Recent Tests of X-ray Spectrometers using Polycapillary optics

被引:4
|
作者
Heald, Steve [1 ]
Seidler, Gerald T. [2 ]
Mortensen, Devon [2 ]
Mattern, Brian [2 ]
Bradley, Joseph A. [3 ]
Hess, Nancy [4 ]
Bowden, Mark [4 ]
机构
[1] Argonne Natl Lab, Adv Photon Source, Argonne, IL 60439 USA
[2] Univ Washington, Dept Phys, Seattle, WA 98195 USA
[3] Lawrence Livermore Natl Lab, Livermore, CA USA
[4] Pacific Northwest Natl Lab, Richland, WA USA
来源
ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS VII | 2012年 / 8502卷
基金
加拿大自然科学与工程研究理事会;
关键词
Polycapillary; X-ray Spectroscopy; X-ray spectrometers; XAS; ELECTRONIC EXCITATIONS; CAPILLARY OPTICS; HIGH-PRESSURE; WAFERS;
D O I
10.1117/12.929960
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Polycapillary optics provide a promising approach for coupling highly-divergent x-ray emission or inelastic scattering to high-resolution crystal analyzers. We present recent results looking at the application of polycapillary collimators to emission spectrometers. The first application uses a collimating optic and a flat crystal to provide a tunable x-ray fluorescence detector. At high-flux synchrotron radiation sources there is sufficient flux (similar to 10(13) ph/sec) to allow application of X-ray Absorption Spectroscopy (XAS) to ppb concentrations if the fluorescence signal can be isolated from an intense background. The polycapillary based analyzer easily achieves the >10(6) background reduction needed for such measurements. It has the additional advantage of being confocal, only collecting the signal from a small volume at the optic focus, effectively eliminating background from sample substrates, windows, or air scattering. Second, the same type of analyzer can be used for higher-resolution emission spectroscopy if operated close to 90 degrees Bragg angle, and we report results of the commissioning of a user-available instrument suitable for few-eV resolution emission spectroscopy, including the demonstration of roughly order-of-magnitude improved measurement times compared to use of a traditional, single spherically-bent crystal analyzer. As part of this effort, we have developed a process for enhancing the integral reflectivity of Si analyzer crystals through plastic deformation at high temperatures.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Overview of polycapillary X-ray optics
    Schields, PJ
    Gibson, DM
    Gibson, WM
    Gao, N
    Huang, HP
    Ponomarev, IY
    POWDER DIFFRACTION, 2002, 17 (02) : 70 - 80
  • [2] Development of Polycapillary X-ray Optics for X-Ray Spectroscopy
    Adams, Bernhard W.
    Attenkofer, Klaus
    Bond, Justin L.
    Craven, Christopher A.
    Cremer, Till
    O'Mahony, Aileen
    Minot, Michael J.
    Popecki, Mark A.
    ADVANCES IN LABORATORY-BASED X-RAY SOURCES, OPTICS, AND APPLICATIONS V, 2016, 9964
  • [3] Development of polycapillary X-ray optics for synchrotron spectroscopy
    Popecki, Mark A.
    Bennis, Daniel
    Adams, Bernhard
    O'Mahony, Aileen
    Craven, Christopher A.
    Foley, Michael R.
    Minot, Michael J.
    Renaud, Joseph M.
    Bond, Justin L.
    Stochaj, Michael E.
    Attenkofer, Klaus
    Stavitski, Eli
    ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS X, 2015, 9588
  • [4] Energy dependence of x-ray beam size produced by polycapillary x-ray optics
    Das, Anusheela
    Heirwegh, Chris M.
    Gao, Ning
    Elam, William T.
    Wade, Lawrence A.
    Clark III, Benton C.
    Hurowitz, Joel A.
    Vanbommel, Scott J.
    Jones, Michael W. M.
    Allwood, Abigail C.
    X-RAY SPECTROMETRY, 2025, 54 (02) : 203 - 213
  • [5] Application of a polycapillary x-ray optics in high pressure XAFS
    Li, Yude
    Lin, Xiaoyan
    Liu, Shigang
    Zheng, Lirong
    He, Jinlong
    Guo, Fei
    Sun, Tianxi
    JOURNAL OF OPTICS, 2013, 15 (07)
  • [6] X-Ray Tomography of High Pressure Fuel Spray by Polycapillary Optics
    Marchitto, Luca
    Dabagov, Sultan B.
    Allocca, Luigi
    Hampai, Dariush
    Liedl, Andrea
    Alfuso, Salvatore
    ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS VIII, 2013, 8848
  • [7] Application of a new-structure polycapillary x-ray optics in high pressure
    Guo, Fei
    Lin, Xiaoyan
    Chen, Dongliang
    Liu, Shigang
    He, Jinlong
    Zhao, Weilin
    Liu, Zhiguo
    Li, Yude
    JOURNAL OF OPTICS, 2014, 16 (10)
  • [8] Experimental investigation and ray-tracing calculations on the use of polycapillary X-ray optics.
    Jans, JC
    Demichelis, MJ
    daCruz, DF
    GRAZING INCIDENCE AND MULTILAYER X-RAY OPTICAL SYSTEMS, 1997, 3113 : 484 - 493
  • [9] Effective X-ray beam size measurements of an X-ray tube and polycapillary X-ray lens system using a scanning X-ray fluorescence method
    Gherase, Mihai R.
    Vargas, Andres Felipe
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2017, 395 : 5 - 12
  • [10] Implementation of a crossed-slit system for fast alignment of sealed polycapillary X-ray optics
    Zymakova, Anna
    Prasad, Krishna Khakurel
    Picchiotti, Alessandra
    Blachucki, Wojciech
    Szlachetko, Jakub
    Rebarz, Mateusz
    Uhlig, Jens
    Andreasson, Jakob