Projecting LED product life based on application

被引:11
作者
Narendran, Nadarajah [1 ]
Liu, Yi-wei [1 ]
Mou, Xi [1 ]
Thotagamuwa, Dinusha R. [1 ]
Eshwarage, Oshadhi V. Madihe [1 ]
机构
[1] Rensselaer Polytech Inst, Lighting Res Ctr, 21 Union St, Troy, NY 12180 USA
来源
FIFTEENTH INTERNATIONAL CONFERENCE ON SOLID STATE LIGHTING AND LED-BASED ILLUMINATION SYSTEMS | 2016年 / 9954卷
关键词
LED; system life; SSL; life test; catastrophic failure; parametric failure; lumen depreciation;
D O I
10.1117/12.2240464
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
LED products have started to displace traditional light sources in many lighting applications. One of the commonly claimed benefits for LED lighting products is their long useful lifetime in applications. Today there are many replacement lamp products using LEDs in the marketplace. Typically, lifetime claims of these replacement lamps are in the 25,000-hour range. According to current industry practice, the time for the LED light output to reach the 70% value is estimated according to IESNA LM-80 and TM-21 procedures and the resulting value is reported as the whole system life. LED products generally experience different thermal environments and switching (on-off cycling) patterns when used in applications. Current industry test methods often do not produce accurate lifetime estimates for LED systems because only one component of the system, namely the LED, is tested under a continuous-on burning condition without switching on and off, and because they estimate for only one failure type, lumen depreciation. The objective of the study presented in this manuscript was to develop a test method that could help predict LED system life in any application by testing the whole LED system, including on-off power cycling with sufficient dwell time, and considering both failure types, catastrophic and parametric. The study results showed for the LED A-lamps tested in this study, both failure types, catastrophic and parametric, exist. The on-off cycling encourages catastrophic failure, and maximum operating temperature influences the lumen depreciation rate and parametric failure time. It was also clear that LED system life is negatively affected by on-off switching, contrary to commonly held belief. In addition, the study results showed that most of the LED systems failed catastrophically much ahead of the LED light output reaching the 70% value. This emphasizes the fact that life testing of LED systems must consider catastrophic failure in addition to lumen depreciation, and the shorter of the two failure modes must be selected as the system life. The results of this study show a shorter time test procedure can be developed to accurately predict LED system life in any application by knowing the LED temperature and the switching cycle.
引用
收藏
页数:8
相关论文
共 12 条
[1]  
[Anonymous], LM8008 IES
[2]  
[Anonymous], LM8414 IES
[3]  
Cail M, 2012, 2012 13 INT C EL PAC, DOI [10.1109/ICEPT-HDP.2012.6474926, DOI 10.1109/ICEPT-HDP.2012.6474926]
[4]   Failure causes and mechanisms of retrofit LED lamps [J].
De Santi, C. ;
Dal Lago, M. ;
Buffolo, M. ;
Monti, D. ;
Meneghini, M. ;
Meneghesso, G. ;
Zanoni, E. .
MICROELECTRONICS RELIABILITY, 2015, 55 (9-10) :1765-1769
[5]  
Hao J, 2016, 2016 17TH INTERNATIONAL CONFERENCE ON THERMAL, MECHANICAL AND MULTI-PHYSICS SIMULATION AND EXPERIMENTS IN MICROELECTRONICS AND MICROSYSTEMS (EUROSIME)
[6]  
IES Testing Procedures Committee, 2011, PROJ LONG TERM LUM M
[7]  
Narendran N., 2014, STRATEGIES LIGHT 201
[8]  
Narendran N., 2015, DIGEST TECHNICAL PAP
[9]  
Next Generation Lighting Inustry Alliance and LED Systems Reliability Consortium, 2014, LED LUM LIF REC TEST
[10]  
Shinohara Kazunori, 2010, Engineering, V2, P1006, DOI 10.4236/eng.2010.212127