Effect of sterilization processes on the properties of a silane hybrid coating applied to Ti6Al4V alloy

被引:9
作者
Kerstner Baldin, Estela K. [1 ]
Garcia, Charlene [2 ]
Henriques, Joao Antonio P. [2 ]
Ely, Mariana Roesch [2 ]
Birriel, Eliena Jonko [3 ]
Brandalise, Rosmary Nichele [3 ]
Malfatti, Celia de Fraga [1 ]
机构
[1] Univ Rio Grande do Sul UFRGS, Res Lab Corros LAPEC, BR-9500 Porto Alegre, RS, Brazil
[2] UCS, Lab Genom Prote & DNA Repair, BR-1130 Caxias Do Sul, RS, Brazil
[3] UCS, Postgrad Program Proc & Technol Engn, BR-1130 Caxias Do Sul, RS, Brazil
关键词
SOL-GEL COATINGS; GRADE STAINLESS-STEEL; IN-VITRO; BIOACTIVE PARTICLES; SURFACE CHARACTERISTICS; BIOMEDICAL APPLICATIONS; CORROSION-RESISTANCE; TITANIUM SURFACES; CELL-ADHESION; IMPLANTS;
D O I
10.1557/jmr.2017.429
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Sterilization is one of the last stages prior to the implantation of a biomaterial. Therefore, the method should be chosen carefully as this is determinant not to compromise the properties of the material. In this context, three sterilization processes were evaluated as to their effect on the properties of a silane hybrid coating: steam autoclave, ethylene oxide, and hydrogen peroxide plasma. The coating was obtained from a sol consisting of alkoxysilane Tetraethoxysilane and organoalcoxysilane Methyltriethoxysilane (MTES), applied to the Ti6Al4V substrate, to increase its corrosion resistance and biocompatibility. After sterilization, the samples were characterized by scanning electron microscopy, atomic force microscopy, profilometry, wetabillity, and Fourier transform infrared spectroscopy. The electrochemical behavior was monitored by open circuit potential and potentiodynamic polarization curves. The cytocompatibility was evaluated by adhesion, viability, and morphological alterations in the MG-63 cells. The results showed that the protective behavior of the hybrid coating was compromised regardless of the sterilization method. However, the steam autoclave caused more morphological changes on the silane hybrid coating as well as on the Ti6Al4V substrate than the other two sterilization methods. Although the sterilized hybrid coating did not show cytotoxicity, the hybrid coating sterilized by hydrogen peroxide plasma showed a higher percentage of viable cells. The ethylene oxide presented the lowest percentage of viability and the highest cell death rate.
引用
收藏
页码:161 / 177
页数:17
相关论文
共 69 条
[1]  
ALLEY MC, 1988, CANCER RES, V48, P589
[2]   A review of hydroxyapatite-based coating techniques: Sol-gel and electrochemical depositions on biocompatible metals [J].
Asri, R. I. M. ;
Harun, W. S. W. ;
Hassan, M. A. ;
Ghani, S. A. C. ;
Buyong, Z. .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2016, 57 :95-108
[3]   Ammonium molybdate added in hybrid films applied on tinplate: Effect of the concentration in the corrosion inhibition action [J].
Baldin, Estela K. K. ;
Kunst, Sandra R. ;
Beltrami, Lilian V. R. ;
Lemos, Tiago M. ;
Quevedo, Marcela C. ;
Bastos, Alexandre C. ;
Ferreira, Mario G. S. ;
Santos, Paulo R. R. ;
Sarmento, Victor H. V. ;
Malfatti, Celia de F. .
THIN SOLID FILMS, 2016, 600 :146-156
[4]   Electrochemical evaluation of multilayer silica-metacrylate hybrid sol-gel coatings containing bioactive particles on surgical grade stainless steel [J].
Ballarre, Josefina ;
Lopez, Damian A. ;
Rosero, Nataly C. ;
Duran, Alicia ;
Aparicio, Mario ;
Cere, Silvia M. .
SURFACE & COATINGS TECHNOLOGY, 2008, 203 (1-2) :80-86
[5]   Protective hybrid sol-gel coatings containing bioactive particles on surgical grade stainless steel:: Surface characterization [J].
Ballarre, Josefina ;
Lopez, Damian A. ;
Schreiner, Wido H. ;
Duran, Alicia ;
Cere, Silvia M. .
APPLIED SURFACE SCIENCE, 2007, 253 (17) :7260-7264
[6]   Morphologic and nanomechanical characterization of bone tissue growth around bioactive sol-gel coatings containing wollastonite particles applied on stainless steel implants [J].
Ballarre, Josefina ;
Seltzer, Rocio ;
Mendoza, Emigdio ;
Carlos Orellano, Juan ;
Mai, Yiu-Wing ;
Garcia, Claudia ;
Cere, Silvia M. .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2011, 31 (03) :545-552
[7]   Improving the osteointegration and bone-implant interface by incorporation of bioactive particles in sol-gel coatings of stainless steel implants [J].
Ballarre, Josefina ;
Manjubala, Inderchand ;
Schreiner, Wido H. ;
Carlos Orellano, Juan ;
Fratzl, Peter ;
Cere, Silvia .
ACTA BIOMATERIALIA, 2010, 6 (04) :1601-1609
[8]   THE EFFECT OF EO AND STEAM STERILIZATION ON THE MECHANICAL AND ELECTROCHEMICAL PROPERTIES OF TITANIUM GRADE 4 [J].
Basiaga, Marcin ;
Walke, Witold ;
Paszenda, Zbigniew ;
Kajzer, Anita .
MATERIALI IN TEHNOLOGIJE, 2016, 50 (01) :153-158
[9]   Evaluating structural and microstructural changes of PDMS-SiO2 hybrid materials after sterilization by gamma irradiation [J].
Carlos Almeida, J. ;
Lancastre, Joana ;
Helena Vaz Fernandes, M. ;
Margaca, Fernanda M. A. ;
Ferreira, Luis ;
Miranda Salvado, Isabel M. .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 48 :354-358
[10]   Morphology and performances of the anodic oxide films on Ti6Al4V alloy formed in alkaline-silicate electrolyte with aminopropyl silane addition under low potential [J].
Chen, Jiali ;
Wang, Jinwei ;
Yuan, Hongye .
APPLIED SURFACE SCIENCE, 2013, 284 :900-906