Feasibility study of using simultaneous multi-slice RESOLVE diffusion weighted imaging to assess parotid gland tumors: comparison with conventional RESOLVE diffusion weighted imaging

被引:13
作者
Jiang, Jia-Suo [1 ]
Zhu, Liu-Ning [2 ]
Wu, Qian [1 ]
Sun, Yi [3 ]
Liu, Wei [4 ]
Xu, Xiao-Quan [1 ]
Wu, Fei-Yun [1 ]
机构
[1] Nanjing Med Univ, Affiliated Hosp 1, Dept Radiol, 300 Guangzhou Rd, Nanjing, Peoples R China
[2] Nanjing Med Univ, Affiliated Hosp 1, Dept Stomatol, Nanjing, Peoples R China
[3] Siemens Healthcare Ltd, MR Collaborat, Shanghai, Peoples R China
[4] Siemens Shenzhen Magnet Resonance Ltd, Shenzhen, Peoples R China
关键词
Parotid gland; Magnetic resonance imaging; Diffusion-weighted imaging; Readout segmentation of long variable echo-trains; Simultaneous multi-slice; ECHO; QUALITY; RESOLUTION; IMPROVES;
D O I
10.1186/s12880-020-00492-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background To evaluate the feasibility of using simultaneous multi-slice (SMS) readout segmentation of long variable echo-trains (RESOLVE) diffusion-weighted imaging (DWI) to assess parotid gland tumors, compared with conventional RESOLVE DWI. Methods From September 2018 to December 2018, 20 consecutive patients with parotid tumors who underwent MRI scan for pre-surgery evaluation were enrolled. SMS-RESOLVE DWI and conventional RESOLVE DWI were scanned with matched imaging parameters, respectively. The scan time of two DWI sequences was recorded. Qualitative (anatomical structure differentiation, lesion display, artifact, and overall image quality) and quantitative (apparent diffusion coefficient, ADC; ratio of signal-to-noise ratio, SNR ratio; ratio of contrast-to-noise ratio, CNR ratio) assessments of image quality were performed, and compared between SMS-RESOLVE DWI and conventional RESOLVE DWI by using Pairedt-test. Two-sidedPvalue less than 0.05 indicated significant difference. Results The scan time was 3 min and 41 s for SMS-RESOLVE DWI, and 5 min and 46 s for conventional RESOLVE DWI. SMS-RESOLVE DWI produced similar qualitative image quality with RESOLVE DWI (anatomical structure differentiation,P = 0.164; lesion display,P = 0.193; artifact,P = 0.330; overall image quality,P = 0.083). Meanwhile, there were no significant difference on ADC(Lesion)(P = 0.298), ADC(Masseter)(P = 0.122), SNR ratio (P = 0.584) and CNR ratio (P = 0.217) between two DWI sequences. Conclusion Compared with conventional RESOLVE DWI, SMS-RESOLVE DWI could provide comparable image quality using markedly reduced scan time. SMS could increase the clinical usability of RESOLVE technique for DWI of parotid gland.
引用
收藏
页数:8
相关论文
共 25 条
[1]   Simultaneous multi-slice accelerated turbo spin echo of the knee in pediatric patients [J].
Benali, Sebastien ;
Johnston, Patrick R. ;
Gholipour, Ali ;
Dugan, Monet E. ;
Heberlein, Keith ;
Bhat, Himanshu ;
Bixby, Sarah D. .
SKELETAL RADIOLOGY, 2018, 47 (06) :821-831
[2]   Bilateral Diffusion-weighted MR Imaging of Breast Tumors with Submillimeter Resolution Using Readout-segmented Echoplanar Imaging at 7 T [J].
Bogner, Wolfgang ;
Pinker, Katja ;
Zaric, Olgica ;
Baltzer, Pascal ;
Minarikova, Lenka ;
Porter, David ;
Bago-Horvath, Zsuzsanna ;
Dubsky, Peter ;
Helbich, Thomas H. ;
Trattnig, Siegfried ;
Gruber, Stephan .
RADIOLOGY, 2015, 274 (01) :74-84
[3]   Readout-segmented Echo-pIanar Imaging Improves the Diagnostic Performance of Diffusion-weighted MR Breast Examinations at 3.0 T [J].
Bogner, Wolfgang ;
Pinker-Domenig, Katja ;
Bickel, Hubert ;
Chmelik, Marek ;
Weber, Michael ;
Helbich, Thomas H. ;
Trattnig, Siegfried ;
Gruber, Stephan .
RADIOLOGY, 2012, 263 (01) :64-76
[4]   Simultaneous multi-slice echo planar diffusion weighted imaging of the liver and the pancreas: Optimization of signal-to-noise ratio and acquisition time and application to intravoxel incoherent motion analysis [J].
Boss, Andreas ;
Barth, Borna ;
Filli, Lukas ;
Kenkel, David ;
Wurnig, Moritz C. ;
Piccirelli, Marco ;
Reiner, Caecilia S. .
EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (11) :1948-1955
[5]   Improved Spatiotemporal Resolution of Dynamic Susceptibility Contrast Perfusion MRI in Brain Tumors Using Simultaneous Multi-Slice Echo-Planar Imaging [J].
Chakhoyan, A. ;
Leu, K. ;
Pope, W. B. ;
Cloughesy, T. F. ;
Ellingson, B. M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2018, 39 (01) :43-45
[6]   Diffusion-Weighted Imaging in Head and Neck Cancer Technique, Limitations, and Applications [J].
Connolly, Michael ;
Srinivasan, Ashok .
MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2018, 26 (01) :121-+
[7]   Simultaneous multi-slice readout-segmented echo planar imaging for accelerated diffusion-weighted imaging of the breast [J].
Filli, Lukas ;
Ghafoor, Soleen ;
Kenkel, David ;
Liu, Wei ;
Weiland, Elisabeth ;
Andreisek, Gustav ;
Frauenfelder, Thomas ;
Runge, Val M. ;
Boss, Andreas .
EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (01) :274-278
[8]   Simultaneous multi-slice MR imaging of the hip at 3T to reduce acquisition times and maintain image quality [J].
Haraikawa, Mayuko ;
Suzuki, Masashi ;
Inoue, Kaiji ;
Kozawa, Eito ;
Tanaka, Junji ;
Niitsu, Mamoru .
BMC MUSCULOSKELETAL DISORDERS, 2018, 19
[9]   Comparison of simultaneous multi-slice readout-segmented EPI and conventional single-shot EPI for diffusion tensor imaging of the ulnar nerve [J].
Ho, Michael ;
Becker, Anton ;
Ulbrich, Erika ;
Manoliu, Andrei ;
Kuhn, Felix P. ;
Eberhard, Matthias ;
Filli, Lukas .
HELIYON, 2018, 4 (10)
[10]   Simultaneous multi-slice inverse imaging of the human brain [J].
Hsu, Yi-Cheng ;
Chu, Ying-Hua ;
Tsai, Shang-Yueh ;
Kuo, Wen-Jui ;
Chang, Chun-Yuan ;
Lin, Fa-Hsuan .
SCIENTIFIC REPORTS, 2017, 7