Percutaneous image-guided implantation of totally implantable venous access ports in the forearm or the chest? A patients' point of view

被引:46
作者
Goltz, Jan Peter [1 ]
Petritsch, Bernhard [1 ]
Kirchner, Johannes [2 ]
Hahn, Dietbert [1 ]
Kickuth, Ralph [1 ]
机构
[1] Univ Wurzburg, Inst Radiol, D-97080 Wurzburg, Germany
[2] Allgemeines Krankenhaus Hagen, Dept Diagnost & Intervent Radiol, D-58095 Hagen, Germany
关键词
Central venous access; Vascular access port; Totally implantable venous access port; Patients' satisfaction; Interventional radiology; RADIOLOGICAL PLACEMENT; PATIENTS SATISFACTION; CATHETERS EVALUATION; EXPERIENCE; SYSTEMS;
D O I
10.1007/s00520-012-1544-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
This study aimed to compare patients' satisfaction and impact on daily life after implantation of totally implantable venous access ports (TIVAP) in the forearm and the chest. In this prospective study, 50 patients (mean age, 55.8 +/- 15.4 years) received three questionnaires on days 1, 30, and 90 after implantation in the forearm (n = 25) or the chest (n = 25). Knowledge concerning device function, comfort perception, and impact of TIVAP on daily activities were evaluated. Ratings were dichotomized depending on whether statements were agreed with or contradicted. Fisher's exact test was used to determine differences between the forearm port (FP) and chest port (CP) groups. There was no significant difference between the two groups with regard to unpleasant feelings (p = 0.09) and discomfort while puncturing (p = 0.06). Main fears in both groups were dysfunction and infection. The possibility of high-pressure injections via the TIVAP was rated important in both groups. More CP patients feared dislocation of their TIVAP during sleep (p < 0.05). CP patients experienced more negative perceptions while driving a car and wearing brassieres (p < 0.05) than FP patients. All patients would recommend their device. During certain activities, the FP device seems to be favorable, since it causes less discomfort than the CP.
引用
收藏
页码:505 / 510
页数:6
相关论文
共 16 条
[1]   Peripherally Placed Totally Implantable Venous-access Port Systems of the Forearm: Clinical Experience in 763 Consecutive Patients [J].
Goltz, Jan P. ;
Scholl, Anne ;
Ritter, Christian O. ;
Wittenberg, Gunther ;
Hahn, Dietbert ;
Kickuth, Ralph .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 33 (06) :1159-1167
[2]   Patients' perceptions of having a central venous catheter or a totally implantable subcutaneous port system-results from a randomised study in acute leukaemia [J].
Johansson, Eva ;
Engervall, Per ;
Bjorvell, Hjordis ;
Hast, Robert ;
Bjorkholm, Magnus .
SUPPORTIVE CARE IN CANCER, 2009, 17 (02) :137-143
[3]   Implantable vascular access systems: Experience in 1500 patients with totally implanted central venous port systems [J].
Kock, HJ ;
Pietsch, M ;
Krause, U ;
Wilke, H ;
Eigler, FW .
WORLD JOURNAL OF SURGERY, 1998, 22 (01) :12-16
[4]   Risk of deep venous thrombosis associated with chest versus arm central venous subcutaneous port catheters: A 5-year single-institution retrospective study [J].
Kuriakose, P ;
Colon-Otero, G ;
Paz-Fumagalli, R .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 13 (02) :179-184
[5]   Radiological Placement of Peripheral Central Venous Access Ports at the Forearm Technical Results and Long Term Outcome in 391 Patients [J].
Lenhart, M. ;
Schaetzler, S. ;
Manke, C. ;
Strotzer, M. ;
Seitz, J. ;
Gmeinwieser, J. ;
Voelk, M. ;
Zorger, N. ;
Feuerbach, S. ;
Herold, T. ;
Paetzel, C. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2010, 182 (01) :20-28
[6]   Central venous access ports placed by interventional radiologists: Experience with 125 consecutive patients [J].
Lorch, H ;
Zwaan, M ;
Kagel, C ;
Weiss, HD .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 24 (03) :180-184
[7]   A comparison between distal and proximal port device insertion in head and neck cancer [J].
Marcy, P. -Y. ;
Chamorey, E. ;
Amoretti, N. ;
Benezery, K. ;
Bensadoun, R. J. ;
Bozec, A. ;
Poissonnet, G. ;
Dassonville, O. ;
Rame, A. ;
Italiano, A. ;
Peyrade, F. ;
Brenac, F. ;
Gallard, J. C. .
EJSO, 2008, 34 (11) :1262-1269
[8]   Central and peripheral venous port catheters: evaluation of patients' satisfaction under local anesthesia [J].
Marcy, Pierre-Yves ;
Figl, Andrea ;
Ianessi, Antoine ;
Chamorey, Emmanuel .
JOURNAL OF VASCULAR ACCESS, 2010, 11 (02) :177-178
[9]   Radiological and surgical placement of port devices:: a 4-year institutional analysis of procedure performance, quality of life and cost in breast cancer patients [J].
Marcy, PY ;
Magné, N ;
Castadot, P ;
Bailet, C ;
Macchiavello, JC ;
Namer, M ;
Gallard, JC .
BREAST CANCER RESEARCH AND TREATMENT, 2005, 92 (01) :61-67
[10]   Central venous port catheters: evaluation of patients' satisfaction with implantation under local anesthesia [J].
Maurer, M. H. ;
Beck, A. ;
Hamm, B. ;
Gebauer, B. .
JOURNAL OF VASCULAR ACCESS, 2009, 10 (01) :27-32