Functional results of lower extremity lengthening by motorized intramedullary nails

被引:32
作者
Dincyurek, Hakan [1 ]
Kocaoglu, Mehmet [2 ]
Eralp, I. Levent [3 ]
Bilen, F. Erkal [2 ]
Dikmen, Goksel [3 ]
Eren, Ilker [3 ]
机构
[1] Burhan Nalbantoglu State Hosp, Dept Orthoped & Traumatol, Nicosia, Cyprus
[2] Mem Hosp, Dept Orthoped & Traumatol, Istanbul, Turkey
[3] Istanbul Univ, Istanbul Tip Fak, Ortopedi & Traymatol Anabilim Dali, Istanbul, Turkey
关键词
Complication; distraction; external fixator; intramedullary femoral nails; limb lengthening; SKELETAL KINETIC DISTRACTOR; CALLUS DISTRACTION; EXTERNAL FIXATOR; BONE TRANSPORT; COMPLICATIONS; OSTEOGENESIS; DEFORMITY; RECONSTRUCTION; EXPERIENCES; DISCREPANCY;
D O I
10.3944/AOTT.2012.2671
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: The aim of this study was to evaluate the outcome of patients undergoing limb lengthening using motorized intramedullary nails. Methods: This study included eleven femora and 4 tibiae from 14 patients (9 male, 5 female; mean age: 26.9 years; range: 14 to 51 years) who underwent limb lengthening using motorized intramedullary femoral nails (Fitbone (R) TAA). Average preoperative limb shortening was 4.9 (range: 2.5 to 7.5) cm. Distraction was initiated on the seventh postoperative day. Serial radiographs and Paley's bone and functional outcome scoring systems were used to evaluate the results. Results: Mean follow-up period was 33.5 (range: 7 to 88) months. Mean distraction index value was 1.2 (range: 0.7 to 2.1) days/mm and mean bone-healing index value was 43.7 (range: 13.8 to 144) days/cm. The average lengthening achieved was 51.7 (range: 25 to 75) mm. The distraction mechanism of the nail did not function properly in two patients, restricted transient knee motion was observed in four patients, and delayed consolidation was observed in four patients. Other complications included valgus deformities and superficial infections surrounding the antenna of the intramedullary nail, as well as femur fractures at the proximal end of the nail. Bone scores were excellent in 11 segments and were good in one segment. Functional scores were excellent for all 12 patients. Conclusion: While usual complications related to the external fixators, such as pin-track infections and mobilization difficulties were not encountered, the development of additional complications such as dysfunction of the distraction mechanism should be monitored with the use of motorized intramedullary nails in limb lengthening.
引用
收藏
页码:42 / 49
页数:8
相关论文
共 32 条
[21]   Statistical analysis of axial deformity during distraction osteogenesis of the tibia [J].
Leyes, M ;
Noonan, KJ ;
Forriol, F ;
Cañadell, J .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1998, 18 (02) :190-197
[22]   Distraction osteogenesis of the lower extremity with use of monolateral external fixation -: A study of two hundred and sixty-one femora and tibiae [J].
Noonan, KJ ;
Leyes, M ;
Forriol, F ;
Cañadell, J .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (06) :793-806
[23]   Femoral lengthening over an intramedullary nail - A matched-case comparison with Ilizarov femoral lengthening [J].
Paley, D ;
Herzenberg, JE ;
Paremain, G ;
Bhave, A .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (10) :1464-1480
[24]  
PALEY D, 1990, CLIN ORTHOP RELAT R, P81
[25]   Tibial lengthening over nails in children using modified Ender nails: preliminary results of a new treatment [J].
Saraph, V ;
Roposch, A ;
Zwick, EB ;
Linhart, WE .
JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2004, 13 (06) :383-388
[26]   Fracture after distraction osteogenesis [J].
Simpson, AHRW ;
Kenwright, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (05) :659-665
[27]   Leg lengthening over an intramedullary nail [J].
Simpson, AHRW ;
Cole, AS ;
Kenwright, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (06) :1041-1045
[28]   The results of limb lengthening by callus distraction using an extending intramedullary nail (Fitbone) in non-traumatic disorders [J].
Singh, S. ;
Lahiri, A. ;
Iqbal, M. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (07) :938-942
[29]   LIMB LENGTHENING BY CALLUS DISTRACTION - COMPLICATIONS IN 53 CASES OPERATED 1980-1991 [J].
TJERNSTROM, B ;
OLERUD, S ;
REHNBERG, L .
ACTA ORTHOPAEDICA SCANDINAVICA, 1994, 65 (04) :447-455
[30]   Limb salvage using distraction osteogenesis - A classification of the technique [J].
Tsuchiya, H ;
Tomita, K ;
Minematsu, K ;
Mori, Y ;
Asada, N ;
Kitano, S .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (03) :403-411