Magnetic solid-phase extraction based on Fe3O4/graphene oxide nanoparticles for the determination of malachite green and crystal violet in environmental water samples by HPLC

被引:44
作者
Zhang, Leilei [1 ]
Zhang, Yiying [1 ]
Tang, Yurong [1 ]
Li, Xiaorong [2 ]
Zhang, Xinfeng [1 ]
Li, Chaobi [1 ]
Xu, Shuxia [3 ,4 ]
机构
[1] Chengdu Univ Technol, Coll Mat & Chem & Chem Engn, Chengdu, Sichuan, Peoples R China
[2] Shaanxi Univ Chinese Med, Coll Pharm, Xian Yang, Peoples R China
[3] Chengdu Univ Technol, Coll Environm & Ecol, Chengdu, Sichuan, Peoples R China
[4] Chengdu Univ Technol, State Environm Protect Key Lab Synerget Control &, Chengdu, Sichuan, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
Magnetic solid-phase extraction; Fe3O4; graphene oxide magnetic nanoparticles; water samples; HPLC; PERFORMANCE LIQUID-CHROMATOGRAPHY; TANDEM MASS-SPECTROMETRY; GRAPHENE OXIDE; SPECTROPHOTOMETRIC DETERMINATION; LEUCOMALACHITE GREEN; SENSITIVE DETECTION; REMOVAL; PRECONCENTRATION; MICROEXTRACTION; NANOCOMPOSITE;
D O I
10.1080/03067319.2018.1441837
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work describes a magnetic Fe3O4/graphene oxide (GO)-based solid-phase extraction (MSPE) technique for high performance liquid chromatography (HPLC) detection of malachite green (MG) and crystal violet (CV) in environmental water samples. Fe3O4/ GO magnetic nanoparticles were synthesised by a chemical co-precipitation method and characterised by scanning electron micrograph, transmission electron microscope, Fourier transform infrared spectroscopy, X-ray photoelectron spectroscopy and surface area analyser. The prepared Fe3O4/GO magnetic nanoparticles were used as the adsorbents of MSPE for MG and CV. By coupling with HPLC, a sensitive and cost-effective method for simultaneous determination of MG and CV was developed. The important parameters including the amount of Fe3O4/GO, pH of the sample solution, extraction time, salt effect, the type and volume of desorption solvent were investigated in detail. Under optimised conditions, the calibration curves were linear in the concentration range of 0.5-200 g L-1, and the limits of detection were 0.091 and 0.12 g L-1 for MG and CV, respectively. Finally, the established MSPE-HPLC method was successfully applied to determine MG and CV in environmental water samples with the recoveries ranging from 91.5% to116.7%.
引用
收藏
页码:215 / 228
页数:14
相关论文
共 33 条
  • [1] Preconcentration and spectrophotometric determination of low concentrations of malachite green and leuco-malachite green in water samples by high performance solid phase extraction using maghemite nanoparticles
    Afkhami, Abbas
    Moosavi, Razieh
    Madrakian, Tayyebeh
    [J]. TALANTA, 2010, 82 (02) : 785 - 789
  • [2] POSTCOLUMN REACTION FOR SIMULTANEOUS ANALYSIS OF CHROMATIC AND LEUCO FORMS OF MALACHITE GREEN AND CRYSTAL VIOLET BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PHOTOMETRIC DETECTION
    ALLEN, JL
    MEINERTZ, JR
    [J]. JOURNAL OF CHROMATOGRAPHY, 1991, 536 (1-2): : 217 - 222
  • [3] Simultaneous spectrophotometric determination of trace amount of malachite green and crystal violet in water after cloud point extraction using partial least squares regression
    An, Lin
    Deng, Jian
    Zhou, Liang
    Li, Hui
    Chen, Fei
    Wang, Hui
    Liu, Yating
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2010, 175 (1-3) : 883 - 888
  • [4] Magnetic nanoparticle based dispersive micro-solid-phase extraction for the determination of malachite green in water samples: optimized experimental design
    Asfaram, Arash
    Ghaedi, Mehrorang
    Goudarzi, Alireza
    Soylak, Mustafa
    Langroodi, Sanaz Mehdizadeh
    [J]. NEW JOURNAL OF CHEMISTRY, 2015, 39 (12) : 9813 - 9823
  • [5] n-Octadecylphosphonic acid grafted mesoporous magnetic nanoparticle: Preparation, characterization, and application in magnetic solid-phase extraction
    Ding, Jun
    Gao, Qiang
    Luo, Dan
    Shi, Zhi-Guo
    Feng, Yu-Qi
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (47) : 7351 - 7358
  • [6] Confirmatory analysis of malachite green, leucomalachite green, crystal violet and leucocrystal violet in salmon by liquid chromatography-tandem mass spectrometry
    Dowling, Geraldine
    Mulder, Patrick P. J.
    Duffy, Conor
    Regan, Liam
    Smyth, Malcolm R.
    [J]. ANALYTICA CHIMICA ACTA, 2007, 586 (1-2) : 411 - 419
  • [7] Ferrofluid based dispersive-solid phase extraction for spectrophotometric determination of dyes
    Farahani, Malihe Davudabadi
    Shemirani, Farzaneh
    [J]. JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2013, 407 : 250 - 254
  • [8] Adsorption and removal of tetracycline antibiotics from aqueous solution by graphene oxide
    Gao, Yuan
    Li, Yan
    Zhang, Liang
    Huang, Hui
    Hu, Junjie
    Shah, Syed Mazhar
    Su, Xingguang
    [J]. JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2012, 368 : 540 - 546
  • [9] Application of ionic liquid-based microwave-assisted extraction of malachite green and crystal violet from water samples
    Gao, Zhanqi
    Liu, Tingfeng
    Yan, Xiaoju
    Sun, Cheng
    He, Huan
    Yang, Shaogui
    [J]. JOURNAL OF SEPARATION SCIENCE, 2013, 36 (06) : 1112 - 1118
  • [10] Application of Micro-cloud point extraction for spectrophotometric determination of Malachite green, Crystal violet and Rhodamine B in aqueous samples
    Ghasemi, Elham
    Kaykhaii, Massoud
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2016, 164 : 93 - 97