt
    Somoskeoy, Szabolcs
    Kovacs, Balint
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (01) : 258 - 263
  • [2] Correlation among retinal thickness, optic disc, and visual field in glaucoma patients and suspects: A pilot study
    Asrani, S
    Challa, P
    Herndon, L
    Lee, P
    Stinnett, S
    Allingham, RR
    [J]. JOURNAL OF GLAUCOMA, 2003, 12 (02) : 119 - 128
  • [3] Reproducibility of Retinal Nerve Fiber Layer and Macular Thickness Measurement with the RTVue-100 Optical Coherence Tomograph
    Garas, Anita
    Vargha, Peter
    Hollo, Gabor
    [J]. OPHTHALMOLOGY, 2010, 117 (04) : 738 - 746
  • [4] Greenfield DS, 2003, ARCH OPHTHALMOL-CHIC, V121, P41
  • [5] A Test of a Linear Model of Glaucomatous Structure-Function Loss Reveals Sources of Variability in Retinal Nerve Fiber and Visual Field Measurements
    Hood, Donald C.
    Anderson, Susan C.
    Wall, Michael
    Raza, Ali S.
    Kardon, Randy H.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (09) : 4254 - 4266
  • [6] Huang D, 2009, GLAUCOMA, VVIII, P3
  • [7] Structure-Function Relationship and Diagnostic Value of Macular Ganglion Cell Complex Measurement Using Fourier-Domain OCT in Glaucoma
    Kim, Na Rae
    Lee, Eun Suk
    Seong, Gong Je
    Kim, Ji Hyun
    An, Hyong Gin
    Kim, Chan Yun
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (09) : 4646 - 4651
  • [8] Analysis of macular volume in normal and glaucomatous eyes using optical coherence tomography
    Lederer, DE
    Schuman, JS
    Hertzmark, E
    Heltzer, J
    Velazques, LJ
    Fujimoto, JG
    Mattox, C
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 135 (06) : 838 - 843
  • [9] Comparison of macular and peripapillary measurements for the detection of glaucoma - An optical coherence tomography study
    Leung, CKS
    Chan, WM
    Yung, WH
    Ng, ACK
    Woo, J
    Tsang, MK
    Tse, RKK
    [J]. OPHTHALMOLOGY, 2005, 112 (03) : 391 - 400
  • [10] Spectral-domain Optical Coherence Tomography Measurement of Macular Volume for Diagnosing Glaucoma
    Mori, Satoshi
    Hangai, Masanori
    Sakamoto, Atsushi
    Yoshimura, Nagahisa
    [J]. JOURNAL OF GLAUCOMA, 2010, 19 (08) : 528 - 534