The Study on Influence Factors of the Mechanical Smoke Evacuation System in Atrium Buildings

被引:4
作者
Xu Jun-bin [1 ]
Zhang Cheng [1 ]
Zhao Jun-fei [2 ]
Chen Qing-quan [1 ]
Wu Jia-bao [1 ]
机构
[1] Chinese Peoples Armed Police Force Acad, Langfang 065000, Peoples R China
[2] Jinhua Fire Detachment Zhejiang Gen Fire Brigade, Yiwu 322000, Peoples R China
来源
2012 INTERNATIONAL CONFERENCE ON PERFORMANCE-BASED FIRE AND FIRE PROTECTION ENGINEERING | 2013年 / 52卷
关键词
atrium building; smoke evacuation quantity; shape coefficient; exhaust fan start-up time; fire load;
D O I
10.1016/j.proeng.2013.02.176
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper starts from the structure features and fire characteristics of an atrium building, and clarifies the importance of the mechanical smoke extraction system. The disadvantages of China's code about the smoke control system design in an atrium are analyzed. The influencing factors of the smoke removal efficiency is studied in this paper including smoke evacuation quantity, atrium shape coefficient, smoke exhaust this start-up time and heat release rate.The future research direction is put forward according to the conclusion. (C) 2013 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:508 / 513
页数:6
相关论文
共 8 条
[1]  
[Anonymous], GB50045952005
[2]  
[Anonymous], NFPA92B
[3]  
[Anonymous], DGJ08882008
[4]   ON THE SIMULATION OF ATRIUM FIRE ENVIRONMENT IN HONG-KONG USING ZONE MODELS [J].
CHOW, WK ;
WONG, WK .
JOURNAL OF FIRE SCIENCES, 1993, 11 (01) :3-51
[5]  
Eng P., ASHRAE T S
[6]  
Hinkley P.L., 1988, SFPE HDB FIRE PROTEC
[7]  
Zhang C.F., 2005, FIRE SCI TECHNOLOGY, V24, P153
[8]  
Zhao Shengping, 2002, COMPUTER SIMULATION