Meeting an unmet need in glaucoma: continuous 24-h monitoring of intraocular pressure

被引:2
|
作者
Mansouri, Kaweh [1 ]
Weinreb, Robert N. [1 ]
机构
[1] Univ Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, San Diego, CA 92103 USA
关键词
24-h intraocular pressure; contact lens sensor; glaucoma; SENSIMED Triggerfish (R); CORNEAL BIOMECHANICAL PROPERTIES; OPEN-ANGLE GLAUCOMA; SELF-TONOMETRY; CONTACT-LENS; GOLDMANN TONOMETRY; TELEMETRY; THICKNESS; SENSOR; EYE; PATTERN;
D O I
10.1586/ERD.12.14
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Intraocular pressure (IOP) is a major risk factor for glaucoma and lowering IOP remains the mainstay of glaucoma treatment. Current glaucoma management usually relies on single IOP measurements during clinic hours despite the fact that the majority of glaucoma patients have their highest IOP levels outside clinic hours. The fact that these IOP peaks go largely undetected may explain why certain patients have progressive disease despite treatment. The search for devices to facilitate continuous 24-h IOP monitoring started over 50 years ago, but only recently have technological advances provided clinicians with a device for continuous IOP monitoring. We discuss the shortcomings of Goldmann Applanation Tonometry, the current gold standard for tonometry, and our experience with the SENSIMED Triggerfish (R), a telemetric contact lens sensor for 24-h IOP monitoring. It may be possible to integrate 24-h continuous IOP monitoring into clinical practice, and this has the potential to contribute to the reduction of glaucoma-related vision loss.
引用
收藏
页码:225 / 231
页数:7
相关论文
共 50 条
  • [1] Ambulatory 24-h intraocular pressure monitoring in the management of glaucoma
    Mansouri, Kaweh
    Weinreb, Robert N.
    CURRENT OPINION IN OPHTHALMOLOGY, 2015, 26 (03) : 214 - 220
  • [2] Systematic Review of Current Devices for 24-h Intraocular Pressure Monitoring
    Ittoop, Sabita M.
    SooHoo, Jeffrey R.
    Seibold, Leonard K.
    Mansouri, Kaweh
    Kahook, Malik Y.
    ADVANCES IN THERAPY, 2016, 33 (10) : 1679 - 1690
  • [3] 24-h monitoring devices and nyctohemeral rhythms of intraocular pressure
    Aptel, Florent
    Weinreb, Robert N.
    Chiquet, Christophe
    Mansouri, Kaweh
    PROGRESS IN RETINAL AND EYE RESEARCH, 2016, 55 : 108 - 148
  • [4] Systematic Review of Current Devices for 24-h Intraocular Pressure Monitoring
    Sabita M. Ittoop
    Jeffrey R. SooHoo
    Leonard K. Seibold
    Kaweh Mansouri
    Malik Y. Kahook
    Advances in Therapy, 2016, 33 : 1679 - 1690
  • [5] Is 24-hour Intraocular Pressure Monitoring Necessary in Glaucoma?
    Mansouri, Kaweh
    Weinreb, Robert N.
    Medeiros, Felipe A.
    SEMINARS IN OPHTHALMOLOGY, 2013, 28 (03) : 157 - 164
  • [6] Continuous 24 hour intraocular pressure monitoring for glaucoma with a contact lens sensor - time for a paradigm change
    Mansouri, Kaweh
    Weinreb, Robert N.
    SWISS MEDICAL WEEKLY, 2012, 142
  • [7] Various Ways of Continuous Intraocular Pressure Monitoring in Glaucoma Patients: A Narrative Review
    Ramakrishnan, G.
    Hamzah, Che J.
    Sharanjeet-Kaur, S.
    MEDICINE AND HEALTH-KUALA LUMPUR, 2019, 14 (02): : 17 - 29
  • [8] Mean amplitude of intraocular pressure excursions: a new assessment parameter for 24-h pressure fluctuations in glaucoma patients
    Zhai, Ruyi
    Cheng, Jingyi
    Xu, Huan
    Fang, Zhaobin
    Chen, Xu
    Qiu, Siyu
    Sun, Xinghuai
    Lee, Richard K.
    Xiao, Ming
    Kong, Xiangmei
    EYE, 2021, 35 (01) : 326 - 333
  • [9] Diurnal and 24-h Intraocular Pressures in Glaucoma: Monitoring Strategies and Impact on Prognosis and Treatment
    Konstas, Anastasios G.
    Kahook, Malik Y.
    Araie, Makoto
    Katsanos, Andreas
    Quaranta, Luciano
    Rossetti, Luca
    Hollo, Gabor
    Detorakis, Efstathios T.
    Oddone, Francesco
    Mikropoulos, Dimitrios G.
    Dutton, Gordon N.
    ADVANCES IN THERAPY, 2018, 35 (11) : 1775 - 1804
  • [10] Advances in diagnostic applications for monitoring intraocular pressure in Glaucoma: A review
    Sanchez, Irene
    Martin, Raul
    JOURNAL OF OPTOMETRY, 2019, 12 (04) : 211 - 221