Meeting an unmet need in glaucoma: continuous 24-h monitoring of intraocular pressure

被引:2
|
作者
Mansouri, Kaweh [1 ]
Weinreb, Robert N. [1 ]
机构
[1] Univ Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, San Diego, CA 92103 USA
关键词
24-h intraocular pressure; contact lens sensor; glaucoma; SENSIMED Triggerfish (R); CORNEAL BIOMECHANICAL PROPERTIES; OPEN-ANGLE GLAUCOMA; SELF-TONOMETRY; CONTACT-LENS; GOLDMANN TONOMETRY; TELEMETRY; THICKNESS; SENSOR; EYE; PATTERN;
D O I
10.1586/ERD.12.14
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Intraocular pressure (IOP) is a major risk factor for glaucoma and lowering IOP remains the mainstay of glaucoma treatment. Current glaucoma management usually relies on single IOP measurements during clinic hours despite the fact that the majority of glaucoma patients have their highest IOP levels outside clinic hours. The fact that these IOP peaks go largely undetected may explain why certain patients have progressive disease despite treatment. The search for devices to facilitate continuous 24-h IOP monitoring started over 50 years ago, but only recently have technological advances provided clinicians with a device for continuous IOP monitoring. We discuss the shortcomings of Goldmann Applanation Tonometry, the current gold standard for tonometry, and our experience with the SENSIMED Triggerfish (R), a telemetric contact lens sensor for 24-h IOP monitoring. It may be possible to integrate 24-h continuous IOP monitoring into clinical practice, and this has the potential to contribute to the reduction of glaucoma-related vision loss.
引用
收藏
页码:225 / 231
页数:7
相关论文
共 50 条
  • [41] The importance of and potential for continuous monitoring of intraocular pressure
    McMonnies, Charles W.
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2017, 100 (03) : 203 - 207
  • [42] Intraocular Pressure Monitoring Using an Intraocular Sensor Before and After Glaucoma Surgery
    Saxby, Edward
    Mansouri, Kaweh
    Tatham, Andrew J.
    JOURNAL OF GLAUCOMA, 2021, 30 (10) : 941 - 946
  • [43] Night-time blood pressure dipping, but not 24-h blood pressure level, is linked to increased 24-h ocular volume slope
    Skrzypecki, Janusz
    Szymanski, Fm
    Przybek-Skrzypecka, J.
    Izdebska, Justyna
    Rys-Czaporowska, A.
    Filipiak, Kj
    Szaflik, Jacek P.
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2025, 88 (01)
  • [44] Relationship of systemic blood pressure with ocular perfusion pressure and intraocular pressure of glaucoma patients in telemedical home monitoring
    Juergens, Clemens
    Grossjohann, Rico
    Tost, Frank H. W.
    MEDICAL SCIENCE MONITOR, 2012, 18 (11): : MT85 - MT89
  • [45] Comparison between Intraocular Pressure Profiles over 24 and 48 h in the Management of Glaucoma
    Keye, Philip
    Boehringer, Daniel
    Anton, Alexandra
    Reinhard, Thomas
    Luebke, Jan
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (06)
  • [46] Tolerability of 24-Hour Intraocular Pressure Monitoring of a Pressure-sensitive Contact Lens
    Lorenz, Katrin
    Korb, Christina
    Herzog, Nicola
    Vetter, Jan M.
    Elflein, Heike
    Keilani, Munir M.
    Pfeiffer, Norbert
    JOURNAL OF GLAUCOMA, 2013, 22 (04) : 311 - 316
  • [47] Inter-eye correlation analysis of 24-h IOPs and glaucoma progression
    Dakroub, Mohamad
    Verma-Fuehring, Raoul
    Agorastou, Vaia
    Schoen, Julian
    Hillenkamp, Jost
    Puppe, Frank
    Loewen, Nils A.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 260 (10) : 3349 - 3356
  • [48] Continuous Monitoring of Intraocular Pressure: An Overview of New Techniques
    Kazemi A.
    McLaren J.W.
    Sit A.J.
    Current Ophthalmology Reports, 2015, 3 (2) : 58 - 66
  • [49] Asymmetry of Habitual 24-Hour Intraocular Pressure Rhythm in Glaucoma Patients
    Liu, John H. K.
    Weinreb, Robert N.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (11) : 7398 - 7402
  • [50] Design of a Wireless Intraocular Pressure Monitoring System for a Glaucoma Drainage Implant
    Kakaday, T.
    Plunkett, M.
    McInnes, S.
    Li, J. S. Jimmy
    Voelcker, N. H.
    Craig, J. E.
    13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 198 - +