Strength of Circular Concrete-Filled Tubes with and without Internal Reinforcement under Combined Loading

被引:47
作者
Moon, Jiho [1 ]
Lehman, Dawn E. [2 ]
Roeder, Charles W. [2 ]
Lee, Hak-Eun [1 ]
机构
[1] Korea Univ, Seoul 136701, South Korea
[2] Univ Washington, Dept Civil & Environm Engn, Seattle, WA 98195 USA
关键词
Tubes; Composite materials; Structural design; Buckling; Finite element method; Load factors; Concrete-filled tubes (CFTs); Composite behavior; P-M interaction curve; Nonlinear finite-element analysis; Metal and composite structures; PLASTIC-DAMAGE MODEL; DESIGN PROVISIONS; BEHAVIOR; COLUMNS; BEAMS;
D O I
10.1061/(ASCE)ST.1943-541X.0000788
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Concrete-filled tubes (CFTs) have been used in civil engineering practice as piles, caissons, columns, and bridge piers. Relative to conventional structural steel and reinforced concrete components, CFTs have several advantages. The steel tube serves as both reinforcement and formwork, eliminating the need for both, and provides large tensile and compressive capacities; the concrete fill restrains buckling of the steel tube, which increases the strength, stiffness, and deformability of the section. In some cases, internal reinforcement is used to enhance the strength and facilitate connection to adjacent members. Although these properties are well accepted, the use of CFTs in practice is awkward because design provisions among codes vary significantly and previous research has not considered internal reinforcement. An analytical research study was undertaken to evaluate and improve design provisions for CFTs with and without internal reinforcement under combined axial load and bending. A continuum model was developed to simulate prior test results subjected to combined loading and the validated model was used to investigate the strength and inelastic performance of CFTs under combined loading. Current design provisions for CFTs were evaluated using the results of these finite-element analysis and previous test results. The comparisons indicate that current design approach provides good prediction of CFT capacity subjected only to bending or axial demands, but current provisions provide conservative values for the CFTs under general combined loading. An alternative P-M interaction curve for CFTs was proposed.
引用
收藏
页数:12
相关论文
共 31 条
[1]  
[Anonymous], 2008, Building code requirements for structural concrete and commentary
[2]  
[Anonymous], ABAQUS COMP SOFTW
[3]  
[Anonymous], 2010, AISC 360-10
[4]  
[Anonymous], 2009, AASHTO LRFD BRIDG DE, V4th
[5]  
Bishop E. S, 2009, THESIS U WASHINGTON
[6]   Slenderness limits for filled circular steel tubes [J].
Bradford, MA ;
Loh, HY ;
Uy, B .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2002, 58 (02) :243-252
[7]   Seismic Design of Concrete-Filled Circular Steel Bridge Piers [J].
Bruneau, Michel ;
Marson, Julia .
JOURNAL OF BRIDGE ENGINEERING, 2004, 9 (01) :24-34
[8]  
CEN, 2004, 199411 CEN EN
[9]   New approach to AISC P-M interaction curve for square concrete filled tube (CFT) beam-columns [J].
Choi, Young-Hwan ;
Foutch, Douglas A. ;
LaFave, James M. .
ENGINEERING STRUCTURES, 2006, 28 (11) :1586-1598
[10]   Concrete-filled circular steel tubes subjected to pure bending [J].
Elchalakani, M ;
Zhao, XL ;
Grzebieta, RH .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2001, 57 (11) :1141-1168