Development of a diagnostic method for Parkinson's disease by reverse-phase high-performance liquid chromatography coupled with integrated pulsed amperometric detection

被引:16
|
作者
Oh, Minhwa [1 ]
Huh, Eugene [2 ,3 ]
Oh, Myung Sook [3 ,4 ,5 ]
Jeong, Ji-Seon [6 ,7 ]
Hong, Seon-Pyo [1 ,4 ,5 ]
机构
[1] Kyung Hee Univ, Grad Sch, Dept Oriental Pharmaceut Sci, 26 Kyungheeedae Ro, Seoul 02447, South Korea
[2] Kyung Hee Univ, Grad Sch, Dept Sci Korean Med, 26 Kyungheeedae Ro, Seoul 02447, South Korea
[3] Kyung Hee Univ, Grad Sch, Dept Life & Nanopharmaceut Sci, 26 Kyungheeedae Ro, Seoul 02447, South Korea
[4] Kyung Hee Univ, Dept Oriental Pharmaceut Sci, Coll Pharm, 26 Kyungheeedae Ro, Seoul 02447, South Korea
[5] Kyung Hee Univ, Kyung Hee East West Pharmaceut Res Inst, 26 Kyungheeedae Ro, Seoul 02447, South Korea
[6] Korea Res Inst Stand & Sci, Dept Metrol Qual Life, Ctr Bioanal, 267 Gajeong Ro, Daejeon 34113, South Korea
[7] Univ Sci & Technol, Dept Bioanalyt Sci, 217 Gajeong Ro, Daejeon 34113, South Korea
关键词
Mice striatum; Parkinson's disease; Dopamine; 3,4-dihydroxyphenylacetic acid; Serotonin; 5-hydroxyindolacetic acid; Homovanillic acid; Integrated pulsed amperometric detection; Direct method; Biomarker; TANDEM MASS-SPECTROMETRY; ELECTROCHEMICAL DETECTION; BIOGENIC-AMINES; HUMAN PLASMA; DOPAMINE; HPLC; NOREPINEPHRINE; SEPARATION; LEVODOPA; 3-O-METHYLDOPA;
D O I
10.1016/j.jpba.2018.02.025
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We developed a diagnostic method for Parkinson's disease by simultaneously analyzing biogenic amines and their metabolites using reverse-phase high-performance liquid chromatography coupled with integrated pulsed amperometric detection (RP-HPLC-IPAD) method. Dopamine (DA), 3, 4-dihydroxyphenylacetic acid (DOPAC), serotonin (5-HT), 5-hydroxyindolacetic acid (5-HIAA), and homovanillic acid (HVA) were used as biomarkers to diagnose Parkinson's disease. All target components were detected with good sensitivity using sodium hydroxide (as a post-column eluent). The limit of detection (S/N = 3) and limit of quantification (S/N = 10) of the target components ranged from 0.020 to 2.400 ng and from 0.080 to 8.000 ng, respectively. The coefficients of linear regression ranged from 0.9996 to 1.0000, all inter-day and intra-day precision values were <3.43%, and the average recovery and RSD ranged from 97.55 to 103.60% and 0.22 to 4.79% for mice striatum samples. This method exhibited good selectivity, sensitivity, and reproducibility and can be used directly without any pretreatment steps. Our method will be useful as a tool to diagnose Parkinson's disease. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:110 / 116
页数:7
相关论文
共 50 条
  • [21] Simultaneous diagnostic method for phenylketonuria and galactosemia from dried blood spots using high-performance liquid chromatography-pulsed amperometric detection
    Kim, Nam-Hee
    Jeong, Ji-Seon
    Kwon, Ha-Jeong
    Lee, Yong-Moon
    Yoon, Hye-Ran
    Lee, Young Ryul
    Hong, Seon-Pyo
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (21): : 1860 - 1864
  • [22] Direct determination of tryptophan using high-performance anion-exchange chromatography with integrated pulsed amperometric detection
    Hanko, VP
    Rohrer, JS
    ANALYTICAL BIOCHEMISTRY, 2002, 308 (02) : 204 - 209
  • [23] Establishment of a Rapid and Highly Sensitive Reverse-phase High-performance Liquid Chromatography Based Analytical Assay Method for Duvelisib
    Sonawane, Dipali
    Sahu, Amit Kumar
    Jadav, Tarang
    Sengupta, Pinaki
    INDIAN JOURNAL OF PHARMACEUTICAL EDUCATION AND RESEARCH, 2022, 56 (01) : 287 - 295
  • [24] Sensitive determination of nitrophenol isomers by reverse-phase high-performance liquid chromatography in conjunction with liquid-liquid extraction
    Boddu, Veera
    Kim, Sanghoon
    Adkins, Jason
    Weimer, Ellyn
    Paul, Tias
    Damavarapu, Reddy
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2017, 97 (11) : 1053 - 1064
  • [25] Reverse-phase high-performance liquid chromatography for the simultaneous determination of sildenafil and N-desmethyl sildenafil in plasma of children
    Goffredo, Bianca Maria
    Cairoli, Sara
    Vitale, Alessia
    Corsetti, Tiziana
    Pastore, Anna
    BIOMEDICAL CHROMATOGRAPHY, 2016, 30 (12) : 2070 - 2073
  • [26] Identification of plastoquinone-C in spinach and maple leaves by reverse-phase high-performance liquid chromatography
    Kruk, J
    Strzalka, H
    PHYTOCHEMISTRY, 1998, 49 (08) : 2267 - 2271
  • [27] Separation and Estimation of Process-Related Impurities of Gefitinib by Reverse-Phase High-Performance Liquid Chromatography
    Chandrashekara, Karunakara A.
    Udupi, Aparna
    Reddy, Chandrasekara G.
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2014, 52 (08) : 799 - 805
  • [28] Determination of tobramycin and impurities using high-performance anion exchange chromatography with integrated pulsed amperometric detection
    Hanko, VP
    Rohrer, JS
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 40 (04) : 1006 - 1012
  • [29] Indirect pulsed electrochemical detection following high-performance reversed-phase liquid chromatography
    Keating, Loryn R.
    LaCourse, William R.
    TALANTA, 2019, 199 : 155 - 163
  • [30] Characterisation of brewpub beer carbohydrates using high performance anion exchange chromatography coupled with pulsed amperometric detection
    Arfelli, Giuseppe
    Sartini, Elisa
    FOOD CHEMISTRY, 2014, 142 : 152 - 158