Development of a diagnostic method for Parkinson's disease by reverse-phase high-performance liquid chromatography coupled with integrated pulsed amperometric detection

被引:16
|
作者
Oh, Minhwa [1 ]
Huh, Eugene [2 ,3 ]
Oh, Myung Sook [3 ,4 ,5 ]
Jeong, Ji-Seon [6 ,7 ]
Hong, Seon-Pyo [1 ,4 ,5 ]
机构
[1] Kyung Hee Univ, Grad Sch, Dept Oriental Pharmaceut Sci, 26 Kyungheeedae Ro, Seoul 02447, South Korea
[2] Kyung Hee Univ, Grad Sch, Dept Sci Korean Med, 26 Kyungheeedae Ro, Seoul 02447, South Korea
[3] Kyung Hee Univ, Grad Sch, Dept Life & Nanopharmaceut Sci, 26 Kyungheeedae Ro, Seoul 02447, South Korea
[4] Kyung Hee Univ, Dept Oriental Pharmaceut Sci, Coll Pharm, 26 Kyungheeedae Ro, Seoul 02447, South Korea
[5] Kyung Hee Univ, Kyung Hee East West Pharmaceut Res Inst, 26 Kyungheeedae Ro, Seoul 02447, South Korea
[6] Korea Res Inst Stand & Sci, Dept Metrol Qual Life, Ctr Bioanal, 267 Gajeong Ro, Daejeon 34113, South Korea
[7] Univ Sci & Technol, Dept Bioanalyt Sci, 217 Gajeong Ro, Daejeon 34113, South Korea
关键词
Mice striatum; Parkinson's disease; Dopamine; 3,4-dihydroxyphenylacetic acid; Serotonin; 5-hydroxyindolacetic acid; Homovanillic acid; Integrated pulsed amperometric detection; Direct method; Biomarker; TANDEM MASS-SPECTROMETRY; ELECTROCHEMICAL DETECTION; BIOGENIC-AMINES; HUMAN PLASMA; DOPAMINE; HPLC; NOREPINEPHRINE; SEPARATION; LEVODOPA; 3-O-METHYLDOPA;
D O I
10.1016/j.jpba.2018.02.025
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We developed a diagnostic method for Parkinson's disease by simultaneously analyzing biogenic amines and their metabolites using reverse-phase high-performance liquid chromatography coupled with integrated pulsed amperometric detection (RP-HPLC-IPAD) method. Dopamine (DA), 3, 4-dihydroxyphenylacetic acid (DOPAC), serotonin (5-HT), 5-hydroxyindolacetic acid (5-HIAA), and homovanillic acid (HVA) were used as biomarkers to diagnose Parkinson's disease. All target components were detected with good sensitivity using sodium hydroxide (as a post-column eluent). The limit of detection (S/N = 3) and limit of quantification (S/N = 10) of the target components ranged from 0.020 to 2.400 ng and from 0.080 to 8.000 ng, respectively. The coefficients of linear regression ranged from 0.9996 to 1.0000, all inter-day and intra-day precision values were <3.43%, and the average recovery and RSD ranged from 97.55 to 103.60% and 0.22 to 4.79% for mice striatum samples. This method exhibited good selectivity, sensitivity, and reproducibility and can be used directly without any pretreatment steps. Our method will be useful as a tool to diagnose Parkinson's disease. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:110 / 116
页数:7
相关论文
共 50 条