Biomedical sensors using optical fibres

被引:54
作者
Mignani, AG
Baldini, F
机构
[1] Ist. di Ric. Sulle Onde E., I-50127, Firenze
关键词
DYNAMIC LIGHT-SCATTERING; AFFINITY SENSOR; EYE LENS; FIBER; TISSUE; TEMPERATURE; PRESSURE; GLUCOSE; SYSTEM; OXYGEN;
D O I
10.1088/0034-4885/59/1/001
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Optical techniques developed for sensing purposes proved to be essential in many application fields, ranging from aerospace, industry, process control, to security, and also medicine. The capabilities of these sensors are generally enhanced when a bulk-optical configuration is replaced by optical fibre technology. In the past few years, research programmes and also the market for fibre sensors have assumed a relevant role. This is undoubtedly due to the growing interest in optoelectronics, but also to the very satisfactory performance and reliability that optical fibre sensors are now able to provide. This paper focuses on the advantages that optical fibre sensors offer to the biomedical field, recalls the basic working principles of sensing, and discusses some examples.
引用
收藏
页码:1 / 28
页数:28
相关论文
共 79 条
[1]   CONTINUOUS MONITORING OF TISSUE PH WITH A FIBEROPTIC CONJUNCTIVAL SENSOR [J].
ABRAHAM, E ;
FINK, SE ;
MARKLE, DR ;
PINHOLSTER, G ;
TSANG, M .
ANNALS OF EMERGENCY MEDICINE, 1985, 14 (09) :840-844
[2]  
ANDERSON CD, 1992, P SOC PHOTO-OPT INS, V1648, P116, DOI 10.1117/12.58292
[3]   MICROEMULSION CHARACTERIZATION BY THE USE OF A NONINVASIVE BACKSCATTER FIBER OPTIC PROBE [J].
ANSARI, RR ;
DHADWAL, HS ;
CHEUNG, HM ;
MEYER, WV .
APPLIED OPTICS, 1993, 32 (21) :3822-3827
[4]  
ARTJUSHENKO VG, 1993, P SPIE BIOCH MED SEN, V2085, P137
[5]   CONTROLLED-PORE GLASSES EMBEDDED IN PLASTIC OPTICAL FIBERS FOR GASTRIC PH SENSING PURPOSES [J].
BALDINI, F ;
BRACCI, S ;
COSI, F ;
BECHI, P ;
PUCCIANI, F .
APPLIED SPECTROSCOPY, 1994, 48 (05) :549-552
[6]   IN-VIVO OPTICAL-FIBER PH SENSOR FOR GASTROESOPHAGEAL MEASUREMENTS [J].
BALDINI, F ;
BECHI, P ;
BRACCI, S ;
COSI, F ;
PUCCIANI, F .
SENSORS AND ACTUATORS B-CHEMICAL, 1995, 29 (1-3) :164-168
[7]  
Baraga J. J., 1992, Lasers in the Life Sciences, V5, P13
[8]  
BARYSHEV MV, 1994, P SOC PHOTO-OPT INS, V2084, P106, DOI 10.1117/12.167292
[9]   LONG-TERM AMBULATORY ENTEROGASTRIC REFLUX MONITORING - VALIDATION OF A NEW FIBEROPTIC TECHNIQUE [J].
BECHI, P ;
PUCCIANI, F ;
BALDINI, F ;
COSI, F ;
FALCIAI, R ;
MAZZANTI, R ;
CASTAGNOLI, A ;
PASSERI, A ;
BOSCHERINI, S .
DIGESTIVE DISEASES AND SCIENCES, 1993, 38 (07) :1297-1306
[10]  
Brenci M., 1986, International Journal of Optical Sensors, V1, P163