Functional results of lower extremity lengthening by motorized intramedullary nails

被引:31
作者
Dincyurek, Hakan [1 ]
Kocaoglu, Mehmet [2 ]
Eralp, I. Levent [3 ]
Bilen, F. Erkal [2 ]
Dikmen, Goksel [3 ]
Eren, Ilker [3 ]
机构
[1] Burhan Nalbantoglu State Hosp, Dept Orthoped & Traumatol, Nicosia, Cyprus
[2] Mem Hosp, Dept Orthoped & Traumatol, Istanbul, Turkey
[3] Istanbul Univ, Istanbul Tip Fak, Ortopedi & Traymatol Anabilim Dali, Istanbul, Turkey
关键词
Complication; distraction; external fixator; intramedullary femoral nails; limb lengthening; SKELETAL KINETIC DISTRACTOR; CALLUS DISTRACTION; EXTERNAL FIXATOR; BONE TRANSPORT; COMPLICATIONS; OSTEOGENESIS; DEFORMITY; RECONSTRUCTION; EXPERIENCES; DISCREPANCY;
D O I
10.3944/AOTT.2012.2671
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: The aim of this study was to evaluate the outcome of patients undergoing limb lengthening using motorized intramedullary nails. Methods: This study included eleven femora and 4 tibiae from 14 patients (9 male, 5 female; mean age: 26.9 years; range: 14 to 51 years) who underwent limb lengthening using motorized intramedullary femoral nails (Fitbone (R) TAA). Average preoperative limb shortening was 4.9 (range: 2.5 to 7.5) cm. Distraction was initiated on the seventh postoperative day. Serial radiographs and Paley's bone and functional outcome scoring systems were used to evaluate the results. Results: Mean follow-up period was 33.5 (range: 7 to 88) months. Mean distraction index value was 1.2 (range: 0.7 to 2.1) days/mm and mean bone-healing index value was 43.7 (range: 13.8 to 144) days/cm. The average lengthening achieved was 51.7 (range: 25 to 75) mm. The distraction mechanism of the nail did not function properly in two patients, restricted transient knee motion was observed in four patients, and delayed consolidation was observed in four patients. Other complications included valgus deformities and superficial infections surrounding the antenna of the intramedullary nail, as well as femur fractures at the proximal end of the nail. Bone scores were excellent in 11 segments and were good in one segment. Functional scores were excellent for all 12 patients. Conclusion: While usual complications related to the external fixators, such as pin-track infections and mobilization difficulties were not encountered, the development of additional complications such as dysfunction of the distraction mechanism should be monitored with the use of motorized intramedullary nails in limb lengthening.
引用
收藏
页码:42 / 49
页数:8
相关论文
共 50 条
  • [31] Lower limb lengthening and deformity correction using the Fitbone motorized nail system in the adolescent patient
    Al-Sayyad, Mohammed J.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2012, 21 (02): : 131 - 136
  • [32] EXTREMITY LENGTHENING - RESULTS AND COMPLICATIONS WITH THE ORTHOFIX SYSTEM
    GUIDERA, KJ
    HESS, WF
    HIGHHOUSE, KP
    OGDEN, JA
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1991, 11 (01) : 90 - 94
  • [33] Motorisierte intramedulläre VerlängerungsnägelMotorized intramedullary lengthening nails
    Christian Krettek
    Der Unfallchirurg, 2018, 121 (11): : 858 - 859
  • [34] Intramedullary limb lengthening with the Intramedullary Skeletal Kinetic Distractor in the lower limb
    Schiedel, F. M.
    Pip, S.
    Wacker, S.
    Poepping, J.
    Tretow, H.
    Leidinger, B.
    Roedl, R.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (06): : 788 - 792
  • [35] Psychological and orthopedic outcomes after stature lengthening surgery using intramedullary nails
    Assayag, Michael
    Buksbaum, Joshua R.
    Khabyeh-Hasbani, Nathan
    Westrich, EllenKatz
    Fragomen, Austin T.
    Rozbruch, S. Robert
    JOURNAL OF LIMB LENGTHENING & RECONSTRUCTION, 2020, 6 (01) : 28 - 32
  • [36] Multicentre Review of Intramedullary Lengthening Nails: A Middle-Income Country Perspective
    Harrison, William D.
    Laubscher, Maritz
    Al Saifi, Saleh
    Abdelaziz, Ahmed
    Barnard, Annette-Christi
    Birkholtz, Franz
    Ferreira, Nando
    JOURNAL OF LIMB LENGTHENING & RECONSTRUCTION, 2021, 7 (02) : 119 - 124
  • [37] Clinical Results and Complications of Lower Limb Lengthening for Fibular Hemimelia: A Report of Eight Cases
    Mishima, Kenichi
    Kitoh, Hiroshi
    Iwata, Koji
    Matsushita, Masaki
    Nishida, Yoshihiro
    Hattori, Tadashi
    Ishiguro, Naoki
    MEDICINE, 2016, 95 (21)
  • [38] Femoral lengthening with a motorized intramedullary nail A matched-pair comparison with external ring fixator lengthening in 30 cases
    Horn, Joachim
    Grimsrud, Oyvind
    Sgard, Anita Hoddevik Dag
    Huhnstock, Stefan
    Steen, Harald
    ACTA ORTHOPAEDICA, 2015, 86 (02) : 248 - 256
  • [39] Osteotomy Site Venting Enhances Femoral Bone Consolidation With Magnetic Intramedullary Lengthening Nails
    Gigi, Roy
    Weil, Yehuda
    Amar, Eyal
    Sigal, Amit
    Ovadia, Dror
    Herzenberg, John E.
    Segev, Eitan
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2024, 482 (11) : 2075 - 2085
  • [40] Trigonometric Analysis of the Mechanical Axis Deviation Induced by Telescopic Intramedullary Femoral Lengthening Nails
    Burghardt, Rolf D.
    Herzenberg, John E.
    Burghardt, Manfred H.
    JOURNAL OF APPLIED BIOMECHANICS, 2011, 27 (04) : 385 - 391