Meeting an unmet need in glaucoma: continuous 24-h monitoring of intraocular pressure

被引:2
|
作者
Mansouri, Kaweh [1 ]
Weinreb, Robert N. [1 ]
机构
[1] Univ Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, San Diego, CA 92103 USA
关键词
24-h intraocular pressure; contact lens sensor; glaucoma; SENSIMED Triggerfish (R); CORNEAL BIOMECHANICAL PROPERTIES; OPEN-ANGLE GLAUCOMA; SELF-TONOMETRY; CONTACT-LENS; GOLDMANN TONOMETRY; TELEMETRY; THICKNESS; SENSOR; EYE; PATTERN;
D O I
10.1586/ERD.12.14
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Intraocular pressure (IOP) is a major risk factor for glaucoma and lowering IOP remains the mainstay of glaucoma treatment. Current glaucoma management usually relies on single IOP measurements during clinic hours despite the fact that the majority of glaucoma patients have their highest IOP levels outside clinic hours. The fact that these IOP peaks go largely undetected may explain why certain patients have progressive disease despite treatment. The search for devices to facilitate continuous 24-h IOP monitoring started over 50 years ago, but only recently have technological advances provided clinicians with a device for continuous IOP monitoring. We discuss the shortcomings of Goldmann Applanation Tonometry, the current gold standard for tonometry, and our experience with the SENSIMED Triggerfish (R), a telemetric contact lens sensor for 24-h IOP monitoring. It may be possible to integrate 24-h continuous IOP monitoring into clinical practice, and this has the potential to contribute to the reduction of glaucoma-related vision loss.
引用
收藏
页码:225 / 231
页数:7
相关论文
共 50 条
  • [21] Continuous Monitoring of Intraocular Pressure Rationale and Progress Toward A Clinical Device
    Sit, Arthur J.
    JOURNAL OF GLAUCOMA, 2009, 18 (04) : 272 - 279
  • [22] A Wireless Pressure Sensor for Continuous Monitoring of Intraocular Pressure in Conscious Animals
    Bello, Simon A.
    Passaglia, Christopher L.
    ANNALS OF BIOMEDICAL ENGINEERING, 2017, 45 (11) : 2592 - 2604
  • [23] Transient changes in refractive error and corneal tomography after 24-h continuous monitoring of intraocular pressure patterns with a contact lens sensor
    Atsuya Miki
    Miho Kumoi
    Naoyuki Maeda
    Shizuka Koh
    Kenji Matsushita
    Kohji Nishida
    Japanese Journal of Ophthalmology, 2020, 64 : 127 - 133
  • [24] Fluctuation in Blood Pressure and Intraocular Pressure in Normal Tension Glaucoma Using Ambulatory Monitoring
    Tan, Boo Hui
    Young, Alexandra
    Bianchi, Eleonora
    Brown, Lyndsay
    Tatham, Andrew J.
    JOURNAL OF GLAUCOMA, 2021, 30 (04) : 304 - 311
  • [25] Analysis of Continuous 24-Hour Intraocular Pressure Patterns in Glaucoma
    Mansouri, Kaweh
    Liu, John H. K.
    Weinreb, Robert N.
    Tafreshi, Ali
    Medeiros, Felipe A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (13) : 8050 - 8056
  • [26] Recent progress of continuous intraocular pressure monitoring
    Xu, Jiandong
    Li, Ruisong
    Xu, Haokai
    Yang, Yi
    Zhang, Sheng
    Ren, Tian-Ling
    NANO SELECT, 2022, 3 (01): : 1 - 19
  • [27] Intraocular pressure measurements throughout the 24 h
    Bagga, Harmohina
    Liu, John H. K.
    Weinreb, Robert N.
    CURRENT OPINION IN OPHTHALMOLOGY, 2009, 20 (02) : 79 - 83
  • [28] Preliminary study on implantable inductive-type sensor for continuous monitoring of intraocular pressure
    Kim, Yong Woo
    Kim, Mi Jeung
    Park, Ki Ho
    Jeoung, Jin Wook
    Kim, Seok Hwan
    Jang, Cheol In
    Lee, Soo Hyun
    Kim, Jae Hun
    Lee, Seok
    Kang, Ji Yoon
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2015, 43 (09) : 830 - 837
  • [29] Diurnal Spikes of Intraocular Pressure in Uveitic Glaucoma: A 24-hour Intraocular Pressure Monitoring Study
    Esen, Fehim
    Eraslan, Muhsin
    Cerman, Eren
    Celiker, Hande
    Kazokoglu, Haluk
    SEMINARS IN OPHTHALMOLOGY, 2020, 35 (04) : 246 - 251
  • [30] Limited reproducibility of 24-h ambulatory blood pressure monitoring
    Keren, Shay
    Leibowitz, Avshalom
    Grossman, Ehud
    Sharabi, Yehonatan
    CLINICAL AND EXPERIMENTAL HYPERTENSION, 2015, 37 (07) : 599 - 603