Liver: T2-weighted MR imaging with breath-hold fast-recovery optimized fast spin-echo compared with breath-hold half-Fourier and non-breath-hold respiratory-triggered fast spin-echo pulse sequences

被引:37
作者
Augui, J
Vignaux, O
Argaud, C
Coste, J
Gouya, H
Legmann, P
机构
[1] Univ Paris 05, Hop Cochin, Dept Radiol, F-75674 Paris 14, France
[2] Univ Paris 05, Hop Cochin, Dept Biostat, F-75674 Paris, France
[3] GE Med Syst, Buc, France
关键词
liver neoplasms; MR; magnetic resonance (MR); comparative studies; pulse sequences;
D O I
10.1148/radiol.2233011011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
At liver magnetic resonance (MR) imaging in 38 patients, a breath-hold T2-weighted fast spin-echo (SE) pulse sequence optimized with fast recovery was compared with a conventional respiratory-triggered fast SE sequence and a breath-hold single-shot fast SE sequence. Mean signal-to-noise ratios for liver and contrast-to-noise ratios for hepatic lesions were higher with the breath-hold fast-recovery fast SE sequence than with the respiratory-triggered fast SE sequence (P < .05). Breath-hold fast-recovery images displayed better lesion clarity than did single-shot fast SE images (P < .05) and fewer image artifacts than did respiratory-triggered fast SE images (P < .05). The ability to determine lesion size and the overall image quality was best with the breath-hold fast-recovery sequence (P < .05). These results may justify use of the breath-hold fast-recovery fast SE pulse sequence for first-line T2-weighted MR imaging of the liver. (C) RSNA, 2002.
引用
收藏
页码:853 / 859
页数:7
相关论文
共 15 条
[1]   MR of focal liver lesions: Comparison of breath-hold and non-breath-hold hybrid RARE and conventional spin-echo T2-weighted pulse sequences [J].
Carpenter, KD ;
Macaulay, SE ;
Schulte, SJ ;
Obregon, RG ;
Nelson, RC ;
Simon, HE ;
Schmiedl, UP .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (04) :596-602
[2]   Hepatic T2-weighted MRI: A prospective comparison of sequences, including breath-hold, half-Fourier turbo spin echo (HASTE) [J].
Coates, GG ;
Borrello, JA ;
McFarland, EG ;
Mirowitz, SA ;
Brown, JJ .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (03) :642-649
[3]   FACTORS INFLUENCING CONTRAST IN FAST SPIN-ECHO MR IMAGING [J].
CONSTABLE, RT ;
ANDERSON, AW ;
ZHONG, J ;
GORE, JC .
MAGNETIC RESONANCE IMAGING, 1992, 10 (04) :497-511
[4]   THE LOSS OF SMALL OBJECTS IN VARIABLE TE IMAGING - IMPLICATIONS FOR FSE, RARE, AND EPI [J].
CONSTABLE, RT ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (01) :9-24
[5]   Liver masses: Replacement of conventional T2-weighted spin-echo MR imaging with breath-hold MR imaging [J].
Gaa, J ;
Hatabu, H ;
Jenkins, RL ;
Finn, JP ;
Edelman, RR .
RADIOLOGY, 1996, 200 (02) :459-464
[6]   Single breath-hold T2-weighted MR imaging of the liver: Value of single-shot fast spin-echo and multishot spin-echo echoplanar imaging [J].
Hori, M ;
Murakami, T ;
Kim, T ;
Kanematsu, M ;
Tsuda, K ;
Takahashi, S ;
Takamura, M ;
Hoshi, H ;
Nakamura, H .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (05) :1423-1431
[7]   Focal hepatic lesion detection: Comparison of four fat-suppressed T2-weighted MR imaging pulse sequences [J].
Kanematsu, M ;
Hoshi, H ;
Itoh, K ;
Murakami, T ;
Hori, M ;
Kondo, H ;
Yokoyama, R ;
Nakamura, H .
RADIOLOGY, 1999, 211 (02) :363-371
[8]   Focal hepatic lesion detection: Comparison of four T2-weighted MR imaging pulse sequences [J].
Kanematsu, M ;
Hoshi, H ;
Murakami, T ;
Inaba, Y ;
Hori, M ;
Nandate, Y ;
Yokoyama, R ;
Nakamura, H .
RADIOLOGY, 1998, 206 (01) :167-175
[9]   Fast T2-weighted liver MR imaging: comparison among breath-hold turbo-spin-echo, HASTE, and inversion recovery (IR) HASTE sequences [J].
Lee, MG ;
Jeong, YK ;
Kim, JC ;
Kang, EM ;
Kim, PN ;
Auh, YH ;
Chien, D ;
Laub, G .
ABDOMINAL IMAGING, 2000, 25 (01) :93-99
[10]   COMPARISON OF BREATH-HOLD FAST SPIN-ECHO AND CONVENTIONAL SPIN-ECHO PULSE SEQUENCES FOR T2-WEIGHTED MR-IMAGING OF LIVER-LESIONS [J].
RYDBERG, JN ;
LOMAS, DJ ;
COAKLEY, KJ ;
HOUGH, DM ;
EHMAN, RL ;
RIEDERER, SJ .
RADIOLOGY, 1995, 194 (02) :431-437